Infrared Intensities of Liquids X: Accuracy of Current Methods of Obtaining Optical Constants from Multiple Attenuated Total Reflection Measurements Using the CIRCLE Cell

The literature description of the Bertie-Eysel method for obtaining the optical constants (i.e., the real and imaginary refractive indices) of liquids from multiple attenuated total reflection measurements using the CIRCLE cell is brought up to date in this paper. The accuracy of the computation methods is explored by analyzing pATR spectra which are themselves calculated from known k(ν˜) spectra that contain single Lorentzian bands, and the corresponding known n(ν˜) spectra, and also from simulated, known, n(ν˜) and k(ν˜) spectra of pure liquid methanol and glacial acetic acid. The optical constants are recovered from the pATR spectra and compared with the known originals. It is shown that k(ν˜) spectra that contain k(ν˜) values up to 0.8, 0.7, and 0.6 can be obtained accurately when the real refractive indices are near 1.3, 1.4, and 1.5, respectively. The method is, thus, reliable for spectra that can be accurately measured from the multiple reflections in the CIRCLE cell. It is likely to be troublesome for higher values of the real and the imaginary refractive indices. However, these are best measured by single-reflection methods, and more direct ways of computing the optical constants are available for such methods.

[1]  M. Urban,et al.  Evaluation and Analysis of Attenuated Total Reflectance FT-IR Spectra Using Kramers-Kronig Transforms , 1992 .

[2]  John E. Bertie,et al.  Infrared intensities of liquids. IX. The Kramers–Kronig transform, and its approximation by the finite Hilbert transform via fast Fourier transforms , 1992 .

[3]  John E. Bertie,et al.  Infrared intensities of liquids. VIII: Accurate baseline correction of transmission spectra of liquids for computation of absolute intensities, and the 1036 cm-1 band of benzene as a potential intensity standard , 1991 .

[4]  M. K. Ahmed,et al.  Infrared intensities of liquids. 5. Optical and dielectric constants, integrated intensities, and dipole moment derivatives of water and water-d2 at 22.degree.C , 1989 .

[5]  Koji Ohta,et al.  Comparison among Several Numerical Integration Methods for Kramers-Kronig Transformation , 1988 .

[6]  R. Jones,et al.  Infrared Intensities of Liquids III: The Photometric Accuracy of FT-IR Transmission Spectra of C5H10, CH3NO2, CH2Cl2, C6H6, C6H5·CH3, and C6H5Cl in the Liquid State at 25°C in 11- to 500-μm Cells , 1986 .

[7]  J. Bertie,et al.  Infrared Intensities of Liquids I: Determination of Infrared Optical and Dielectric Constants by FT-IR Using the CIRCLE ATR Cell , 1985 .

[8]  R. Jones,et al.  Absolute Absorption Intensity and Dispersion Measurements on Some Organic Liquids in the Infrared , 1980 .

[9]  M. Dignam,et al.  Determination of the spectra of the optical constants of bulk phases via Fourier transform ATR , 1988 .