Polymeric Piezoelectric Transducers for Hydrophone Applications

Conventional ceramic piezoelectric materials have been used in hydrophones for sonarapplications since 1940's. In the last few years since the discovery of polymeric piezoelectrichydrophones, the technology has matured, applications have emerged in extraordinary number ofcases such as underwater navigation, biomedical applications, biomimetics, etc. Hydrophones areused underwater at high hydrostatic pressures. In the presence of hydrostatic pressures, theanisotropic piezoelectric response of ceramic materials is such that it has poor hydrophone performancecharacteristics whereas polymeric piezoelectric materials show enough hydrostatic piezoelectriccoefficients. Moreover, piezoelectric polymers have low acoustic impedance, which is only 2-6 timethat of water, whereas in piezoelectric ceramics, it is typically 11-time greater than that of water. Aclose impedance match permits efficient transduction of acoustic signals in water and tissues. Newlydeveloped hydrostatic-mode polyvinylidene flouride (PVDF) hydrophones use a pressure-releasesystem to achieve improved sensitivity. Recently, voided PVDF materials have been used for makinghydrophones having higher sensitivity and figure of merit than unvoided PVDF materials.

[1]  F. Perennes,et al.  Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  Q X Chen,et al.  Industrial applications of piezoelectric polymer transducers , 1995 .

[3]  B. Woodward,et al.  Underwater Acoustic Measurements on Polyvinylidene Fluoride Transducers , 1978 .

[4]  J E Saunders,et al.  Acoustic performance and clinical use of a fibreoptic hydrophone. , 1998, Ultrasound in medicine & biology.

[5]  J. W. Young Optimization of acoustic receiver noise performance , 1977 .

[6]  H. Kawai,et al.  The Piezoelectricity of Poly (vinylidene Fluoride) , 1969 .

[7]  D. Ricketts Electroacoustic sensitivity of composite piezoelectric polymer cylinders , 1980 .

[8]  Yasuhiro Nakamura,et al.  Study of surface elastic wave induced on backing material and diffracted field of a piezoelectric polymer film hydrophone , 1993 .

[9]  S. Koshigoe,et al.  A new approach for active control of sound transmission through an elastic plate backed by a rectangular cavity , 1993 .

[10]  Kentaro Nakamura,et al.  Pressure Sensitivity of a Fiber-Optic Microprobe for High-Frequency Ultrasonic Field , 1999 .

[11]  David T. Wilson,et al.  PVF 2 Polymer Microprobe , 1979 .

[12]  G. R. Harris,et al.  Sensitivity Considerations for PVDF Hydrophones Using the Spot-Poled Membrane Design , 1982, IEEE Transactions on Sonics and Ultrasonics.

[13]  Charles Maerfeld,et al.  PVF2 velocity hydrophones , 1985 .

[14]  Snehashish Chakraverty,et al.  Vibration of Plates , 2008 .

[15]  M. Platte,et al.  A polyvinylidene fluoride needle hydrophone for ultrasonic applications , 1985 .

[16]  Mark B. Moffett A ?c hydrophone , 1985 .

[17]  P. A. Lewin,et al.  Miniature piezoelectric polymer ultrasonic hydrophone probes , 1981 .

[18]  P. Beard,et al.  Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  K. T. Chung,et al.  Piezoelectric and pyroelectric properties of poly(vinylidene fluoride) films at high hydrostatic pressure , 1981 .

[20]  V. Wilkens,et al.  Fiber-optic multilayer hydrophone for ultrasonic measurement , 1999 .

[21]  P A Lewin,et al.  Beyond 40 MHz frontier: the future technologies for calibration and sensing of acoustic fields , 2004 .

[22]  Seymour Edelman,et al.  Piezoelectric polymer probe for ultrasonic applications , 1981 .

[23]  G. Corcos Resolution of Pressure in Turbulence , 1963 .

[24]  Ralph S. Woollett Procedures for comparing hydrophone noise with minimum water noise , 1973 .

[25]  Robert Y. Ting,et al.  The evaluation of PVF2 for underwater shock‐wave sensor application , 1984 .

[26]  R. Tancrell,et al.  Properties of PVDF Polymer for Sonar , 1985, IEEE 1985 Ultrasonics Symposium.

[27]  A. Kolbeck Aging of piezoelectricity in poly(vinylidene fluoride) , 1982 .

[28]  D. Ricketts Multi-layered polymer hydrophone array , 1989 .

[29]  S. Ko,et al.  Flow noise reduction techniques for a planar array of hydrophones , 1991 .

[30]  Donald Ricketts,et al.  Transverse vibrations of composite piezoelectric polymer plates , 1985 .

[31]  J. Staudenraus,et al.  Fibre-optic probe hydrophone for ultrasonic and shock-wave measurements in water , 1993 .

[32]  C. Koch,et al.  Measurement of ultrasonic pressure by heterodyne interferometry with a fiber-tip sensor. , 1999, Applied optics.

[33]  Donald Ricketts Model for a piezoelectric polymer flexural plate hydrophone , 1981 .

[34]  J. Kilpatrick Piezoelectric polymer cylindrical hydrophone , 1978 .

[35]  I. M. Ward,et al.  Recent measurements on improved thick film piezoelectric pvdf polymer materials for hydrophone applications , 1983 .

[36]  Paul C. Beard,et al.  Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer , 1997 .

[37]  Richard B. Gilchrist,et al.  Experimental Hydrophone‐Size Correction Factor for Boundary‐Layer Pressure Fluctuations , 1965 .

[38]  Toshikazu Yoshimi,et al.  Electroacoustic Transducers with Piezoelectric High Polymer Films , 1975 .

[39]  T. T. Wang Aging behavior of piezoelectric poly(vinylidene fluoride) films irradiated by γ rays , 1981 .

[40]  Paul L. Carson,et al.  Simplified technique for the calibration and use of a miniature hydrophone in intensity measurements of pulsed ultrasound fields , 1981 .

[41]  Y. Bar-Cohen,et al.  Polymer Piezoelectric Transducers for Ultrasonic NDE , 1996 .