An Independent Active Contours Segmentation framework for bone micro-CT images

Micro-CT is an imaging technique for small tissues and objects that is gaining increased popularity especially as a pre-clinical application. Nevertheless, there is no well-established micro-CT segmentation method, while typical procedures lack sophistication and frequently require a degree of manual intervention, leading to errors and subjective results. To address these issues, a novel segmentation framework, called Independent Active Contours Segmentation (IACS), is proposed in this paper. The proposed IACS is based on two autonomous modules, namely automatic ROI extraction and IAC Evolution, which segments the ROI image using multiple Active Contours that evolve simultaneously and independently of one another. The proposed method is applied on a Phantom dataset and on real datasets. It is tested against several established segmentation methods that include Adaptive Thresholding, Otsu Thresholding, Region Growing, Chan-Vese (CV) AC, Geodesic AC and Automatic Local Ratio-CV AC, both qualitatively and quantitatively. The results prove its superior performance in terms of object identification capability, accuracy and robustness, under normal circumstances and under four types of artificially introduced noise. These enhancements can lead to more reliable analysis, better diagnostic procedures and treatment evaluation of several bone-related pathologies, and to the facilitation and further advancement of bone research.

[1]  Ralph Müller,et al.  Guidelines for assessment of bone microstructure in rodents using micro–computed tomography , 2010, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[2]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[3]  David D. McErlain,et al.  Study of subchondral bone adaptations in a rodent surgical model of OA using in vivo micro-computed tomography. , 2008, Osteoarthritis and cartilage.

[4]  Pierre Weiss,et al.  Micro-CT Analysis of Radiation-Induced Osteopenia and Bone Hypovascularization in Rat , 2015, Calcified Tissue International.

[5]  L Cristofolini,et al.  A physical phantom for the calibration of three‐dimensional X‐ray microtomography examination , 2006, Journal of microscopy.

[6]  Guillermo Sapiro,et al.  Geodesic Active Contours , 1995, International Journal of Computer Vision.

[7]  Ming Ding,et al.  Age‐related variations in the microstructure of human tibial cancellous bone , 2002, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  Paul L. Rosin Unimodal thresholding , 2001, Pattern Recognit..

[9]  Nicolas Coudray,et al.  Robust threshold estimation for images with unimodal histograms , 2010, Pattern Recognit. Lett..

[10]  I Lima,et al.  Ethanol bone evaluation using 3D microtomography. , 2008, Micron.

[11]  M Ding,et al.  Accuracy of cancellous bone volume fraction measured by micro-CT scanning. , 1999, Journal of biomechanics.

[12]  W. Clem Karl,et al.  Real-time tracking using level sets , 2005, 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05).

[13]  C T Badea,et al.  Micro-CT of rodents: state-of-the-art and future perspectives. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[14]  Steven K Boyd,et al.  Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis. , 2007, Bone.

[15]  G. Zack,et al.  Automatic measurement of sister chromatid exchange frequency. , 1977, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[16]  G K Matsopoulos,et al.  Influence of segmentation on micro‐CT images of trabecular bone , 2014, Journal of microscopy.

[17]  Benjamin Wu,et al.  MicroCT evaluation of three-dimensional mineralization in response to BMP-2 doses in vitro and in critical sized rat calvarial defects. , 2007, Tissue engineering.

[18]  Scott D. Roth,et al.  Ray casting for modeling solids , 1982, Comput. Graph. Image Process..

[19]  Wilhelm Burger,et al.  Digital Image Processing - An Algorithmic Introduction using Java , 2008, Texts in Computer Science.

[20]  Dietmar W Hutmacher,et al.  Analysis of 3D bone ingrowth into polymer scaffolds via micro-computed tomography imaging. , 2004, Biomaterials.

[21]  Demetri Terzopoulos,et al.  Snakes: Active contour models , 2004, International Journal of Computer Vision.

[22]  Jui-Ting Hsu,et al.  The assessment of trabecular bone parameters and cortical bone strength: a comparison of micro-CT and dental cone-beam CT. , 2013, Journal of biomechanics.

[23]  Lei Zhang,et al.  Active contours with selective local or global segmentation: A new formulation and level set method , 2010, Image Vis. Comput..

[24]  D. Mumford,et al.  Optimal approximations by piecewise smooth functions and associated variational problems , 1989 .

[25]  Weifeng Li,et al.  Active contours driven by local and global probability distributions , 2013, J. Vis. Commun. Image Represent..

[26]  Parasuraman Padmanabhan,et al.  Stem cell‐mediated accelerated bone healing observed with in vivo molecular and small animal imaging technologies in a model of skeletal injury , 2009, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[27]  Heike Scherf,et al.  A new high-resolution computed tomography (CT) segmentation method for trabecular bone architectural analysis. , 2009, American journal of physical anthropology.

[28]  Christian Vanhove,et al.  In vivo longitudinal micro-CT study of bent long limb bones in rat offspring. , 2014, Reproductive toxicology.

[29]  J. Sethian,et al.  Fronts propagating with curvature-dependent speed: algorithms based on Hamilton-Jacobi formulations , 1988 .

[30]  R. Huiskes,et al.  The influence of microcomputed tomography threshold variations on the assessment of structural and mechanical trabecular bone properties. , 2002, Bone.

[31]  Fabio Baruffaldi,et al.  Mechanical testing of cancellous bone from the femoral head: experimental errors due to off-axis measurements. , 2007, Journal of biomechanics.

[32]  Françoise Peyrin,et al.  3D osteocyte lacunar morphometric properties and distributions in human femoral cortical bone using synchrotron radiation micro-CT images. , 2014, Bone.

[33]  M Viceconti,et al.  MicroCT examination of human bone specimens: effects of polymethylmethacrylate embedding on structural parameters , 2007, Journal of microscopy.

[34]  Anthony J. Yezzi,et al.  Curve evolution implementation of the Mumford-Shah functional for image segmentation, denoising, interpolation, and magnification , 2001, IEEE Trans. Image Process..

[35]  Dietmar W Hutmacher,et al.  A comparison of micro CT with other techniques used in the characterization of scaffolds. , 2006, Biomaterials.

[36]  Miss A.O. Penney (b) , 1974, The New Yale Book of Quotations.

[37]  Simone Tassani,et al.  The micro-structure of bone trabecular fracture: an inter-site study. , 2014, Bone.

[38]  S. Majumdar,et al.  The Temporal Changes of Trabecular Architecture in Ovariectomized Rats Assessed by MicroCT , 2001, Osteoporosis International.

[39]  Yun Tian,et al.  Active contour model combining region and edge information , 2011, Machine Vision and Applications.

[40]  Bülent Sankur,et al.  Survey over image thresholding techniques and quantitative performance evaluation , 2004, J. Electronic Imaging.

[41]  J. Kinney,et al.  In vivo, three‐dimensional microscopy of trabecular bone , 1995, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[42]  P. Rüegsegger,et al.  A microtomographic system for the nondestructive evaluation of bone architecture , 2006, Calcified Tissue International.

[43]  R Müller,et al.  Effects of Daily Treatment with Parathyroid Hormone on Bone Microarchitecture and Turnover in Patients with Osteoporosis: A Paired Biopsy Study * , 2001, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[44]  Tony F. Chan,et al.  Active contours without edges , 2001, IEEE Trans. Image Process..

[45]  George K. Matsopoulos,et al.  Automatic local parameterization of the Chan Vese active contour model's force coefficients using edge information , 2015, J. Vis. Commun. Image Represent..

[46]  N. Otsu A threshold selection method from gray level histograms , 1979 .