Differential optical spectropolarimetric imaging system assisted by liquid crystal devices for skin imaging.

Skin cancer diagnosis depends not only on histopathological examination but also on visual inspection before and after the excision of suspected lesion. Neoplasm is accompanied with changes in birefringence of collagen, pleomorphicity, and hyperchromatic state of epithelial nuclei. These phenomena can be measured by spectral and polarization changes of light backscattered by the examined tissue. A new differential spectropolarimetric system is proposed using liquid crystal devices, one as a tunable filter and the other as a polarization rotator, both operating at wide spectral ranges from the visible to the near-infrared. Since collagen's fibrils texture orientation depends on its location in the skin and since it is not well organized, our system scans the bipolarization states by continuously rotating the linearly polarized light incident on a skin lesion, and collecting differential contrasts between sequenced images when simultaneously averaging the statistical readout of a video camera. This noninvasive method emphasizes areas on skin where the neoplasm, or tumor, minimizes the statistical polarization change of the scattered light from the lesion. The module can be considered as an assistant tool for epiluminescence microscopy. Images of skin tumors were captured in vivo before the patients having their surgery and compared to histopathological results.

[1]  J. Philip,et al.  Improved optical discrimination of skin with polarized light , 1988 .

[2]  Michael S. Feld,et al.  Polarized light scattering spectroscopy for quantitative measurement of epithelial cellular structures in situ , 1999 .

[3]  R. Anderson Polarized light examination and photography of the skin. , 1991, Archives of dermatology.

[4]  Jessica C Ramella-Roman,et al.  Imaging skin pathology with polarized light. , 2002, Journal of biomedical optics.

[5]  Jessica C. Ramella-Roman,et al.  Out-of-plane polarimetric imaging of skin: surface and subsurface effects , 2005, SPIE BiOS.

[6]  J. A. Parrish,et al.  Optical radiation transfer in the human skin and applications in in vivo remittance spectroscopy , 1981 .

[7]  YNGVE ÖHMAN,et al.  A New Monochromator , 1938, Nature.

[8]  Chun Ye,et al.  Construction of an optical rotator using quarter-wave plates and an optical retarder , 1995 .

[9]  Ofir Aharon,et al.  Liquid crystal tunable filters and polarization controllers for biomedical optical imaging , 2008, Organic Photonics + Electronics.

[10]  Guillermo Aguilar,et al.  Determination of human skin optical properties from spectrophotometric measurements based on optimization by genetic algorithms. , 2005, Journal of biomedical optics.

[11]  I. Abdulhalim Dispersion relations for liquid crystals using the anisotropic Lorentz model with geometrical effects , 2006 .

[12]  Antonello De Martino,et al.  Mueller polarimetric imaging system with liquid crystals. , 2004, Applied optics.

[13]  Ibrahim Abdulhalim,et al.  Approximate analytic solutions for the director profile of homogeneously aligned nematic liquid crystals , 2010 .

[14]  Ken Lee,et al.  Design, testing, and clinical studies of a handheld polarized light camera. , 2004, Journal of biomedical optics.

[15]  R. Anderson,et al.  The optics of human skin. , 1981, The Journal of investigative dermatology.

[16]  Evolution of speckle during spinodal decomposition. , 1999, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[17]  Ibrahim Abdulhalim,et al.  Liquid crystal wavelength-independent continuous polarization rotator , 2010 .

[18]  Ofir Aharon,et al.  Liquid crystal Lyot tunable filter with extended free spectral range. , 2009, Optics express.

[19]  M. Adams,et al.  Optical waves in crystals , 1984, IEEE Journal of Quantum Electronics.

[20]  S. Elston Optics and Nonlinear Optics of Liquid Crystals , 1994 .

[21]  Quinn Smithwick,et al.  Polarimetric imaging and blood vessel quantification. , 2004, Optics express.

[22]  Ibrahim Abdulhalim,et al.  Biomedical Optical Applications of Liquid Crystal Devices , 2007 .

[23]  T. Vicsek,et al.  Transitions in a self-propelled-particles model with coupling of accelerations. , 2009, Physical review. E, Statistical, nonlinear, and soft matter physics.

[24]  Mackie,et al.  Clinical accuracy of the diagnosis of cutaneous malignant melanoma , 1998, The British journal of dermatology.

[25]  D. Cheresh,et al.  Integrin alpha v beta 3 rescues melanoma cells from apoptosis in three-dimensional dermal collagen. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[26]  Anna N Yaroslavsky,et al.  Demarcation of nonmelanoma skin cancer margins in thick excisions using multispectral polarized light imaging. , 2003, The Journal of investigative dermatology.

[27]  Michael S. Feld,et al.  Imaging human epithelial properties with polarized light-scattering spectroscopy , 2001, Nature Medicine.

[28]  A. Lien,et al.  Extended Jones matrix representation for the twisted nematic liquid‐crystal display at oblique incidence , 1990 .