Technology behind commercial devices for blood glucose monitoring in diabetes management: a review.

[1]  E. W. Washburn The Dynamics of Capillary Flow , 1921 .

[2]  D. Keilin,et al.  Specificity of glucose oxidase (notatin). , 1952, The Biochemical journal.

[3]  A. H. Free,et al.  Specificity of glucose oxidase. , 1960, Archives of biochemistry and biophysics.

[4]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[5]  G. Hicks,et al.  The Enzyme Electrode , 1967, Nature.

[6]  G. Pfleiderer,et al.  D-glucose dehydrogenase from Bacillus megaterium M 1286: purification, properties and structure. , 1975, Hoppe-Seyler's Zeitschrift fur physiologische Chemie.

[7]  J. Duine,et al.  Glucose dehydrogenase from Acinetobacter calcoaceticus , 1979, FEBS letters.

[8]  A. Turner,et al.  Ferrocene-mediated enzyme electrode for amperometric determination of glucose. , 1984, Analytical chemistry.

[9]  R. Marcus,et al.  Electron transfers in chemistry and biology , 1985 .

[10]  J. Frank,et al.  Purification and characterization of quinoprotein glucose dehydrogenase from Acinetobacter calcoaceticus L.M.D. 79.41. , 1986, The Biochemical journal.

[11]  Adam Heller,et al.  Direct electrical communication between chemically modified enzymes and metal electrodes. I. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme , 1987 .

[12]  H. Zimmerman,et al.  Confinement control in solid-state photochemistry , 1989 .

[13]  Adam Heller,et al.  Electrical communication between redox centers of glucose oxidase and electrodes via electrostatically and covalently bound redox polymers , 1989 .

[14]  Michael V. Pishko,et al.  Direkter Elektronenaustausch zwischen Graphitelektroden und einem adsorbierten Komplex aus Glucose‐Oxidase und einem Os‐haltigen Redoxpolymer , 1990 .

[15]  K. Kyvik,et al.  The ExacTech blood glucose testing system. , 1990, Diabetes research and clinical practice.

[16]  A Heller,et al.  Cross-linked redox gels containing glucose oxidase for amperometric biosensor applications. , 1990, Analytical chemistry.

[17]  Adam Heller,et al.  Redox polymer films containing enzymes. 2. Glucose oxidase containing enzyme electrodes , 1991 .

[18]  A Heller,et al.  Amperometric glucose microelectrodes prepared through immobilization of glucose oxidase in redox hydrogels. , 1991, Analytical chemistry.

[19]  Adam Heller,et al.  Redox polymer films containing enzymes. 1. A redox-conducting epoxy cement: synthesis, characterization, and electrocatalytic oxidation of hydroquinone , 1991 .

[20]  Adam Heller,et al.  Electrical Connection of Enzyme Redox Centers to Electrodes , 1992 .

[21]  Adam Heller,et al.  Electron Diffusion Coefficients in Hydrogels Formed of Cross-Linked Redox Polymers , 1993 .

[22]  Adam Heller,et al.  High current density "wired" quinoprotein glucose dehydrogenase electrode , 1993 .

[23]  J. A. Hubbell,et al.  Design, characterization, and one-point in vivo calibration of a subcutaneously implanted glucose electrode. , 1994, Analytical chemistry.

[24]  A Heller,et al.  "Wired" enzyme electrodes for amperometric determination of glucose or lactate in the presence of interfering substances. , 1994, Analytical chemistry.

[25]  A. Ivaska,et al.  Evaluation of amperometric glucose biosensors based on co-immobilisation of glucose oxidase with an osmium redox polymer in electrochemically generated polyphenol films , 1995 .

[26]  Adam Heller,et al.  “Wiring” of glucose oxidase within a hydrogel made with polyvinyl imidazole complexed with [(Os-4,4′-dimethoxy-2,2′-bipyridine)Cl]+/2+1 , 1995 .

[27]  Ibtisam E. Tothill,et al.  Catalytic Materials, Membranes, and Fabrication Technologies Suitable for the Construction of Amperometric Biosensors , 1995 .

[28]  A Heller,et al.  Design and optimization of a selective subcutaneously implantable glucose electrode based on "wired" glucose oxidase. , 1995, Analytical chemistry.

[29]  D Schomburg,et al.  The design of enzyme sensors based on the enzyme structure. , 1995, Biosensors & bioelectronics.

[30]  Adam Heller,et al.  EFFECT OF QUATERNIZATION ON ELECTRON DIFFUSION COEFFICIENTS FOR REDOX HYDROGELS BASED ON POLY(4-VINYLPYRIDINE) , 1995 .

[31]  V Marks,et al.  Blood glucose: its measurement and clinical importance. , 1996, Clinica chimica acta; international journal of clinical chemistry.

[32]  L J Cartier,et al.  Toxic levels of acetaminophen produce a major positive interference on Glucometer Elite and Accu-chek Advantage glucose meters. , 1998, Clinical chemistry.

[33]  C. Danilowicz,et al.  Osmium complexes bearing functional groups : building blocks for integrated chemical systems , 1998 .

[34]  J. Duine,et al.  On the mechanism and specificity of soluble, quinoprotein glucose dehydrogenase in the oxidation of aldose sugars. , 1998, Biochemistry.

[35]  A Heller,et al.  Implanted electrochemical glucose sensors for the management of diabetes. , 1999, Annual review of biomedical engineering.

[36]  K. H. Kalk,et al.  Structure and mechanism of soluble quinoprotein glucose dehydrogenase , 1999, The EMBO journal.

[37]  J. Skyler,et al.  FreeStyle: a small-volume electrochemical glucose sensor for home blood glucose testing. , 2000, Diabetes technology & therapeutics.

[38]  A. Ryabov,et al.  4-Ferrocenylphenol as an electron transfer mediator in PQQ-dependent alcohol and glucose dehydrogenase-catalyzed reactions , 2000 .

[39]  G J Kost,et al.  Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer. , 2000, American journal of clinical pathology.

[40]  P. Bartlett,et al.  Electrodeposition and properties of nanostructured platinum films studied by quartz crystal impedance measurements at 10 MHz , 2000 .

[41]  R. Lehmann,et al.  Clinical and technical evaluation of a new self-monitoring blood glucose meter: assessment of analytical and user error. , 2001, Diabetes research and clinical practice.

[42]  T. Mallouk,et al.  Combinatorial discovery of alloy electrocatalysts for amperometric glucose sensors. , 2001, Analytical chemistry.

[43]  K. Kano,et al.  Ca(2+) stabilizes the semiquinone radical of pyrroloquinoline quinone. , 2001, The Biochemical journal.

[44]  Qiang Gao,et al.  Flow injection analytical system for glucose with screen-printed enzyme biosensor incorporating Os-complex mediator , 2001 .

[45]  W. Schuhmann,et al.  A reagentless glucose biosensor based on glucose oxidase entrapped into osmium-complex modified polypyrrole films , 2001 .

[46]  K. Sode,et al.  THE APPLICATION OF CYTOCHROMES AS THE INTERFACE MOLECULE TO FACILITATE THE ELECTRON TRANSFER FOR PQQ GLUCOSE DEHYDROGENASE EMPLOYING MEDIATOR TYPE GLUCOSE SENSOR , 2002 .

[47]  Nigel J. Forrow,et al.  The influence of structure in the reaction of electrochemically generated ferrocenium derivatives with reduced glucose oxidase , 2002 .

[48]  Bogdan Solnica,et al.  Analytical performance of glucometers used for routine glucose self-monitoring of diabetic patients. , 2003, Clinica chimica acta; international journal of clinical chemistry.

[49]  Sejin Park,et al.  Nonenzymatic glucose detection using mesoporous platinum. , 2003, Analytical chemistry.

[50]  Ronald Brazg,et al.  A continuous glucose sensor based on wired enzyme technology -- results from a 3-day trial in patients with type 1 diabetes. , 2003, Diabetes technology & therapeutics.

[51]  Adam Heller,et al.  Long tethers binding redox centers to polymer backbones enhance electron transport in enzyme "Wiring" hydrogels. , 2003, Journal of the American Chemical Society.

[52]  A. Ryabov,et al.  Wiring of PQQ-dehydrogenases. , 2004, Biosensors & bioelectronics.

[53]  Fwu-Shan Sheu,et al.  Nonenzymatic glucose detection using multi-walled carbon nanotube electrodes , 2004 .

[54]  Adam Heller,et al.  Electro-oxidation of glucose at an increased current density at a reducing potential. , 2004, Chemical communications.

[55]  T. Chung,et al.  Ionic strength-controlled virtual area of mesoporous platinum electrode. , 2004, Journal of the American Chemical Society.

[56]  Biocompatible glucose sensor prepared by modifying protein and vinylferrocene monomer composite membrane. , 2004, Biosensors & bioelectronics.

[57]  Nigel J. Forrow,et al.  Transition metal half-sandwich complexes as redox mediators to glucose oxidase. , 2004, Biosensors & bioelectronics.

[58]  Eric Renard,et al.  Monitoring glycemic control: the importance of self-monitoring of blood glucose. , 2005, The American journal of medicine.

[59]  P. Joshi,et al.  Amperometric biosensors based on redox polymer-carbon nanotube-enzyme composites. , 2005, Analytical chemistry.

[60]  Adam Heller,et al.  On the parameters affecting the characteristics of the "wired" glucose oxidase anode , 2005 .

[61]  D. Peričin,et al.  Glucose oxidase from Aspergillus niger: the mechanism of action with molecular oxygen, quinones, and one-electron acceptors. , 2005, The international journal of biochemistry & cell biology.

[62]  R. Bergenstal,et al.  The role of self-monitoring of blood glucose in the care of people with diabetes: report of a global consensus conference. , 2005, The American journal of medicine.

[63]  David C Klonoff,et al.  A review of continuous glucose monitoring technology. , 2005, Diabetes technology & therapeutics.

[64]  A. Karter,et al.  Current evidence regarding the value of self-monitored blood glucose testing. , 2005, The American journal of medicine.

[65]  Hubert W Vesper,et al.  Variability among five over-the-counter blood glucose monitors. , 2006, Clinica chimica acta; international journal of clinical chemistry.

[66]  J. Kulys,et al.  Probing Aspergillus niger glucose oxidase with pentacyanoferrate(III) aza- and thia-complexes. , 2006, Journal of inorganic biochemistry.

[67]  S. Garg,et al.  Chapter 33 – Glucose Monitoring of the Present and Future , 2006 .

[68]  Adam Heller,et al.  Electron-conducting redox hydrogels: Design, characteristics and synthesis. , 2006, Current opinion in chemical biology.

[69]  Kenji Kano,et al.  Novel FAD-Dependent Glucose Dehydrogenase for a Dioxygen-Insensitive Glucose Biosensor , 2006, Bioscience, biotechnology, and biochemistry.

[70]  R. Hovorka Continuous glucose monitoring and closed‐loop systems , 2006, Diabetic medicine : a journal of the British Diabetic Association.

[71]  Barbara Ballarin,et al.  Enzyme electrodes based on sono-gel containing ferrocenyl compounds. , 2007, Biosensors & bioelectronics.

[72]  V. Fonseca Clinical Diabetes: Translating Research into Practice , 2007, Annals of Internal Medicine.

[73]  A. Maran,et al.  Non-invasive glucose monitoring: assessment of technologies and devices according to quantitative criteria. , 2007, Diabetes research and clinical practice.

[74]  Itamar Willner,et al.  Integrated nanoparticle-biomolecule systems for biosensing and bioelectronics. , 2007, Biosensors & bioelectronics.

[75]  J. Ho,et al.  Dual electrochemical determination of glucose and insulin using enzyme and ferrocene microcapsules. , 2007, Biosensors & bioelectronics.

[76]  Huaping Peng,et al.  Ferrocene-modified Fe3O4@SiO2 magnetic nanoparticles as building blocks for construction of reagentless enzyme-based biosensors , 2007 .

[77]  Huaiguo Xue,et al.  Electrochemical study of ferrocenemethanol-modified layered double hydroxides composite matrix: application to glucose amperometric biosensor. , 2007, Biosensors & bioelectronics.

[78]  L. Gorton,et al.  Development of a carbon nanotube paste electrode osmium polymer-mediated biosensor for determination of glucose in alcoholic beverages. , 2007, Biosensors & bioelectronics.

[79]  Thomas G Schleis,et al.  Interference of Maltose, Icodextrin, Galactose, or Xylose with Some Blood Glucose Monitoring Systems , 2007, Pharmacotherapy.

[80]  Carlos Eduardo Ferrante do Amaral,et al.  Current development in non-invasive glucose monitoring. , 2008, Medical engineering & physics.

[81]  Ling Xiang,et al.  In situ cationic ring-opening polymerization and quaternization reactions to confine ferricyanide onto carbon nanotubes: a general approach to development of integrative nanostructured electrochemical biosensors. , 2008, Analytical chemistry.

[82]  Nigel A. Surridge,et al.  The Technology Behind Glucose Meters: Test Strips , 2008 .

[83]  V. Flexer,et al.  Wired-enzyme core-shell Au nanoparticle biosensor. , 2008, Journal of the American Chemical Society.

[84]  D. Aslan,et al.  Technical and clinical evaluation of a glucose meter employing amperometric biosensor technology. , 2008, Diabetes research and clinical practice.

[85]  Joseph Wang Electrochemical glucose biosensors. , 2008, Chemical reviews.

[86]  R. Bergenstal Evaluating the Accuracy of Modern Glucose Meters , 2008 .

[87]  Jianding Qiu,et al.  Ferrocene-modified multiwalled carbon nanotubes as building block for construction of reagentless enzyme-based biosensors , 2008 .

[88]  Edgard Delvin,et al.  Continuous glucose monitoring: a review of biochemical perspectives and clinical use in type 1 diabetes. , 2009, Clinical biochemistry.

[89]  B. Ginsberg Factors Affecting Blood Glucose Monitoring: Sources of Errors in Measurement , 2009, Journal of diabetes science and technology.

[90]  R. Bergenstal,et al.  Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System. , 2009, Diabetes technology & therapeutics.

[91]  X. Xia,et al.  Electrochemically deposited nanocomposite film of CS-Fc/Au NPs/GOx for glucose biosensor application. , 2009, Biosensors & bioelectronics.

[92]  Huiqin Yao,et al.  pH-Sensitive "on-off" switching behavior of layer-by-layer films assembled by concanavalin A and dextran toward electroactive probes and its application in bioelectrocatalysis. , 2009, The journal of physical chemistry. B.

[93]  Heather A Clark,et al.  Nanosensors and nanomaterials for monitoring glucose in diabetes. , 2010, Trends in molecular medicine.

[94]  Sandeep Kumar Vashist,et al.  Interfacing carbon nanotubes with living mammalian cells and cytotoxicity issues. , 2010, Chemical research in toxicology.

[95]  Andrew St John,et al.  The value of self-monitoring of blood glucose: a review of recent evidence. , 2010, Journal of diabetes and its complications.

[96]  J. Shaw,et al.  Global estimates of the prevalence of diabetes for 2010 and 2030. , 2010, Diabetes research and clinical practice.

[97]  Michael Stumvoll,et al.  On what evidence-base do we recommend self-monitoring of blood glucose? , 2010, Diabetes research and clinical practice.

[98]  Adam Heller,et al.  Electrochemistry in diabetes management. , 2010, Accounts of chemical research.

[99]  S. K. Vashist,et al.  Advances in carbon nanotube based electrochemical sensors for bioanalytical applications. , 2011, Biotechnology advances.

[100]  E. C. Rama,et al.  Enzymatic Sensor Using Mediator‐Screen‐Printed Carbon Electrodes , 2011 .