UHV AC corona loss measurement and analysis under rain

Transmission line corona loss research is one of the critical technologies of 1000kV UHV transmission and transformation engineering. Transmission line corona loss relates with many factors of climate, and rainfall rate effects corona loss distinctly very much. By means of UHV AC single circuit test line corona loss monitoring and UHV corona cage conductor corona loss measurement, this paper researched the effect of rainfall rates to UHV AC single circuit transmission line's corona loss. This paper applied corona loss monitoring system to monitor corona loss of UHV single circuit test line, and obtained corona loss monitoring data in light rain, moderate rain, and heavy rain conditions. Analyze corona loss test results. Corona loss value in light rain, moderate rain, and heavy rain conditions are obtained. The results show that, rain has an obvious influence on corona loss of the line, at the beginning of raining, corona loss increases quickly, after rain, corona loss decreases with drying of the conductor. Decay time is related with surface field strength, wind speed, air humidity, temperature and other factors. When rainfall rate is low, corona loss increases fast with the increase of the rainfall rate. With the increase of the rainfall rate, corona loss grows slowly. When rainfall rate increases to some level, corona loss stop growing.

[1]  L. E. Zaffanella,et al.  Radio Noise, Audible Noise, and Corona Loss of EHV and UHV Transmission Lines Under Rain: Predetermination Based on Cage Tests , 1970 .

[2]  Chen Xiaoyan Corona Measurement Technology and Result on Test Lines , 2006 .

[3]  P. Sarma Maruvada,et al.  Corona Performance of High Voltage Transmission Lines , 2000 .

[4]  Mao Su-chun Development of a Leakage Current Monitoring System for Pollution Test Lab , 2007 .

[5]  Jacques J. Clade,et al.  Calculation of Corona Losses Beyond the Critical Gradient in Alternating Voltage , 1969 .

[6]  Zhang Xiaowu Study on EM Environment of UHV Test Line Segment , 2008 .

[7]  Wu Zhi-rong Construction of UHV AC Test Base of SGCC , 2007 .

[8]  Huo Feng Research on Section and Split Way of Conductors for UHVAC Transmission Project , 2008 .

[9]  D.V.Razevig High voltage engineering , 2006, 2006 Eleventh International Middle East Power Systems Conference.

[10]  Yu Juying Analysis of Research on UHV AC Transmission in China , 2005 .

[11]  Chen Weijiang Design and Realization of AC UHV Corona Loss Monitoring System , 2008 .

[12]  Huang Dao-chun Study on Electromagnetic Environment of UHV AC Transmission Lines , 2007 .

[13]  Hu Yi Discussion on Test Line and Relevent Technique of UHV Transmission , 2004 .

[14]  Gu Shan-qiang Discussion on Key Problems in the Design of 1000 kV Ultra-high Voltage AC Corona Cage , 2007 .

[15]  Hu Wei Corona Characteristics of Conductors for 1000 kV AC Transmission Lines , 2007 .

[16]  Claude H. Gary,et al.  Predetermination of Corona Losses Under Rain: Experimental Interpreting and Checking of a Method to Calculate Corona Losses , 1970 .

[17]  Y Shu,et al.  Research of Key Technologies for UHV Transmission , 2007 .

[18]  Pu Jun-song Simulation Analysis of Three Software Dielectric Loss Measuring Algorithm , 2005 .

[19]  Yu Yu-hong DISCUSSION ON SEVERAL IMPORTANT PROBLEMS OF DEVELOPING UHV AC TRANSMISSON IN CHINA , 2005 .

[20]  Jacques J. Clade,et al.  Predetermination of Corona Losses Under Rain: Influence of Rain Intensity and Utilization of a Universal Chart , 1970 .