Development of a potassium-selective optode for hydroponic nutrient solution monitoring.

Highly efficient and reliable plant growth such as that required in biological life support systems for future space-based missions can be better achieved with knowledge of ion concentrations within the hydroponic nutrient solution. This paper reports on the development and application of ion-selective bulk optodes to plant growth systems. Membranes for potassium-selective sensing are reported that have been tailored so that their dynamic range is centred on potassium activities within typical nutrient solution recipes. The developed sensors have been shown to exhibit a potassium activity measuring range from 0.134 to 117 mM at pH 6.0. These bulk optodes show full scale response on the order of several minutes. They show minimal interference to other cations and meet worst-case selectivity requirements for potassium monitoring in the considered half strength Hoagland solution. When continuously immersed in nutrient solution, these sensors demonstrated predicable lifetimes on the order of 50h. The developed instrument for absorption-based measurements including light source, mini-spectrometer and optode probe is presented. Custom instrument control and monitoring software including a spectral normalization procedure, use of a dual-wavelength absorbance ratio technique and automatic adjustment for pH variation result in an instrument that is self-calibrating and one that can account for effects such as light source fluctuations, membrane thickness variations and a variety of other factors. The low mass, low volume nature of bulk optode sensing systems, make them a promising technology for future space-based plant production systems. Their low-cost and technology transfer potential suggest that they could provide terrestrial growers a new and reliable mechanism to obtain ion-selective knowledge of their nutrient solution, improving yields, reducing costs and aiding in compliance to continually more stringent environmental regulation.

[1]  O. Wolfbeis,et al.  pH-Insensitive Ion Selective Optode: A Coextraction-Based Sensor for Potassium Ions , 1999 .

[2]  K. Tohda,et al.  Fibre-optic potassium ion sensors based on a neutral ionophore and a novel lipophilic anionic dye , 1990 .

[3]  Hideaki Hisamoto,et al.  Ion sensing film optodes: disposable ion sensing probes for the determination of Na+, K+, Ca2+ and Cl− concentrations in serum , 1995 .

[4]  H.J.J. Janssen,et al.  Hydrion-line, towards a closed system for water and nutrients : feedback control of water and nutrients in the drain , 2005 .

[5]  George P. Anipsitakis,et al.  Transition metal/UV-based advanced oxidation technologies for water decontamination , 2004 .

[6]  A W Galston,et al.  Photosynthesis as a basis for life support on Earth and in space: photosynthesis and transpiration in enclosed spaces. , 1992, Bioscience.

[7]  C. J. Ritsema,et al.  Estimation of activity coefficients of individual ions in solutions with ionic strengths up to 0.3 mol dm−3 , 1993 .

[8]  P. C. Meier Two-parameter debye-hückel approximation for the evaluation of mean activity coefficients of 109 electrolytes , 1982 .

[9]  K. Seiler,et al.  Theoretical aspects of bulk optode membranes , 1992 .

[10]  W. Voogt,et al.  NUTRIENT UPTAKE OF YEAR ROUND TOMATO CROPS , 1993 .

[11]  F. Szoka,et al.  Fibre optic sensor for the detection of potassium using fluorescence energy transfer. , 1990, The Analyst.

[12]  O. Wolfbeis,et al.  Novel type of ion-selective fluorosensor based on the inner filter effect: an optrode for potassium , 1993 .

[13]  Luis Fermín Capitán-Vallvey,et al.  A disposable single-use optical sensor for potassium determination based on neutral ionophore , 2003 .

[14]  A. Sanz-Medel,et al.  Serum analysis for potassium ions using a fibre optic sensor. , 1992, Clinica chimica acta; international journal of clinical chemistry.

[15]  D. B. Gomis,et al.  Ion-pair extraction and fluorimetric determination of potassium with 18-crown-6 and eosin. , 1981, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[16]  M. Meisters,et al.  Studies in the tetraarylborates , 1970 .

[17]  Eddie Schrevens,et al.  Elemental bioavailability in nutrient solutions in relation to precipitation reactions , 1998 .

[18]  E. Bakker,et al.  Synthesis and characterization of neutral hydrogen ion-selective chromoionophores for use in bulk optodes , 1993 .

[19]  E. A. Van Os,et al.  ENGINEERING AND ENVIRONMENTAL ASPECTS OF SOILLESS GROWING SYSTEMS , 1995 .

[20]  C. de Kreij,et al.  LATEST INSIGHTS INTO WATER AND NUTRIENT CONTROL IN SOILLESS CULTIVATION , 1995 .

[21]  A. Leitner,et al.  Optical sensors. Part 23. Effect of Langmuir-Blodgett layer composition on the response of ion-selective optrodes for potassium, based on the fluorimetric measurement of membrane potential , 1988 .

[22]  N. Chaniotakis,et al.  Lifetime of neutral-carrier-based liquid membranes in aqueous samples and blood and the lipophilicity of membrane components. , 1991, Analytical chemistry.

[23]  Leo F. M. Marcelis,et al.  Response of growth of tomato to phosphorus and nitrogen nutrition , 2004 .

[24]  O. Wolfbeis,et al.  Fluorescent potential-sensitive dyes for use in solid state sensors for potassium ion , 1996 .

[25]  Juergen Polster,et al.  Contributions to potassium and ammonium ion-selective optodes based on valinomycin, nonactin, and 1,1-dimethylsila-20-crown-7 , 1995, European Symposium on Optics for Environmental and Public Safety.

[26]  A Zipp,et al.  Solid-phase colorimetric determination of potassium. , 1982, Clinical chemistry.

[27]  Peter C. Hauser,et al.  Flow-injection analysis with bulk extraction based optical sensor membranes , 1994 .

[28]  A. Sanz-Medel,et al.  A comparative study of two different approaches for active optical sensing of potassium with a chromoionophore , 1993 .

[29]  B. Ágai,et al.  Synthesis and characterization of covalently immobilized bis-crown ether based potassium ionophore. , 2005, The Analyst.

[30]  Mohammad Reza Ganjali,et al.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade , 2008, Sensors.

[31]  M B Tabacco,et al.  Optical sensors for monitoring and control of plant growth systems. , 1994, Advances in space research : the official journal of the Committee on Space Research.

[32]  E. A. van Os,et al.  DIURNAL CHANGES IN THE ION CONCENTRATION OF THE SUPPLY AND RETURN WATER OF A TOMATO CROP GROWN ON ROCKWOOL , 1992 .

[33]  Otto S. Wolfbeis,et al.  Optical sensors: An ion-selective optrode for potassium , 1987 .

[34]  Luis Fermín Capitán-Vallvey,et al.  Potassium disposable optical sensor based on transflectance and cromaticity measurements , 2007 .

[35]  K. Seiler,et al.  Determination of complex formation constants of neutral cation-selective ionophores in solvent polymeric membranes , 1994 .

[36]  J. E. Harper,et al.  Seasonal Nutrient Uptake and Accumulation Patterns in Soybeans1 , 1971 .

[37]  A. Sanz-Medel,et al.  Potassium-selective optrode based on an immobilized fluorogenic crown ether , 1994 .

[38]  E. Bakker,et al.  Selectivity of ion-sensitive bulk optodes , 1992 .

[39]  Helmut Offenbacher,et al.  Fluorescence optical sensors for continuous determination of near-neutral pH values , 1986 .

[40]  E. Akkaya,et al.  Fiber optic sodium and potassium sensing by using a newly synthesized squaraine dye in PVC matrix. , 2002, Talanta.

[41]  C. J. Asher,et al.  pH optima for crop growth , 2005, Plant and Soil.

[42]  K. Seiler,et al.  Carriers for chemical sensors: Design features of optical sensors (optodes) based on selective chromoionophores , 1989 .

[43]  K. Ueno,et al.  Complexation and extraction of alkali metal ions by 4'-picrylaminobenzo-18-crown-6 derivatives , 1980 .

[44]  Michael R. Shortreed,et al.  Development of a fluorescent optical potassium-selective ion sensor with ratiometric response for intracellular applications , 1997 .

[45]  A. Smith,et al.  Soil Science , 1965, Nature.

[46]  Rita Grosch,et al.  Water quality assessment of different reservoir types in relation to nutrient solution use in hydroponics , 2005 .

[47]  M. Tabacco,et al.  Optical chemical sensors for environmental control and system management. , 1996, Advances in Space Research.

[48]  Ernö Pretsch,et al.  Carrier-Based Ion-Selective Electrodes and Bulk Optodes. 1. General Characteristics. , 1997, Chemical reviews.

[49]  Gerhard Heinzmann,et al.  Development of a submicron optochemical potassium sensor with enhanced stability due to internal reference , 1998 .

[50]  Eric Bakker,et al.  Perbrominated closo-dodecacarborane anion, 1-HCB11Br11-, as an ion exchanger in cation-selective chemical sensors. , 2002, Analytical chemistry.

[51]  R M Wheeler,et al.  Excess nutrients in hydroponic solutions alter nutrient content of rice, wheat, and potato. , 1996, Advances in space research : the official journal of the Committee on Space Research.

[52]  K. Ueno,et al.  A Novel Colorimetric Reagent for Potassium Based on Crown Ether Complex Formation , 1977 .

[53]  Bruce Bugbee,et al.  Nutrient Management in Recirculating Hydroponic Culture , 2004 .

[54]  K. Seiler,et al.  Characterization of Potassium-Selective Optode Membranes Based on Neutral Ionophores and Application in Human Blood Plasma , 1990 .

[55]  Jonathan Smith,et al.  Hydroponics: A Practical guide for the Soilless Grower , 2005 .

[56]  L.J.S. Lukasse,et al.  Monitoring and control of water and fertilizer distribution in Greenhouses , 1995 .

[57]  Yoshio Umezawa,et al.  Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report) , 2008 .

[58]  D. R. Hoagland,et al.  The Water-Culture Method for Growing Plants Without Soil , 2018 .

[59]  Liz,et al.  Crop Production for Advanced Life Support Systems: Observations from the Kennedy Space Center Breadboard Project , 2013 .

[60]  G. Nagy,et al.  Planar waveguide ion-selective sensors , 1997 .

[61]  W. Chan,et al.  Potassium ion-selective optodes based on the calix[6]arene hexaester and application in human serum assay. , 1996, The Analyst.

[62]  E. Pretsch,et al.  Lipophilicity of tetraphenylborate derivatives as anionic sites in neutral carrier-based solvent polymeric membranes and lifetime of corresponding ion-selective electrochemical and optical sensors , 1995 .

[63]  K. Ueno,et al.  New convenient colorimetric determination of patassium in blood serum. , 1977, Talanta.

[64]  Y. Kawabata,et al.  Fiber-optic potassium ion sensor using alkyl-acridine orange in plasticized poly(vinyl chloride) membrane , 1990 .

[65]  E. Bakker,et al.  Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensors , 1993 .

[66]  B. Ágai,et al.  Novel bis (crown ether)-based potassium sensor for biological applications , 1990 .

[67]  H.J.J. Janssen,et al.  ISE and chemfet sensors in greenhouse cultivation , 2005 .

[68]  W. Voogt,et al.  THE GROWTH OF BEEFSTEAK TOMATO AS AFFECTED BY K/CA RATIOS IN THE NUTRIENT SOLUTION , 1988 .

[69]  J. C. Forbes,et al.  Plants in Agriculture , 1992 .

[70]  C. Savage,et al.  Closed Ecological Systems , 1994 .

[71]  Farm Buildings,et al.  Ministry of Agriculture, Fisheries and Food- , 1956 .