Two-dimensional shear-wave elastography on conventional ultrasound scanners with time-aligned sequential tracking (TAST) and comb-push ultrasound shear elastography (CUSE)

Two-dimensional shear-wave elastography presents 2-D quantitative shear elasticity maps of tissue, which are clinically useful for both focal lesion detection and diffuse disease diagnosis. Realization of 2-D shear-wave elastography on conventional ultrasound scanners, however, is challenging because of the low tracking pulse-repetition-frequency (PRF) of these systems. Although some clinical and research platforms support software beamforming and plane-wave imaging with high PRF, the majority of current clinical ultrasound systems do not have the software beamforming capability, which presents a critical challenge for translating the 2-D shear-wave elastography technique from laboratory to clinical scanners. To address this challenge, this paper presents a time-aligned sequential tracking (TAST) method for shear-wave tracking on conventional ultrasound scanners. TAST takes advantage of the parallel beamforming capability of conventional systems and realizes high-PRF shear-wave tracking by sequentially firing tracking vectors and aligning shear wave data in the temporal direction. The comb-push ultrasound shear elastography (CUSE) technique was used to simultaneously produce multiple shear wave sources within the field-of-view (FOV) to enhance shear wave SNR and facilitate robust reconstructions of 2-D elasticity maps. TAST and CUSE were realized on a conventional ultrasound scanner. A phantom study showed that the shear-wave speed measurements from the conventional ultrasound scanner were in good agreement with the values measured from other 2-D shear wave imaging technologies. An inclusion phantom study showed that the conventional ultrasound scanner had comparable performance to a state-of-the-art shear-wave imaging system in terms of bias and precision in measuring different sized inclusions. Finally, in vivo case analysis of a breast with a malignant mass, and a liver from a healthy subject demonstrated the feasibility of using the conventional ultrasound scanner for in vivo 2-D shear-wave elastography. These promising results indicate that the proposed technique can enable the implementation of 2-D shear-wave elastography on conventional ultrasound scanners and potentially facilitate wider clinical applications with shear-wave elastography.

[1]  V. Agrawal,et al.  A parallel tracking method for acoustic radiation force impulse imaging , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  J. Greenleaf,et al.  Selected methods for imaging elastic properties of biological tissues. , 2003, Annual review of biomedical engineering.

[3]  Armando Manduca,et al.  Comb-Push Ultrasound Shear Elastography (CUSE) With Various Ultrasound Push Beams , 2013, IEEE Transactions on Medical Imaging.

[4]  G. Harris,et al.  Models and regulatory considerations for transient temperature rise during diagnostic ultrasound pulses. , 2002, Ultrasound in medicine & biology.

[5]  M. Fink,et al.  Supersonic shear imaging: a new technique for soft tissue elasticity mapping , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Zhe Wu,et al.  Sonoelastographic imaging of interference patterns for estimation of the shear velocity of homogeneous biomaterials , 2004, Physics in medicine and biology.

[7]  Robert Rohling,et al.  A high-frame-rate ultrasound system for the study of tissue motions , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Shigao Chen,et al.  Assessment of liver viscoelasticity by using shear waves induced by ultrasound radiation force. , 2013, Radiology.

[9]  M. Fink,et al.  Breast lesions: quantitative elastography with supersonic shear imaging--preliminary results. , 2010, Radiology.

[10]  J. Greenleaf,et al.  Measure elasticity and viscosity using the out-of-plane shear wave , 2012, 2012 IEEE International Ultrasonics Symposium.

[11]  Abdullah Alturki,et al.  RSNA/QIBA: Shear wave speed as a biomarker for liver fibrosis staging , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[12]  Yen-Feng Li,et al.  Software Beamforming: Comparison between a Phased Array and Synthetic Transmit Aperture , 2011, Ultrasonic imaging.

[13]  Ned C. Rouze,et al.  Noninvasive evaluation of hepatic fibrosis using acoustic radiation force-based shear stiffness in patients with nonalcoholic fatty liver disease. , 2011, Journal of hepatology.

[14]  Kevin Parker,et al.  Integration of crawling waves in an ultrasound imaging system. Part 1: system and design considerations. , 2012, Ultrasound in medicine & biology.

[15]  O H Gilja,et al.  EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography.Part 2: Clinical Applications , 2013, Ultraschall in der Medizin.

[16]  Pengfei Song,et al.  Bias observed in time-of-flight shear wave speed measurements using radiation force of a focused ultrasound beam. , 2011, Ultrasound in medicine & biology.

[17]  Mickael Tanter,et al.  Ultrafast imaging in biomedical ultrasound , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[18]  Thomas Deffieux,et al.  Quantitative assessment of breast lesion viscoelasticity: initial clinical results using supersonic shear imaging. , 2008, Ultrasound in medicine & biology.

[19]  Armando Manduca,et al.  Fast shear compounding using robust 2-D shear wave speed calculation and multi-directional filtering. , 2014, Ultrasound in medicine & biology.

[20]  G. Ferraioli,et al.  Accuracy of real‐time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: A pilot study , 2012, Hepatology.

[21]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE Transactions on Sonics and Ultrasonics.

[22]  B. Garra,et al.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING. , 2011, Current medical imaging reviews.

[23]  Marc D Weinshenker,et al.  Explososcan: a parallel processing technique for high speed ultrasound imaging with linear phased arrays. , 1984 .

[24]  Armando Manduca,et al.  Quantitative assessment of hepatic fibrosis in an animal model with magnetic resonance elastography , 2007, Magnetic resonance in medicine.

[25]  M. Fink,et al.  Shear elasticity probe for soft tissues with 1-D transient elastography , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  Kevin Parker,et al.  Integration of crawling waves in an ultrasound imaging system. Part 2: signal processing and applications. , 2012, Ultrasound in medicine & biology.

[27]  Armando Manduca,et al.  Comb-Push Ultrasound Shear Elastography (CUSE): A Novel Method for Two-Dimensional Shear Elasticity Imaging of Soft Tissues , 2012, IEEE Transactions on Medical Imaging.

[28]  Ioan Sporea,et al.  EFSUMB Guidelines and Recommendations on the Clinical , 2017 .

[29]  罗纳德·埃尔文·戴格尔 Ultrasound imaging system with pixel oriented processing , 2006 .