Linearity evaluation in absorbance detection: The use of light‐emitting diodes for on‐capillary detection in capillary electrophoresis

A model which takes into account both stray light and polychromatic light was used to predict and evaluate linearity in on‐capillary detection in capillary electrophoresis (CE). According to the model the stray light is the major factor which determines linearity under typical CE operating conditions. By calculating theoretical absorbance versus concentration plots, the influence of different levels of stray light and polychromatic light on linearity is demonstrated. Experimentally, six light‐emitting diodes (LEDs) in the range from 563 to 654 nm were examined as light sources for on‐capillary detection in CE. Fitting theoretical curves to measured linearity plots enabled determination of the values of both effective path lenght and stray light for a particular detection system. The detector linearity for the four LEDs was compared to mercury and tungsten lamps used with interference filters. For potassium permanganate as the test compound, the linear range for a 563 nm LED was two times greater than that for a mercury lamp operated at 546 nm. The relatively poor linearity of the mercury lamp detector is explained by its high level of stray light. The noise of the LED563‐based detector was the same as for the mercury lamp, whereas the other LEDs of higher light intensity gave approximately half the noise of the mercury lamp. The lowest noise level of 3 × 10−5 AU was obtained for the LED at 554 nm (determined at a detector time constant of 0.1 s).

[1]  R. Scott,et al.  A vapour dilution system for detector calibration. , 1963, Journal of chromatography.

[2]  P. Hauser,et al.  A photometric detector based on a blue light-emitting diode. , 1993, Talanta.

[3]  S. Fanali,et al.  Resolution of optical isomers by capillary zone electrophoresis: Study of enantiomeric and diastereoisomeric Co(III) complexes with ethylenediamine and amino acid ligands , 1989 .

[4]  Philippe Nussbaum,et al.  The pigtailing approach to optical detection in capillary electrophoresis , 1994 .

[5]  M. Macka,et al.  Determination of Acyclovir in Blood Serum and Plasma by Micellar Liquid Chromatography with Fluorimetric Detection , 1993 .

[6]  E. Bergström,et al.  Diode laser-based indirect absorbance detector for capillary electrophoresis , 1993 .

[7]  Ernst Gassmann,et al.  On-column capillary flow cell utilizing optical waveguides for chromatographic applications , 1989 .

[8]  E. Loree,et al.  Light emitting diode based flow-through optical absorption detectors. , 1993, Talanta.

[9]  P. Hauser,et al.  A multi-wavelength photometer based on light-emitting diodes. , 1995, Talanta.

[10]  E. Yeung,et al.  Simple double-beam absorption detection systems for capillary electrophoresis based on diode lasers and light-emitting diodes , 1995 .

[11]  R. Cassidy,et al.  Is your calibration curve linear , 1992 .

[12]  M. Sepaniak,et al.  Instrumental developments in micellar electrokinetic capillary chromatography , 1989 .

[13]  J. Jorgenson,et al.  On-column UV absorption detector for open tubular capillary zone electrophoresis , 1984 .

[14]  Robert A. Meyers Encyclopedia of lasers and optical technology , 1991 .

[15]  Gerard J. M. Bruin,et al.  Optimization and evaluation of the performance of arrangements for UV detection in high-resolution separations using fused-silica capillaries , 1991 .

[16]  Tiansong. Wang,et al.  Adjustable aperture-width detector cell for on-column detection in capillary zone electrophoresis , 1989 .