Exploiting the instability of eccentric tube robots for distal force control in minimally invasive cardiac ablation

While the dilemma of motion tracking and force control in beating-heart surgery is previously addressed using active control architectures and rigid robotic actuators, this work leverages the highly controllable mechanical properties of concentric tube robots for intelligent, design-based force control in minimally invasive cardiac ablation. Briefly, cardiac ablation is the conventional procedure for treating arrhythmia patients, by which exposing the diseased cardiac tissue to Radio-Frequency (RF) energy restores the normal heart rhythm. Yet, the procedure suffers low success rate due to the inability of existing flexible catheters to maintain a consistent, optimal contact force between the tip electrode and the tissue, imposing the need for future repeat surgeries upon disease recurrence. The novelty of our work lies in the development of a statically-balanced compliant mechanism composed of (1) distal bi-stable concentric tubes and (2) a compliant, torsional spring mechanism that provides torque at tubes proximal extremity, resulting in an energy-free catheter with a zero-stiffness tip. This catheter is expected to maintain surgical efficacy and safety despite the chaotic displacement of the heart, by naturally keeping the tip force at an optimal level, not less and not more than the surgical requirement. The presented experimental results of the physical prototype, reflect the feasibility of the proposed design, as well as the robustness of the formulated catheter mathematical models which were uniquely deployed in the selection of the optimal design parameters.

[1]  Sungchul Kang,et al.  Anisotropic Patterning to Reduce Instability of Concentric-Tube Robots , 2015, IEEE Transactions on Robotics.

[2]  Peter Rausch,et al.  Incidence and anatomical locations of catheter instability during circumferential pulmonary vein isolation using contact force. , 2014, International heart journal.

[3]  Robert D. Howe,et al.  Design and control of motion compensation cardiac catheters , 2010, 2010 IEEE International Conference on Robotics and Automation.

[4]  M. Mack Minimally invasive cardiac surgery , 2006, Surgical Endoscopy And Other Interventional Techniques.

[5]  Sungchul Kang,et al.  Toward a solution to the snapping problem in a concentric-tube continuum robot: Grooved tubes with anisotropy , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[6]  N. Zemiti,et al.  Mechatronic Design of a New Robot for Force Control in Minimally Invasive Surgery , 2007, IEEE/ASME Transactions on Mechatronics.

[7]  Cesare Stefanini,et al.  Concentric Tube Robots for Minimally Invasive Surgery: Current Applications and Future Opportunities , 2020, IEEE Transactions on Medical Robotics and Bionics.

[8]  Guang-Zhong Yang,et al.  The role of technology in minimally invasive surgery: state of the art, recent developments and future directions , 2016, Postgraduate Medical Journal.

[9]  P Zickler,et al.  Cardiac mapping. , 1997, Biomedical instrumentation & technology.

[10]  Keye Wu,et al.  Effect of retrograde autologous priming based on miniaturized cardiopulmonary bypass in children undergoing open heart surgery , 2020, Medicine.

[11]  Robert J. Webster,et al.  A motion planning approach to automatic obstacle avoidance during concentric tube robot teleoperation , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[12]  Jan Petru,et al.  Electrical Reconnection After Pulmonary Vein Isolation Is Contingent on Contact Force During Initial Treatment: Results From the EFFICAS I Study , 2013, Circulation. Arrhythmia and electrophysiology.

[13]  Robert D. Howe,et al.  Robotic catheter cardiac ablation combining ultrasound guidance and force control , 2014, Int. J. Robotics Res..

[14]  L.D. Seneviratne,et al.  State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery , 2008, IEEE Sensors Journal.

[15]  Robert D. Howe,et al.  Robotic Motion Compensation for Beating Heart Intracardiac Surgery , 2009, Int. J. Robotics Res..

[16]  V. Falk Manual control and tracking--a human factor analysis relevant for beating heart surgery. , 2002, Annals of Thoracic Surgery.

[17]  John D. Ferguson,et al.  Wall-Motion Based Analysis of Global and Regional Left Atrial Mechanics , 2013, IEEE Transactions on Medical Imaging.

[18]  Rui Pedro Duarte Cortesão,et al.  Model predictive control architectures with force feedback for robotic-assisted beating heart surgery , 2014, 2014 IEEE International Conference on Robotics and Automation (ICRA).

[19]  Guimin Chen,et al.  Fully-compliant statically-balanced mechanisms without prestressing assembly: concepts and case studies , 2011 .

[20]  George A Mensah,et al.  Global burden of atrial fibrillation in developed and developing nations. , 2014, Global heart.

[21]  Yili Fu,et al.  Steerable catheters in minimally invasive vascular surgery , 2009, The international journal of medical robotics + computer assisted surgery : MRCAS.

[22]  Jan Petru,et al.  EFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillation , 2015, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[23]  Makoto Iwasaki,et al.  Modeling, observation, and control of hysteresis torsion in elastic robot joints , 2014 .

[24]  D. Caleb Rucker,et al.  Concentric Tube Robots: The State of the Art and Future Directions , 2013, ISRR.

[25]  Fumiya Iida,et al.  Soft Robotics: Challenges and Perspectives , 2011, FET.

[26]  P. E. Dupont,et al.  Concentric Tube Robots for Minimally Invasive Surgery , 2012 .

[27]  Farrokh Janabi-Sharifi,et al.  An Efficient Static Model for Steerablè Catheters , 2014, 2014 IEEE 27th Canadian Conference on Electrical and Computer Engineering (CCECE).

[28]  H. Lambert,et al.  Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and Thrombus , 2008, Circulation. Arrhythmia and electrophysiology.

[29]  Matthew Wright,et al.  Advances in Imaging for Atrial Fibrillation Ablation , 2011, Radiology research and practice.

[30]  P. Kapoor,et al.  Anesthetic Challenges in Minimally Invasive Cardiac Surgery , 2019, Journal of Cardiac Critical Care TSS.

[31]  Robert D. Howe,et al.  Force tracking with feed-forward motion estimation for beating heart surgery , 2010, IEEE Transactions on Robotics.

[32]  T. N. Harrison,et al.  Association of Burden of Atrial Fibrillation With Risk of Ischemic Stroke in Adults With Paroxysmal Atrial Fibrillation: The KP-RHYTHM Study , 2018, JAMA cardiology.

[33]  Pierre E. Dupont,et al.  Design and Control of Concentric-Tube Robots , 2010, IEEE Transactions on Robotics.

[34]  Philippe Poignet,et al.  Compensation for 3D physiological motion in robotic-assisted surgery using a predictive force controller. Experimental results , 2009, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[35]  D. Shah,et al.  Real-Time Contact Force Measurement: A Key Parameter for Controlling Lesion Creation With Radiofrequency Energy , 2015, Circulation. Arrhythmia and electrophysiology.

[36]  Makoto Iwasaki,et al.  Sensorless Torsion Control of Elastic-Joint Robots With Hysteresis and Friction , 2016, IEEE Transactions on Industrial Electronics.

[37]  D. Lin,et al.  Localization of atrial fibrillation triggers in patients undergoing pulmonary vein isolation: importance of the carina region. , 2008, Journal of the American College of Cardiology.

[38]  P. Sanders,et al.  Complications of Catheter Ablation of Atrial Fibrillation: A Systematic Review , 2013, Circulation. Arrhythmia and electrophysiology.

[39]  M. O'Neill,et al.  Catheter Contact Force : A Review of Emerging Techniques and Technologies in AF Ablation , 2014 .

[40]  Robert J. Webster,et al.  Rapid, Reliable Shape Setting of Superelastic Nitinol for Prototyping Robots , 2016, IEEE Robotics and Automation Letters.

[41]  Kai Xu,et al.  Intrinsic Wrench Estimation and Its Performance Index for Multisegment Continuum Robots , 2010, IEEE Transactions on Robotics.

[42]  Nadir Saoudi,et al.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. , 2012, Heart rhythm.

[43]  A. Diez-Ibarbia,et al.  Efficiency analysis of spur gears with a shifting profile , 2016 .

[44]  Pierre E. Dupont,et al.  Design optimization of concentric tube robots based on task and anatomical constraints , 2011, 2011 IEEE International Conference on Robotics and Automation.

[45]  Farrokh Janabi-Sharifi,et al.  Model-Based Force Estimation for Intracardiac Catheters , 2016, IEEE/ASME Transactions on Mechatronics.

[46]  Pierre E. Dupont,et al.  Steering a Multi-armed Robotic Sheath Using Eccentric Precurved Tubes , 2019, 2019 International Conference on Robotics and Automation (ICRA).

[47]  Mahdi Tavakoli,et al.  Ultrasound image guidance and robot impedance control for beating-heart surgery , 2018, Control Engineering Practice.