The high-density multiwire drift chamber

Abstract A multiwire proportional chamber, with a high-density drift space attached, has been developed as a position-sensitive detector for non-ionizing radiation. A chamber with a 5 g/cm 3 drift space, comprising a lead-bismuth matrix of 1 mm square holes on a 1.5 mm pitch has been investigated. For 0.66 MeV protons a detection efficiency of 5%, combined with a spatial resolution of 1.3 mm fwhm, is obtained. Much higher efficiencies are possible. A theoretical analysis of the detection efficiency as a function of photon energy is presented. It agrees well with experimental results. The chamber offers new possibilities for photon and neutron detection, and as a shower detector for high-energy particles.

[1]  A. T. Nelms,et al.  ENERGY LOSS AND RANGE OF ELECTRONS AND POSITRONS , 1956 .

[2]  A. H. Walenta,et al.  The multiwire drift chamber, a new type of proportional wire chamber , 1971 .

[3]  K. Sistemich,et al.  POSITION-SENSITIVE COUNTER , 1966 .

[4]  R. Chaminade,et al.  Localisation de particules par computeur à migration , 1973 .

[5]  Leon Kaufman,et al.  Characteistics of Multiwire Proportional Chambers for Positron Imaging , 1974 .

[6]  V. Radeka Signal, Noise and Resolution in Position-Sensitive Detectors , 1974 .

[7]  L. Kaufman,et al.  Multiwire proportional chambers for biomedical application , 1973 .

[8]  L. C. Spencer Energy dissipation by fast electrons , 1959 .

[9]  A Multiwire Proportional Chamber for Imaging Thermal, Epicadmium, and Fast Neutrons , 1974 .

[10]  H. Seliger The Backscattering of Positrons and Electrons , 1952 .

[11]  G. Charpak Evolution of the Automatic Spark Chambers , 1970 .

[12]  H. Bethe,et al.  Experimental Nuclear Physics , 1953 .

[13]  Gladys White Grodstein X-Ray Attenuation Coefficients from 10 KEV to 100 MEV , 1957 .

[14]  J. Cockcroft,et al.  Experimental Nuclear Physics , 1955, Nature.

[15]  L. V. Spencer,et al.  THEORY OF ELECTRON PENETRATION , 1955 .

[16]  G. Flügge,et al.  Time degeneracy of multiwire proportional chambers , 1972 .

[17]  Z. Hajduk,et al.  The Spherical Drift Chamber for X-Ray Imaging Applications , 1974, IEEE Transactions on Nuclear Science.

[18]  H. Seliger TRANSMISSION OF POSITRONS AND ELECTRONS , 1955 .

[19]  Gladys White Grodstein Circular of the Bureau of Standards no. 583:: x-ray attenuation from 10 kev to 100 Mev , 1957 .

[20]  C. J. Borkowski,et al.  Some Applications and Properties of One- and Two-Dimensional Position-Sensitive Proportional Counters , 1970 .