Pericardial heterograft valves: an assessment of leaflet stresses and their implications for heart valve design.

Bovine pericardium, stabilized with glutaraldehyde, is used widely in the construction of heart valve substitutes, but the design and construction of valve substitutes from this material are empirically based. Collagenous tissue can support tension, but experimental evidence indicates that flexure-induced compressive stresses can lead to fatigue failure. This study uses experimental results obtained from cyclic uniaxial load tests to predict the type and magnitude of operational stresses which occur in pericardial heterograft leaflets. Both Young's modulus and Poisson's ratio varied with uniaxial loading in pericardium, chemically modified free of tension. Leaflet stresses were analysed in using effective incremental representations of these parameters. In leaflets with unrestricted rotation at the point of attachment to the stent, the mid-plane tensions always exceeded the bending stresses, and no zones of leaflet compression were predicted. In contrast, with totally restricted leaflet rotation induced by clamping (possibly between a male and female frame) the bending stresses were greater than the mid-plane tensions at the hinge line and significant compressive stresses were predicted at this site. If elastic boundary conditions were introduced at the stent (possibly by wrapping the stent in pericardium) then the compressive stresses were reduced as the degree of elasticity was increased. Glutaraldehyde fixation of the pericardium under load produced a stiffer material; higher compressive stresses at the stent and significant increases in total stress were predicted for this tissue. The application of elevated pressure loading also increased the compressive and total stresses in the leaflet. Finally, it was shown that bicuspid leaflets were likely to experience higher stresses than tricuspid leaflets. This simple stress analysis should help valve designers of pericardial heterografts to identify those conditions which lead to tissue compression, high total stress, and ultimately material fatigue.

[1]  E. Trowbridge,et al.  Evidence that deformations which occur during mechanical conditioning of bovine pericardium are not permanent. , 1986, Biomaterials.

[2]  D R Boughner,et al.  The glutaraldehyde-stabilized porcine aortic valve xenograft. II. Effect of fixation with or without pressure on the tensile viscoelastic properties of the leaflet material. , 1984, Journal of Biomedical Materials Research.

[3]  M. Thubrikar,et al.  Analysis of the design and dynamics of aortic bioprostheses in vivo. , 1982, The Journal of thoracic and cardiovascular surgery.

[4]  M. Thubrikar,et al.  Stresses of natural versus prosthetic aortic valve leaflets in vivo. , 1980, The Annals of thoracic surgery.

[5]  E A Trowbridge,et al.  The extension rate independence of the hysteresis in glutaraldehyde-fixed bovine pericardium. , 1987, Biomaterials.

[6]  E. A. Trowbridge,et al.  The mechanical response of glutaraldehyde-fixed bovine pericardium to uniaxial load , 1985 .

[7]  S. Timoshenko,et al.  THEORY OF PLATES AND SHELLS , 1959 .

[8]  M. Ionescu,et al.  Frame-mounted tissue heart valves: technique of construction , 1974, Thorax.

[9]  N. Broom,et al.  Fatigue-induced damage in glutaraldehyde-preserved heart valve tissue. , 1978, The Journal of thoracic and cardiovascular surgery.

[10]  R. van Noort,et al.  The physical properties of bovine pericardium: a study of the effects of stretching during chemical treatment in glutaraldehyde. , 1982, The Annals of thoracic surgery.

[11]  P. J. Drury,et al.  Twenty-Five Years of Heart Valve Substitutes: A Review1 , 1983, Journal of the Royal Society of Medicine.

[12]  J. Strom,et al.  Fatigue-induced failure of the Ionescu-Shiley pericardial xenograft in the mitral position. In vivo and in vitro correlation and a proposed classification. , 1984, The Journal of thoracic and cardiovascular surgery.