Fabrication of cantilevers with high yield for magnetic resonance force microscopy

A fabrication method of ultra-sensitive cantilevers with high yield of almost 100% is presented. The oxide layer of an SOI wafer is patterned before the bulk silicon etching. It would break at the patterned place, while the bulk etching was to the end, which could avoid the cantilevers breaking. The SOI wafer is putted in a PTFE container during etching and cleaning. We moved the container from liquid to liquid instead of moving the wafer. These two steps ensured the high yield of almost 100% of the cantilevers. The cantilevers could detect forces as small as 10−17 N/Hz1/2 with dimensions of 465×10×0.47μm3 in a vacuum chamber at room temperature. The force sensitivity is believed to be much better at low temperature. The field gradient of three types of magnets is researched based on simulation. A conical magnet with small dimensions would be a good choice for spin moment detection in MRFM applications.

[1]  G. Boero,et al.  Highly Sensitive Cantilevers, with and without Magnetic Tip, for Magnetic Resonance Force Microscopy , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[2]  M. Despont,et al.  Fabrication of ultrafloppy single-crystal silicon cantilever for magnetic resonance imaging , 2005, IEEE Sensors, 2005..

[3]  S. R. Garner,et al.  Batch fabrication and characterization of ultrasensitive cantilevers with submicron magnetic tips , 2004 .

[4]  M. Esashi,et al.  Mechanical behavior of ultrathin microcantilever , 2000 .

[5]  D. Rugar,et al.  Mass-loaded cantilevers with suppressed higher-order modes for magnetic resonance force microscopy , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[6]  D. Mounce,et al.  Magnetic resonance force microscopy , 2005, IEEE Instrumentation & Measurement Magazine.

[7]  Peter Vettiger,et al.  Instrumental aspects of magnetic resonance force microscopy , 1998 .

[8]  T. Kenny,et al.  Quality factors in micron- and submicron-thick cantilevers , 2000, Journal of Microelectromechanical Systems.

[9]  D. Rugar,et al.  Nanoscale magnetic resonance imaging , 2009, Proceedings of the National Academy of Sciences.

[10]  Jürgen Brugger,et al.  Combined Al-protection and HF-vapor release process for ultrathin single crystal silicon cantilevers , 2006 .

[11]  M. Esashi,et al.  Energy dissipation in submicrometer thick single-crystal silicon cantilevers , 2002 .

[12]  B. Chui,et al.  Single spin detection by magnetic resonance force microscopy , 2004, Nature.

[13]  Thomas W. Kenny,et al.  Adventures in attonewton force detection , 2001 .

[14]  T. Kenny,et al.  Attonewton force detection using ultrathin silicon cantilevers , 1997 .