Motion planning for a three-stage multilumen transoral lung access system

Lung cancer is the leading cause of cancer-related death, and early-stage diagnosis is critical to survival. Biopsy is typically required for a definitive diagnosis, but current low-risk clinical options for lung biopsy cannot access all biopsy sites. We introduce a motion planner for a multilumen transoral lung access system, a new system that has the potential to perform safe biopsies anywhere in the lung, which could enable more effective early-stage diagnosis of lung cancer. The system consists of three stages in which a bronchoscope is deployed transorally to the lung, a concentric tube robot pierces through the bronchial tubes into the lung parenchyma, and a steerable needle deploys through a properly oriented concentric tube and steers through the lung parenchyma to the target site while avoiding anatomical obstacles such as significant blood vessels. A sampling-based motion planner computes actions for each stage of the system and considers the coupling of the stages in an efficient manner. We demonstrate the motion planner's fast performance and ability to compute plans with high clearance from obstacles in simulated anatomical scenarios.

[1]  Robert J. Webster,et al.  A multi-arm hand-held robotic system for transurethral laser Prostate surgery , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[2]  Luis Ibáñez,et al.  The ITK Software Guide , 2005 .

[3]  Dinesh Manocha,et al.  FCL: A general purpose library for collision and proximity queries , 2012, 2012 IEEE International Conference on Robotics and Automation.

[4]  Robert J. Webster,et al.  Tendons, concentric tubes, and a bevel tip: Three steerable robots in one transoral lung access system , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[5]  Steven Woloshin,et al.  Population-Based Risk for Complications After Transthoracic Needle Lung Biopsy of a Pulmonary Nodule: An Analysis of Discharge Records , 2011, Annals of Internal Medicine.

[6]  Robert J. Webster,et al.  Mechanics of Precurved-Tube Continuum Robots , 2009, IEEE Transactions on Robotics.

[7]  Jin Seob Kim,et al.  Diffusion-Based Motion Planning for a Nonholonomic Flexible Needle Model , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[8]  Jin Seob Kim,et al.  Nonholonomic Modeling of Needle Steering , 2006, Int. J. Robotics Res..

[9]  Tomer Anor,et al.  Robotic neuro-emdoscope with concentric tube augmentation , 2012, 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[10]  Philippe Poignet,et al.  Robot-assisted automatic insertion of steerable needles with closed-loop imaging feedback and intraoperative trajectory replanning , 2013 .

[11]  Cancer Facts & Figures 2021 , 2010 .

[12]  Steven M. LaValle,et al.  Rapidly-Exploring Random Trees: Progress and Prospects , 2000 .

[13]  Robert J. Webster,et al.  A motion planning approach to automatic obstacle avoidance during concentric tube robot teleoperation , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[14]  N R Dunnick,et al.  Percutaneous transthoracic needle aspiration: a review. , 1989, AJR. American journal of roentgenology.

[15]  D. Minhas,et al.  Modeling of Needle Steering via Duty-Cycled Spinning , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  Ron Alterovitz,et al.  High-Frequency Replanning Under Uncertainty Using Parallel Sampling-Based Motion Planning , 2015, IEEE Transactions on Robotics.

[17]  Robert J. Webster,et al.  Needle Steering in 3-D Via Rapid Replanning , 2014, IEEE Transactions on Robotics.

[18]  Geoffrey McLennan,et al.  Three-dimensional path planning for virtual bronchoscopy , 2004, IEEE Transactions on Medical Imaging.

[19]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[20]  Allison M. Okamura,et al.  Feedback control for steering needles through 3D deformable tissue using helical paths , 2009, Robotics: Science and Systems.

[21]  Steven M. LaValle,et al.  Planning algorithms , 2006 .

[22]  Michael M. Curtiss,et al.  RRTs for nonlinear, discrete, and hybrid planning and control , 2003, 42nd IEEE International Conference on Decision and Control (IEEE Cat. No.03CH37475).

[23]  Antoni Rosell,et al.  Motion planning for the Virtual Bronchoscopy , 2012, 2012 IEEE International Conference on Robotics and Automation.

[24]  Michael K Gould,et al.  Minimally invasive techniques for the diagnosis of peripheral pulmonary nodules , 2008, Current opinion in pulmonary medicine.

[25]  Gregory S. Chirikjian,et al.  Robotic Needle Steering: Design, Modeling, Planning, and Image Guidance , 2011 .

[26]  Rajnikant V. Patel,et al.  Position control of concentric-tube continuum robots using a modified Jacobian-based approach , 2013, 2013 IEEE International Conference on Robotics and Automation.

[27]  Kyle B. Reed,et al.  Robot-Assisted Needle Steering , 2011, IEEE Robotics & Automation Magazine.

[28]  Daniel Caleb Rucker,et al.  The mechanics of continuum robots: Model-based sensing and control , 2011 .

[29]  Hugh F. Durrant-Whyte,et al.  Using Lie Group Symmetries for Fast Corrective Motion Planning , 2010, WAFR.

[30]  Gregory S. Chirikjian,et al.  The Path-of-probability Algorithm for Steering and Feedback Control of Flexible Needles , 2010, Int. J. Robotics Res..

[31]  D. Caleb Rucker,et al.  Sliding Mode Control of Steerable Needles , 2013, IEEE Transactions on Robotics.

[32]  Robert J. Webster,et al.  A Flexure-Based Steerable Needle: High Curvature With Reduced Tissue Damage , 2013, IEEE Transactions on Biomedical Engineering.

[33]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.