Protection devices against DC fault in a back-to-back converter applied to distribution grids

This paper considers the possibility to connect two medium voltage primary distribution grids through a DC connection realized by two AD/DC converters in back-to-back configuration. In particular, after a description of the whole system, the effects of a bolted or non-bolted DC fault are analyzed. Then, an active current limiter is proposed to limit the fault currents and keep the controllability of the system. Such a system is then modeled and studied through many simulations that confirm the effectiveness of the proposed current limiter.

[1]  Chi-Seng Lam,et al.  Adaptive DC-Link Voltage-Controlled Hybrid Active Power Filters for Reactive Power Compensation , 2012, IEEE Transactions on Power Electronics.

[2]  Kjell Eriksson Operational experience of HVDC light , 2001 .

[3]  G. Asplund Application of HVDC Light to power system enhancement , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[4]  S.O. Faried,et al.  Power system stability enhancement using a Voltage Source Converter HVDC back-to-back link , 2006, 2006 Eleventh International Middle East Power Systems Conference.

[5]  Byung Hoon Chang,et al.  A study on the effects of BTB HVDC for fault current reduction applied metropolitan area in KEPCO Grid , 2011, 8th International Conference on Power Electronics - ECCE Asia.

[6]  U Ghisla,et al.  Fault protection and ride-through scheme for MVDC power distribution systems utilizing a supervisory controller , 2011, 2011 IEEE Electric Ship Technologies Symposium.

[7]  Y. Jiang-Hafner,et al.  On the short circuit current contribution of HVDC Light , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[8]  Fook Hoong Choo,et al.  Harmonizing AC and DC: A Hybrid AC/DC Future Grid Solution , 2013, IEEE Power and Energy Magazine.

[9]  Justin-Jin Zhang,et al.  Investigation of several new technologies for mega city power grid issues , 2006, 2006 International Conference on Power System Technology.

[10]  R. Chiumeo,et al.  Application of back-to-back converters in closed-loop and meshed MV distribution grid , 2014, 2014 AEIT Annual Conference - From Research to Industry: The Need for a More Effective Technology Transfer (AEIT).

[11]  Yao Zhang,et al.  Investigation on applying HVDC Light to China Southern Power Grid , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[12]  D. Dickinson,et al.  The Rapid City DC Tie , 2006, 2006 IEEE PES Power Systems Conference and Exposition.

[13]  M Boyra,et al.  Size comparison of MVDC and D-UPFC for MV distribution network interconnection , 2010, SPEEDAM 2010.

[14]  Niclas Ottosson,et al.  Modular back-to-back HVDC, with Capacitor Commutated Converters (CCC) , 2001 .

[15]  Seung-Ki Sul,et al.  DC-Link Voltage Stabilization for Reduced DC-Link Capacitor Inverter , 2014, IEEE Transactions on Industry Applications.

[16]  Jian Xiong,et al.  A novel topology and control strategy of DC fault current limiter , 2009, INTELEC 2009 - 31st International Telecommunications Energy Conference.

[17]  R. Hebner,et al.  Analysis of fault events in MVDC architecture , 2009, 2009 IEEE Electric Ship Technologies Symposium.