Assessment of renal function using magnetic resonance quantitative histogram analysis based on spatial labeling with multiple inversion pulses

Background The incidence of chronic kidney disease (CKD) is high, and is easy to develop into end-stage renal disease (ESRD), which requires kidney dialysis or kidney transplantation. Therefore, we want to explore the clinical value of magnetic resonance quantitative histogram analysis based on spatial labeling with multiple inversion pulses (SLEEK) in assessing renal function in the early stage. Methods One hundred and twenty-nine patients underwent abdominal MRI examination, including a coronal SLEEK sequence. The patients were divided into the control group [CG, 47 cases, estimated glomerular filtration rate (eGFR) >90], the mild renal function impairment (mRI) group (48 cases, eGFR =60–90), and the moderate to severe renal function impairment (m-sRI) group (34 cases, eGFR <60). Two experienced radiologists delineated cortex and medulla regions of interest (ROIs) on SLEEK images to obtain cortex and medulla quantitative histogram parameters [Mean, Median, Percentiles (5th, 10th, 25th, 75th, and 90th), Skewness, Kurtosis, and Entropy] using FireVoxel. These histogram parameters were compared by proper statistical methods such as one-way analysis of variance, the χ2 test, and receiver operating characteristic (ROC) curve analysis. Results Four histogram parameters (Inhomogeneitycortex, Skewnesscortex, Kurtosismedulla, and Entropymedulla) differed significantly between the CG and the mRI group. One medulla (Entropymedulla) and nine cortex (Meancortex, Mediancortex, Kurtosiscortex, Entropycortex, and 5th, 10th, 25th, 75th, and 90th Percentilecortex) histogram parameters were significantly different between the m-RI and m-sRI groups. The most relevant parameter to eGFR was Inhomogenitycortex (r=−0.450, P<0.001). Inhomogeneitycortex had the largest area under the curve (AUC) for differentiating the mRI group from the CG (AUC =0.718; 95% CI: 0.616–0.806), while 25th Percentilecortex generated the largest AUC (AUC =0.786; 95% CI: 0.681–0.869) for differentiating the mRI and m-sRI groups. Conclusions Quantitative histogram parameters based on a SLEEK sequence can be used to supplement renal dysfunction assessment. Cortex histogram parameters are more valuable for evaluating renal function than medulla histogram parameters.

[1]  I. Kamel,et al.  One-stop assessment of renal function and renal artery in hypertensive patients with suspected renal dysfunction: non-enhanced MRI using spatial labeling with multiple inversion pulses , 2020, European Radiology.

[2]  Hai-Feng Liu,et al.  Whole‐Liver Apparent Diffusion Coefficient Histogram Analysis for the Diagnosis and Staging of Liver Fibrosis , 2019, Journal of magnetic resonance imaging : JMRI.

[3]  Long Jiang Zhang,et al.  Combination of Functional Magnetic Resonance Imaging and Histopathologic Analysis to Evaluate Interstitial Fibrosis in Kidney Allografts. , 2019, Clinical journal of the American Society of Nephrology : CJASN.

[4]  Xuelei Ma,et al.  Glioblastoma and Anaplastic Astrocytoma: Differentiation Using MRI Texture Analysis , 2019, Front. Oncol..

[5]  Z. Xing,et al.  Evaluating Renal Fibrosis with R2* Histogram Analysis of the Whole Cortex in a Unilateral Ureteral Obstruction Model. , 2019, Academic radiology.

[6]  I. Kamel,et al.  Assessment of tumor heterogeneity: Differentiation of periampullary neoplasms based on CT whole-lesion histogram analysis. , 2019, European journal of radiology.

[7]  Jiule Ding,et al.  Evaluation of renal dysfunction using texture analysis based on DWI, BOLD, and susceptibility-weighted imaging , 2019, European radiology.

[8]  M. Burnier,et al.  Acute hyperglycemia increases renal tissue oxygenation as measured by BOLD-MRI in healthy overweight volunteers. , 2019, Diabetes research and clinical practice.

[9]  R. Agarwal,et al.  Glomerular filtration rate: when to measure and in which patients? , 2018, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[10]  D. Hu,et al.  Differentiation of atypical pancreatic neuroendocrine tumors from pancreatic ductal adenocarcinomas: Using whole‐tumor CT texture analysis as quantitative biomarkers , 2018, Cancer medicine.

[11]  Ewald Moser,et al.  Magnetic resonance imaging T1- and T2-mapping to assess renal structure and function: a systematic review and statement paper , 2018, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[12]  I. Kamel,et al.  Subtype Differentiation of Small (≤ 4 cm) Solid Renal Mass Using Volumetric Histogram Analysis of DWI at 3-T MRI. , 2018, AJR. American journal of roentgenology.

[13]  Xiaoqiang Ding,et al.  Chronic kidney disease: Pathological and functional evaluation with intravoxel incoherent motion diffusion‐weighted imaging , 2018, Journal of magnetic resonance imaging : JMRI.

[14]  M. Stuber,et al.  Reduced cortical oxygenation predicts a progressive decline of renal function in patients with chronic kidney disease. , 2018, Kidney international.

[15]  S. Francis,et al.  Multiparametric Renal Magnetic Resonance Imaging: Validation, Interventions, and Alterations in Chronic Kidney Disease , 2017, Front. Physiol..

[16]  Perry J Pickhardt,et al.  CT Texture Analysis: Definitions, Applications, Biologic Correlates, and Challenges. , 2017, Radiographics : a review publication of the Radiological Society of North America, Inc.

[17]  A. Levey,et al.  Estimating Glomerular Filtration Rate Using Serum Creatinine. , 2017, Clinical chemistry.

[18]  M. Stuber,et al.  Reduction of cortical oxygenation in chronic kidney disease: evidence obtained with a new analysis method of blood oxygenation level-dependent magnetic resonance imaging , 2016, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[19]  J. Vallée,et al.  New Magnetic Resonance Imaging Index for Renal Fibrosis Assessment: A Comparison between Diffusion-Weighted Imaging and T1 Mapping with Histological Validation , 2016, Scientific Reports.

[20]  J. Soto,et al.  Utility of texture analysis for quantifying hepatic fibrosis on proton density MRI , 2015, Journal of magnetic resonance imaging : JMRI.

[21]  Dongmei Wu,et al.  Evaluation of Renal Oxygenation Level Changes after Water Loading Using Susceptibility-Weighted Imaging and T2* Mapping , 2015, Korean journal of radiology.

[22]  T. Tamada,et al.  Measurement of renal cortical thickness using noncontrast‐enhanced steady‐state free precession MRI with spatially selective inversion recovery pulse: Association with renal function , 2015, Journal of magnetic resonance imaging : JMRI.

[23]  Jeong Yeon Cho,et al.  Histogram analysis of apparent diffusion coefficient map of diffusion-weighted MRI in endometrial cancer: a preliminary correlation study with histological grade , 2014, Acta radiologica.

[24]  D. Hu,et al.  Depiction of transplant renal vascular anatomy and complications: unenhanced MR angiography by using spatial labeling with multiple inversion pulses. , 2014, Radiology.

[25]  Katsuyoshi Ito,et al.  Corticomedullary differentiation of the kidney: Evaluation with noncontrast‐enhanced steady‐state free precession (SSFP) MRI with time‐spatial labeling inversion pulse (time‐SLIP) , 2013, Journal of magnetic resonance imaging : JMRI.

[26]  L. Xia,et al.  Evaluation of renal artery in hypertensive patients by unenhanced MR angiography using spatial labeling with multiple inversion pulses sequence and by CT angiography. , 2012, AJR. American journal of roentgenology.

[27]  Josef Coresh,et al.  Chronic kidney disease , 2012, The Lancet.

[28]  Takeshi Johkoh,et al.  Evaluation of the mean and entropy of apparent diffusion coefficient values in chronic hepatitis C: correlation with pathologic fibrosis stage and inflammatory activity grade. , 2011, Radiology.

[29]  H. Rusinek,et al.  What causes diminished corticomedullary differentiation in renal insufficiency? , 2007, Journal of magnetic resonance imaging : JMRI.

[30]  A. Levey,et al.  A More Accurate Method To Estimate Glomerular Filtration Rate from Serum Creatinine: A New Prediction Equation , 1999, Annals of Internal Medicine.

[31]  J. Lv,et al.  Prevalence and Disease Burden of Chronic Kidney Disease. , 2019, Advances in experimental medicine and biology.

[32]  J. Cha,et al.  Feasibility of using computed tomography texture analysis parameters as imaging biomarkers for predicting risk grade of gastrointestinal stromal tumors: comparison with visual inspection , 2019, Abdominal Radiology.