Auto-correlation function of PD pulses under electrical treeing degradation

Pulse correlation in PD signals was analyzed with auto-correlation function of PD pulses occurring in tree channels at 50 Hz ac voltage application as well as PD pulses occurring in several simple model electrodes. It was clarified that the auto-correlation function of PD pulse trains was strongly affected by void shape including tree length. It was found that even simple model electrodes, which showed very similar /spl phi/-q distribution patterns to those of tree channels, had different auto-correlation functions from those of PD pulse trains of tree channels. The results suggest that the auto-correlation function may give additional information about the PD mechanism to that given by the /spl phi/-q distribution patterns. >

[1]  D. W. Gross,et al.  Phase resolving partial discharge pattern acquisition and frequency spectrum analysis , 1994, Proceedings of 1994 4th International Conference on Properties and Applications of Dielectric Materials (ICPADM).

[2]  D. Auckland,et al.  The electric strength of a narrow column of air bounded by a dielectric wall , 1974 .

[3]  E. Gulski,et al.  Neural networks as a tool for recognition of partial discharges , 1993 .

[4]  E. Gulski,et al.  Computer-aided measurement of partial discharges in HV equipment , 1993 .

[5]  R. J. Van Brunt,et al.  Importance of unraveling memory propagation effects in interpreting data on partial discharge statistics , 1993 .

[6]  C. Mayoux,et al.  Analysis of the Propagation of Electrical Treeing Using Optical and Electrical Methods , 1980, IEEE Transactions on Electrical Insulation.

[7]  Tatsuki Okamoto,et al.  Prediction of Treeing Breakdown from Pulse Height of Partial Discharge on Voltage-Phase Angle , 1985 .

[8]  C. Mayoux,et al.  Corona frequency analysis in artificial cavities in epoxy resins , 1973 .

[9]  N. Hozumi,et al.  Discrimination of partial discharge patterns using a neural network , 1991 .

[10]  Masayuki Hikita,et al.  Measurements of partial discharges by computer and analysis of partial discharge distribution by the Monte Carlo method , 1990 .

[11]  J. Fuhr,et al.  PD-fingerprints of some high voltage apparatus , 1990, IEEE International Symposium on Electrical Insulation.

[12]  T. Okamoto,et al.  Novel Partial Discharge Measurement Computer-Aided Measuremnet Systems , 1986, IEEE Transactions on Electrical Insulation.

[13]  A. Borishade,et al.  The Development of Electrical Discharges in Simulated "Tree" Channels , 1977, IEEE Transactions on Electrical Insulation.

[14]  M. Hoof,et al.  Pulse-sequence analysis: a new method for investigating the physics of PD-induced ageing , 1995 .

[15]  Tatsuki Okamoto Comprehensive partial discharge characteristics sensitive to electrode configuration , 1987, Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987.