Trabecular bone anisotropy imaging with a compact laser-undulator synchrotron x-ray source

Conventional x-ray radiography is a well-established standard in diagnostic imaging of human bones. It reveals typical bony anatomy with a strong surrounding cortical bone and trabecular structure of the inner part. However, due to limited spatial resolution, x-ray radiography cannot provide information on the microstructure of the trabecular bone. Thus, microfractures without dislocation are often missed in initial radiographs, resulting in a lack or delay of adequate therapy. Here we show that x-ray vector radiography (XVR) can overcome this limitation and allows for a deeper insight into the microstructure with a radiation exposure comparable to standard radiography. XVR senses x-ray ultrasmall-angle scattering in addition to the attenuation contrast and thereby reveals the mean scattering strength, its degree of anisotropy and the orientation of scattering structures. Corresponding to the structural characteristics of bones, there is a homogenous mean scattering signal of the trabecular bone but the degree of anisotropy is strongly affected by variations in the trabecular structure providing more detailed information on the bone microstructure. The measurements were performed at the Munich Compact Light Source, a novel type of x-ray source based on inverse Compton scattering. This laboratory-sized source produces highly brilliant quasi-monochromatic x-rays with a tunable energy.

[1]  Franz Pfeiffer,et al.  X-ray Dark-Field Vector Radiography—A Novel Technique for Osteoporosis Imaging , 2015, Journal of computer assisted tomography.

[2]  W. Jark,et al.  On amplitude beam splitting of tender X-rays (2-8 keV photon energy) using conical diffraction from reflection gratings with laminar profile. , 2016, Journal of synchrotron radiation.

[3]  Torben H. Jensen,et al.  Experimental validation of image contrast correlation between ultra-small-angle X-ray scattering and grating-based dark-field imaging using a laser-driven compact X-ray source , 2012 .

[4]  O. Bunk,et al.  Hard x-ray phase tomography with low-brilliance sources. , 2007, Physical review letters.

[5]  H. Wen,et al.  A Universal Moiré Effect and Application in X-Ray Phase-Contrast Imaging , 2016, Nature Physics.

[6]  Susan Standring PhD DSc Gray's Anatomy: The Anatomical Basis of Clinical Practice , 2005 .

[7]  Franz Pfeiffer,et al.  The Munich Compact Light Source: initial performance measures. , 2016, Journal of synchrotron radiation.

[8]  J. Nunley,et al.  Occult carpal pathology: tomographic evaluation , 2004, Skeletal Radiology.

[9]  Han Wen,et al.  A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging. , 2010, Medical physics.

[10]  A. Momose,et al.  Phase-contrast radiographs of nonstained rat cerebellar specimen. , 1995, Medical physics.

[11]  C-Y Chang,et al.  Systematic analysis of missed extremity fractures in emergency radiology , 2006, Acta radiologica.

[12]  Ashley F. Stein,et al.  Single-shot x-ray differential phase-contrast and diffraction imaging using two-dimensional transmission gratings. , 2010, Optics letters.

[13]  Marco Stampanoni,et al.  Human hand radiography using X-ray differential phase contrast combined with dark-field imaging , 2013, Skeletal Radiology.

[14]  F. Pfeiffer,et al.  Prediction of vertebral failure load by using x-ray vector radiographic imaging. , 2015, Radiology.

[15]  Timm Weitkamp,et al.  X-ray vector radiography for bone micro-architecture diagnostics , 2012, Physics in medicine and biology.

[16]  Atsushi Momose,et al.  Cadaveric and in vivo human joint imaging based on differential phase contrast by X-ray Talbot-Lau interferometry. , 2013, Zeitschrift fur medizinische Physik.

[17]  Franz Pfeiffer,et al.  Hard X-ray phase-contrast imaging with the Compact Light Source based on inverse Compton X-rays. , 2009, Journal of synchrotron radiation.

[18]  Franz Pfeiffer,et al.  X-ray dark-field and phase-contrast imaging using a grating interferometer , 2009 .

[19]  Franz Pfeiffer,et al.  Emphysema diagnosis using X-ray dark-field imaging at a laser-driven compact synchrotron light source , 2012, Proceedings of the National Academy of Sciences.

[20]  William C. Barber,et al.  Energy resolved X-ray grating interferometry , 2013 .

[21]  Franz Pfeiffer,et al.  Multimodal hard X-ray imaging of a mammography phantom at a compact synchrotron light source. , 2012, Journal of synchrotron radiation.

[22]  Haroon Rehman,et al.  Imaging of occult hip fractures: CT or MRI? , 2016, Injury.

[23]  P. Manske Fracture Of The Hook Of The Hamate Presenting As Carpal Tunnel Syndrome , 1978, The Hand.

[24]  Franz Pfeiffer,et al.  Toward Clinically Compatible Phase-Contrast Mammography , 2015, PloS one.

[25]  M. Strobl General solution for quantitative dark-field contrast imaging with grating interferometers , 2014, Scientific reports.

[26]  Franz Pfeiffer,et al.  Coherent Superposition in Grating-Based Directional Dark-Field Imaging , 2013, PloS one.

[27]  Franz Pfeiffer,et al.  Directional x-ray dark-field imaging of strongly ordered systems , 2010 .

[28]  R. Ruth,et al.  X-ray phase-contrast tomography with a compact laser-driven synchrotron source , 2015, Proceedings of the National Academy of Sciences.

[29]  S. Standring Gray's Anatomy: The Anatomical Basis of Clinical Practice , 2015 .

[30]  G. Potdevin,et al.  Monochromatic computed tomography with a compact laser-driven X-ray source , 2013, Scientific Reports.

[31]  Han Wen,et al.  Enhancing Tabletop X-Ray Phase Contrast Imaging with Nano-Fabrication , 2015, Scientific reports.

[32]  Franz Pfeiffer,et al.  Correlation of X-Ray Vector Radiography to Bone Micro-Architecture , 2014, Scientific Reports.

[33]  Han Wen,et al.  Subnanoradian X-ray phase-contrast imaging using a far-field interferometer of nanometric phase gratings , 2013, Nature Communications.

[34]  R. Ruth,et al.  Laser-Electron Storage Ring , 1998 .

[35]  B. Schmitt,et al.  Single shot x-ray phase contrast imaging using a direct conversion microstrip detector with single photon sensitivity , 2016 .

[36]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[37]  Catherine Yoon,et al.  Missed and delayed diagnoses in the emergency department: a study of closed malpractice claims from 4 liability insurers. , 2007, Annals of emergency medicine.

[38]  Pascal Meyer,et al.  On the origin and nature of the grating interferometric dark-field contrast obtained with low-brilliance x-ray sources , 2016, Physics in medicine and biology.

[39]  Franz Pfeiffer,et al.  Directional x-ray dark-field imaging , 2010, Physics in medicine and biology.