Real‐time interactive MRI‐guided cardiac surgery: Aortic valve replacement using a direct apical approach

Minimally invasive cardiac surgery requires arresting and emptying of the heart, which compromises visualization of the surgical field. In this feasibility study a novel surgical procedure is demonstrated in which real‐time MRI is used to guide the placement of a prosthetic aortic valve in the beating heart via direct apical access in eight porcine hearts. A clinical stentless bioprosthetic valve affixed to a platinum stent was compressed onto a balloon‐tipped catheter. This was fed through a 15–18‐mm delivery port inserted into the left ventricular (LV) apex via a minimally invasive subxyphoid incision. Using interactive real‐time MRI, the surgeon implanted the prosthetic valve in the correct location at the aortic annulus within 90 s. In four of the animals immediately after implantation, ventricular function, blood flow through the valve, and myocardial perfusion were evaluated with MRI. MRI‐guided beating‐heart surgery may provide patients with a less morbid and more durable solution to structural heart disease. Magn Reson Med, 2006. Published 2006 Wiley‐Liss, Inc.

[1]  A. Cribier,et al.  Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience. , 2006, Journal of the American College of Cardiology.

[2]  Cengizhan Ozturk,et al.  Real-Time Magnetic Resonance Imaging–Guided Endovascular Recanalization of Chronic Total Arterial Occlusion in a Swine Model , 2006, Circulation.

[3]  Robert J. Lederman,et al.  Cardiovascular Interventional MRI , 2005 .

[4]  R. Lederman Cardiovascular Interventional Magnetic Resonance Imaging , 2005, Circulation.

[5]  R. Blanco,et al.  Interventional and intraoperative MRI at low field scanner--a review. , 2005, European journal of radiology.

[6]  Maythem Saeed,et al.  Endovascular interventional MRI , 2005, Journal of magnetic resonance imaging : JMRI.

[7]  P. Bonhoeffer,et al.  Steps toward the percutaneous replacement of atrioventricular valves an experimental study. , 2005, Journal of the American College of Cardiology.

[8]  Richard B. Thompson,et al.  Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine. , 2005, Journal of the American College of Cardiology.

[9]  T. Vassiliades,et al.  The clinical development of percutaneous heart valve technology: a position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI). , 2005, The Annals of thoracic surgery.

[10]  E. Nagel,et al.  Magnetic resonance imaging-guided transcatheter implantation of a prosthetic valve in aortic valve position: Feasibility study in swine. , 2004, Journal of the American College of Cardiology.

[11]  Reza Ardehali,et al.  Percutaneous valve replacement: current state and future prospects. , 2004, The Annals of thoracic surgery.

[12]  Thomas Kahn,et al.  Interventional and intraoperative MR: review and update of techniques and clinical experience , 2004, European Radiology.

[13]  T. Mihaljevic,et al.  One Thousand Minimally Invasive Valve Operations: Early and Late Results , 2004, Annals of surgery.

[14]  P. Bonhoeffer,et al.  Percutaneous Aortic Valve Replacement in Animals , 2004 .

[15]  E R McVeigh,et al.  Extended coverage first‐pass perfusion imaging using slice‐interleaved TSENSE , 2004, Magnetic resonance in medicine.

[16]  Elliot R. McVeigh,et al.  Magnetic Resonance Fluoroscopy Allows Targeted Delivery of Mesenchymal Stem Cells to Infarct Borders in Swine , 2003, Circulation.

[17]  Peter Kellman,et al.  Real‐time accelerated interactive MRI with adaptive TSENSE and UNFOLD , 2003, Magnetic resonance in medicine.

[18]  Jonathan M Sorger,et al.  Catheter-Based Endomyocardial Injection With Real-Time Magnetic Resonance Imaging , 2002, Circulation.

[19]  D. Doty,et al.  Cardiac Valve Operations Using a Partial Sternotomy (Lower Half) Technique , 2000, Journal of cardiac surgery.

[20]  D. Cosgrove,et al.  Minimally invasive valve operations. , 1998, The Annals of thoracic surgery.

[21]  R. Herfkens,et al.  Phase contrast cine magnetic resonance imaging. , 1991, Magnetic resonance quarterly.

[22]  P. Bonhoeffer,et al.  Images in cardiovascular medicine. Percutaneous aortic valve replacement in animals. , 2004, Circulation.