Novel interleaved spiral imaging motion correction technique using orbital navigators

Although spiral imaging seldom produces apparent artifacts related to flow, it remains sensitive to rapid object motion. In this article, a new correction method is presented for rapid rigid body motion in interleaved spiral imaging. With this technique, an identical circular navigator k‐space trajectory is linked to each spiral trajectory. Data inconsistency due to both rotation and translation among spiral interleaves can be corrected by evaluating the magnitudes and phases of the data contained in the navigator “ring.” Further, it is difficult to create a frequency field map for off‐resonance correction when an object moves during a scan, because there is motion‐dependent misregistration between the two images acquired with different TEs. However, this difficulty can be overcome by combining the motion‐correction method with a recently proposed technique (off‐resonance correction using variable‐density spirals (ORC‐VDS)), thereby enabling both motion compensation and off‐resonance correction with no additional scanning. Magn Reson Med 50:423–428, 2003. © 2003 Wiley‐Liss, Inc.

[1]  D G Nishimura,et al.  A Velocity k‐Space Analysis of Flow Effects in Echo‐Planar and Spiral Imaging , 1995, Magnetic resonance in medicine.

[2]  A Shankaranarayanan,et al.  Two‐step navigatorless correction algorithm for radial k‐space MRI acquisitions , 2001, Magnetic resonance in medicine.

[3]  D G Nishimura,et al.  Efficient off‐resonance correction for spiral imaging , 2001, Magnetic resonance in medicine.

[4]  S J Riederer,et al.  A prospective approach to correct for inter‐image head rotation in FMRI , 1998, Magnetic resonance in medicine.

[5]  J C Gore,et al.  Analysis and correction of motion artifacts in diffusion weighted imaging , 1994, Magnetic resonance in medicine.

[6]  Weili Lin,et al.  Principles of magnetic resonance imaging: a signal processing perspective [Book Review] , 2000 .

[7]  J L Duerk,et al.  Modified block uniform resampling (BURS) algorithm using truncated singular value decomposition: Fast accurate gridding with noise and artifact reduction , 2001, Magnetic resonance in medicine.

[8]  Clifford R. Jack,et al.  Spherical navigator echoes for full 3D rigid body motion measurement in MRI , 2001, SPIE Medical Imaging.

[9]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[10]  Todd S. Sachs,et al.  Real‐time motion detection in spiral MRI using navigators , 1994, Magnetic resonance in medicine.

[11]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[12]  Hermann Schomberg,et al.  Off-resonance correction of MR images , 1999, IEEE Transactions on Medical Imaging.

[13]  N J Pelc,et al.  Reduction of motion artifacts in cine MRI using variable‐density spiral trajectories , 1997, Magnetic resonance in medicine.

[14]  David Atkinson,et al.  Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion , 1997, IEEE Transactions on Medical Imaging.

[15]  J. Felmlee,et al.  Orbital navigator echoes for motion measurements in magnetic resonance imaging , 1995, Magnetic resonance in medicine.