Inclusion of thin target and source regions in alimentary and respiratory tract systems of mesh-type ICRP adult reference phantoms

It is not feasible to define very small or complex organs and tissues in the current voxel-type adult reference computational phantoms of the International Commission on Radiological Protection (ICRP), which limit dose coefficients for weakly penetrating radiations. To address the problem, the ICRP is converting the voxel-type reference phantoms into mesh-type phantoms. In the present study, as a part of the conversion project, the micrometer-thick target and source regions in the alimentary and respiratory tract systems as described in ICRP Publications 100 and 66 were included in the mesh-type ICRP reference adult male and female phantoms. In addition, realistic lung airway models were simulated to represent the bronchial (BB) and bronchiolar (bb) regions. The electron specific absorbed fraction (SAF) values for the alimentary and respiratory tract systems were then calculated and compared with the values calculated with the stylized models of ICRP Publications 100 and 66. The comparisons show generally good agreement for the oral cavity, oesophagus, and BB, whereas for the stomach, small intestine, large intestine, extrathoracic region, and bb, there are some differences (e.g. up to ~9 times in the large intestine). The difference is mainly due to anatomical difference in these organs between the realistic mesh-type phantoms and the simplified stylized models. The new alimentary and respiratory tract models in the mesh-type ICRP reference phantoms preserve the topology and dimensions of the voxel-type ICRP phantoms and provide more reliable SAF values than the simplified models adopted in previous ICRP Publications.

[1]  Hang Si,et al.  TetGen, a Delaunay-Based Quality Tetrahedral Mesh Generator , 2015, ACM Trans. Math. Softw..

[2]  J. Valentin Basic anatomical and physiological data for use in radiological protection: reference values , 2002, Annals of the ICRP.

[3]  N Shandala,et al.  Scope of radiological protection control measures. , 2007, Annals of the ICRP.

[4]  N Petoussi-Henss,et al.  Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures , 2010, Annals of the ICRP.

[5]  Deanna Hasenauer,et al.  Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models , 2007, Physics in medicine and biology.

[6]  R. Vetter ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection , 2008 .

[7]  Y S Yeom,et al.  The reference phantoms: voxel vs polygon , 2016, Annals of the ICRP.

[8]  C. Potter ICRP Publication 100 Human Alimentary Tract Model for Radiological Protection. , 2007 .

[9]  Min Cheol Han,et al.  Tetrahedral-mesh-based computational human phantom for fast Monte Carlo dose calculations , 2014, Physics in medicine and biology.

[10]  J. Apostolakis,et al.  Parallel geometries in Geant4: Foundation and recent enhancements , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[11]  Icrp Human Respiratory Tract Model for Radiological Protection , 1994 .

[12]  Paolo Cignoni,et al.  Generating Random Points in a Tetrahedron , 2000, J. Graphics, GPU, & Game Tools.

[13]  Chan Hyeong Kim,et al.  New small-intestine modeling method for surface-based computational human phantoms , 2016, Journal of radiological protection : official journal of the Society for Radiological Protection.

[14]  Min Cheol Han,et al.  Development of skeletal system for mesh-type ICRP reference adult phantoms , 2016, Physics in medicine and biology.

[15]  A. Dell'Acqua,et al.  Geant4 - A simulation toolkit , 2003 .

[16]  R Behrens,et al.  Dose conversion coefficients for electron exposure of the human eye lens. , 2009, Physics in medicine and biology.

[17]  J. H. Hubbell,et al.  Tables and graphs of atomic subshell and relaxation data derived from the LLNL Evaluated Atomic Data Library (EADL), Z=1-100 , 1991 .

[18]  Icrp Chapters 3 and 4 , 2007 .

[19]  Chan Hyeong Kim,et al.  Incorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantoms , 2015, Physics in medicine and biology.

[20]  Chan Hyeong Kim,et al.  A polygon-surface reference Korean male phantom (PSRK-Man) and its direct implementation in Geant4 Monte Carlo simulation , 2011, Physics in medicine and biology.

[21]  Paul DeLuca,et al.  Realistic reference phantoms: An ICRP/ICRU joint effort , 2009, Annals of the ICRP.

[22]  P. J. Hunter,et al.  Generation of an Anatomically Based Three-Dimensional Model of the Conducting Airways , 2000, Annals of Biomedical Engineering.

[23]  N Petoussi-Henss,et al.  ICRP Publication 133: The ICRP computational framework for internal dose assessment for reference adults: specific absorbed fractions , 2016, Annals of the ICRP.

[24]  Min Cheol Han,et al.  Conversion of ICRP male reference phantom to polygon-surface phantom , 2013, Physics in medicine and biology.

[25]  Stephen M. Seltzer,et al.  Tables and Graphs of Electron-Interaction Cross Sections from 10 eV to 100 GeV Derived from the LLNL Evaluated Data Library (EEDL), Z=1-100 | NIST , 1991 .

[26]  J. Harrison,et al.  ICRP Publication 130: Occupational Intakes of Radionuclides: Part 1 , 2015, Annals of the ICRP.