Functional Sensitivity of 2D Simultaneous Multi-Slice Echo-Planar Imaging: Effects of Acceleration on g-factor and Physiological Noise

Accelerated data acquisition with simultaneous multi-slice (SMS) imaging for functional MRI studies leads to interacting and opposing effects that influence the sensitivity to blood oxygen level-dependent (BOLD) signal changes. Image signal to noise ratio (SNR) is decreased with higher SMS acceleration factors and shorter repetition times (TR) due to g-factor noise penalties and saturation of longitudinal magnetization. However, the lower image SNR is counteracted by greater statistical power from more samples per unit time and a higher temporal Nyquist frequency that allows for better removal of spurious non-BOLD high frequency signal content. This study investigated the dependence of the BOLD sensitivity on these main driving factors and their interaction, and provides a framework for evaluating optimal acceleration of SMS-EPI sequences. functional magnetic resonance imaging (fMRI) data from a scenes/objects visualization task was acquired in 10 healthy volunteers at a standard neuroscience resolution of 3 mm on a 3T MRI scanner. SMS factors 1, 2, 4, and 8 were used, spanning TRs of 2800 ms to 350 ms. Two data processing methods were used to equalize the number of samples over the SMS factors. BOLD sensitivity was assessed using g-factors maps, temporal SNR (tSNR), and t-score metrics. tSNR results show a dependence on SMS factor that is highly non-uniform over the brain, with outcomes driven by g-factor noise amplification and the presence of high frequency noise. The t-score metrics also show a high degree of spatial dependence: the lower g-factor noise area of V1 shows significant improvements at higher SMS factors; the moderate-level g-factor noise area of the parahippocampal place area shows only a trend of improvement; and the high g-factor noise area of the ventral-medial pre-frontal cortex shows a trend of declining t-scores at higher SMS factors. This spatial variability suggests that the optimal SMS factor for fMRI studies is region dependent. For task fMRI studies done with similar parameters as were used here (3T scanner, 32-channel RF head coil, whole brain coverage at 3 mm isotropic resolution), we recommend SMS accelerations of 4x (conservative) to 8x (aggressive) for most studies and a more conservative acceleration of 2x for studies interested in anterior midline regions.

[1]  Nikolaus Kriegeskorte,et al.  Pattern-information analysis: From stimulus decoding to computational-model testing , 2011, NeuroImage.

[2]  J. Polimeni,et al.  Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penalty , 2012, Magnetic resonance in medicine.

[3]  Kawin Setsompop,et al.  Interslice leakage artifact reduction technique for simultaneous multislice acquisitions , 2014, Magnetic resonance in medicine.

[4]  Robin M Heidemann,et al.  Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi‐slice imaging , 2005, Magnetic resonance in medicine.

[5]  E. Maguire,et al.  Constructing, Perceiving, and Maintaining Scenes: Hippocampal Activity and Connectivity , 2014, Cerebral cortex.

[6]  Karl J. Friston,et al.  Event‐related f MRI , 1997, Human brain mapping.

[7]  Karl J. Friston,et al.  CHAPTER 2 – Statistical parametric mapping , 2007 .

[8]  Steen Moeller,et al.  The Human Connectome Project's neuroimaging approach , 2016, Nature Neuroscience.

[9]  Kawin Setsompop,et al.  Ultra-fast MRI of the human brain with simultaneous multi-slice imaging. , 2013, Journal of magnetic resonance.

[10]  Steen Moeller,et al.  Evaluation of 2D multiband EPI imaging for high-resolution, whole-brain, task-based fMRI studies at 3T: Sensitivity and slice leakage artifacts , 2016, NeuroImage.

[11]  Andrea Bergmann,et al.  Statistical Parametric Mapping The Analysis Of Functional Brain Images , 2016 .

[12]  D. Larkman,et al.  Use of multicoil arrays for separation of signal from multiple slices simultaneously excited , 2001, Journal of magnetic resonance imaging : JMRI.

[13]  Erno J. Hermans,et al.  Enhanced sensitivity with fast three‐dimensional blood‐oxygen‐level‐dependent functional MRI: comparison of SENSE–PRESTO and 2D‐EPI at 3 T , 2008, NMR in biomedicine.

[14]  Steen Moeller,et al.  Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRI , 2010, Magnetic resonance in medicine.

[15]  Mark W. Woolrich,et al.  Resting-state fMRI in the Human Connectome Project , 2013, NeuroImage.

[16]  Stephen M. Smith,et al.  Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging , 2010, PloS one.

[17]  Karl J. Friston,et al.  Unified segmentation , 2005, NeuroImage.

[18]  Steen Moeller,et al.  Pushing spatial and temporal resolution for functional and diffusion MRI in the Human Connectome Project , 2013, NeuroImage.

[19]  Karl J. Friston,et al.  Analysis of fMRI Time-Series Revisited , 1995, NeuroImage.

[20]  Stephen M. Smith,et al.  Effective artifact removal in resting state fMRI data improves detection of DMN functional connectivity alteration in Alzheimer's disease , 2015, Front. Hum. Neurosci..

[21]  Wen-Ming Luh,et al.  Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI , 2012, NeuroImage.

[22]  Martin Blaimer,et al.  General formulation for quantitative G‐factor calculation in GRAPPA reconstructions , 2009, Magnetic resonance in medicine.

[23]  Nikolaus Weiskopf,et al.  Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation , 2013, Front. Neurosci..

[24]  Essa Yacoub,et al.  Less noise, more activation: Multiband acquisition schemes for auditory functional MRI , 2015, Magnetic resonance in medicine.

[25]  Oliver Speck,et al.  The impact of physiological noise correction on fMRI at 7 T , 2011, NeuroImage.

[26]  Karl J. Friston,et al.  Classical and Bayesian Inference in Neuroimaging: Applications , 2002, NeuroImage.

[27]  Valentin Riedl,et al.  Evaluation of Multiband EPI Acquisitions for Resting State fMRI , 2015, PloS one.

[28]  Steen Moeller,et al.  Evaluation of highly accelerated simultaneous multi-slice EPI for fMRI , 2015, NeuroImage.

[29]  Ludovica Griffanti,et al.  Automatic denoising of functional MRI data: Combining independent component analysis and hierarchical fusion of classifiers , 2014, NeuroImage.

[30]  Peter J. Koopmans,et al.  Improved sensitivity and specificity for resting state and task fMRI with multiband multi-echo EPI compared to multi-echo EPI at 7T , 2015, NeuroImage.

[31]  Karl J. Friston,et al.  Analysis of fMRI Time-Series Revisited—Again , 1995, NeuroImage.

[32]  Steen Moeller,et al.  Evaluation of slice accelerations using multiband echo planar imaging at 3T , 2013, NeuroImage.

[33]  J. Finsterbusch,et al.  Optimization and Validation of Methods for Mapping of the Radiofrequency Transmit Field at 3T , 2010, Magnetic resonance in medicine.