Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT

BackgroundAlthough single photon emission computed tomography (SPECT) and positron emission tomography (PET) myocardial perfusion imaging (MPI) have evolved considerably over the last decade, there is no recent comparison of diagnostic performance. This study was designed to assess relative image quality, interpretive confidence, and diagnostic accuracy by use of contemporary technology and protocols.Methods and ResultsBy consensus and without clinical information, 4 experienced nuclear cardiologists interpreted 112 SPECT technetium-99m sestamibi and 112 PET rubidium-82 MPI electrocardiography (ECG)-gated rest/pharmacologic stress studies in patient populations matched by gender, body mass index, and presence and extent of coronary disease. The patients were categorized as having a low likelihood for coronary artery disease (27 in each group) or had coronary angiography within 60 days. SPECT scans were acquired on a Cardio-60 system and PET scans on an ECAT ACCEL scanner. Image quality was excellent for 78% and 79% of rest and stress PET scans, respectively, versus 62% and 62% of respective SPECT scans (both p < .05). An equal percent of PET and SPECT gated images were rated excellent in quality. Interpretations were definitely normal or abnormal for 96% of PET scans versus 81% of SPECT scans (p = .001). Diagnostic accuracy was higher for PET for both stenosis severity thresholds of 70% (89% vs 79%,p = .03) and 50% (87% vs 71%,p = .003) and was higher in men and women, in obese and nonobese patients, and for correct identification of multivessel coronary artery disease.ConclusionIn a large population of matched pharmacologic stress patients, myocardial perfusion PET was superior to SPECT in image quality, interpretive certainty, and diagnostic accuracy.

[1]  J. E. Hansen,et al.  Updated imaging guidelines for nuclear cardiology procedures, part 1. , 2001, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[2]  R. Hendel,et al.  Impact of an abbreviated adenosine protocol incorporating adjunctive treadmill exercise on adverse effects and image quality in patients undergoing stress myocardial perfusion imaging , 2000, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[3]  R. Taillefer,et al.  Comparison between dipyridamole and adenosine as pharmacologic coronary vasodilators in detection of coronary artery disease with thallium 201 imaging , 1996, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[4]  P Suetens,et al.  A study of the liver-heart artifact in emission tomography. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  M. G. Levine,et al.  Comparison of exercise, dipyridamole, adenosine, and dobutamine stress with the use of Tc-99m tetrofosmin tomographic imaging , 1999, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[6]  M Schwaiger,et al.  Myocardial perfusion imaging with PET. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  W. Smith,et al.  Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging. , 1997, Journal of the American College of Cardiology.

[8]  T. Bateman Cardiac positron emission tomography and the role of adenosine pharmacologic stress. , 2004, The American journal of cardiology.

[9]  G. Thomas,et al.  Treadmill exercise during adenosine infusion is safe, results in fewer adverse reactions, and improves myocardial perfusion image quality , 2000, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[10]  M. Cerqueira,et al.  Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association , 2002, The international journal of cardiovascular imaging.

[11]  Daniel S. Berman,et al.  Cardiac SPECT imaging , 1994, Cardiovascular Drugs and Therapy.

[12]  R. Hendel,et al.  The value and practice of attenuation correction for myocardial perfusion SPECT imaging: a joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine. , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[13]  Y. Yonekura,et al.  Value and limitation of stress thallium-201 single photon emission computed tomography: comparison with nitrogen-13 ammonia positron tomography. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  E. Depuey,et al.  Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. , 1997, Journal of the American College of Cardiology.

[15]  D E Kuhl,et al.  Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease. , 1991, The American journal of cardiology.

[16]  F. Bengel,et al.  Attenuation Correction in Myocardial Perfusion SPECT/CT: Effects of Misregistration and Value of Reregistration , 2007, Journal of Nuclear Medicine.

[17]  M. Graffar [Modern epidemiology]. , 1971, Bruxelles medical.

[18]  J. Case,et al.  Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[19]  T. Marwick,et al.  Myocardial perfusion imaging with positron emission tomography and single photon emission computed tomography: frequency and causes of disparate results. , 1991, European heart journal.

[20]  K. Lance Gould,et al.  Clinical cardiac PET using generator-produced Rb-82: A review , 1989, CardioVascular and Interventional Radiology.

[21]  W. Smith,et al.  Comparison between 201Tl and 99mTc sestamibi uptake during adenosine-induced vasodilation as a function of coronary stenosis severity. , 1995, Circulation.

[22]  E. Antman,et al.  ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionucl , 2003, Journal of the American College of Cardiology.

[23]  R. Hendel,et al.  Impact of limited treadmill exercise on adenosine Tc-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging in coronary artery disease. , 1999, The American journal of cardiology.

[24]  R. Hendel,et al.  American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: Attenuation correction of myocardial perfusion SPECT scintigraphy , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[25]  G V Heller,et al.  Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging. , 1999, Circulation.

[26]  T. Bateman,et al.  Attenuation correction single-photon emission computed tomography myocardial perfusion imaging. , 2005, Seminars in nuclear medicine.

[27]  Bernice W. Polemis Nonparametric Statistics for the Behavioral Sciences , 1959 .

[28]  D. Pennell,et al.  A comparison of three radionuclide myocardial perfusion tracers in clinical practice: the ROBUST study , 2002, European Journal of Nuclear Medicine and Molecular Imaging.

[29]  Jonathan M. Links,et al.  Attenuation correction and gating synergistically improve the diagnostic accuracy of myocardial perfusion SPECT , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[30]  N. Mullani,et al.  A retrospective study of the diagnostic accuracy of a community hospital-based PET center for the detection of coronary artery disease using rubidium-82. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[31]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[32]  Josef Machac,et al.  Cardiac positron emission tomography imaging. , 2005, Seminars in nuclear medicine.

[33]  W J MacIntyre,et al.  A prospective comparison of rubidium-82 PET and thallium-201 SPECT myocardial perfusion imaging utilizing a single dipyridamole stress in the diagnosis of coronary artery disease. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[34]  D. Pennell,et al.  Adenosine combined with dynamic exercise for myocardial perfusion imaging. , 1995, Journal of the American College of Cardiology.

[35]  E. Depuey,et al.  Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.