Four-dimensional cone-beam computed tomography using an on-board imager.

On-board cone-beam computed tomography (CBCT) has recently become available to provide volumetric information of a patient in the treatment position, and holds promises for improved target localization and irradiation dose verification. The design of currently available on-board CBCT, however, is far from optimal. Its quality is adversely influenced by many factors, such as scatter, beam hardening, and intra-scanning organ motion. In this work we quantitatively study the influence of organ motion on CBCT imaging and investigate a strategy to acquire high quality phase-resolved [four-dimensional (4D)] CBCT images based on phase binning of the CBCT projection data. An efficient and robust method for binning CBCT data according to the patient's respiratory phase derived in the projection space was developed. The phase-binned projections were reconstructed using the conventional Feldkamp algorithm to yield 4D CBCT images. Both phantom and patient studies were carried out to validate the technique and to optimize the 4D CBCT data acquisition protocol. Several factors that are important to the clinical implementation of the technique, such as the image quality, scanning time, number of projections, and radiation dose, were analyzed for various scanning schemes. The general references drawn from this study are: (i) reliable phase binning of CBCT projections is accomplishable with the aid of external or internal marker and simple analysis of its trace in the projection space, and (ii) artifact-free 4D CBCT images can be obtained without increasing the patient radiation dose as compared to the current 3D CBCT scan.

[1]  D. DeRosier,et al.  The reconstruction of a three-dimensional structure from projections and its application to electron microscopy , 1970, Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences.

[2]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[3]  C. J. Ritchie,et al.  Predictive respiratory gating: a new method to reduce motion artifacts on CT scans. , 1994, Radiology.

[4]  Cameron J. Ritchie,et al.  Respiratory compensation in projection imaging using a magnification and displacement model , 1996, IEEE Trans. Medical Imaging.

[5]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[6]  Weiguo Lu,et al.  Tomographic motion detection and correction directly in sinogram space. , 2002, Physics in medicine and biology.

[7]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[8]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[9]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[10]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[11]  Jean-Philippe Pignol,et al.  Correlation of lung tumor motion with external surrogate indicators of respiration. , 2004, International journal of radiation oncology, biology, physics.

[12]  George Starkschall,et al.  Evaluation of internal lung motion for respiratory-gated radiotherapy using MRI: Part I--correlating internal lung motion with skin fiducial motion. , 2004, International journal of radiation oncology, biology, physics.

[13]  Gregory C Sharp,et al.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors. , 2004, Physics in medicine and biology.

[14]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[15]  M. V. van Herk,et al.  Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI). , 2005, International journal of radiation oncology, biology, physics.

[16]  Eduard Schreibmann,et al.  Mapping Electron Density Distribution from Planning CT to Cone-Beam CT (CBCT): a Novel Strategy for Accurate Dose Calculation Based on CBCT , 2005 .

[17]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[18]  G H Olivera,et al.  The use of megavoltage CT (MVCT) images for dose recomputations , 2005, Physics in medicine and biology.

[19]  John Wong,et al.  Assessment of residual error for online cone-beam CT-guided treatment of prostate cancer patients. , 2004, International journal of radiation oncology, biology, physics.

[20]  Patrick A Kupelian,et al.  Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit. , 2005, Medical physics.

[21]  A. Boyer,et al.  Radiation dose reduction in four-dimensional computed tomography. , 2005, Medical physics.

[22]  Ping Xia,et al.  Low-dose megavoltage cone-beam CT for radiation therapy. , 2005, International journal of radiation oncology, biology, physics.

[23]  Mark Oldham,et al.  Cone-beam-CT guided radiation therapy: A model for on-line application. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  He Wang,et al.  Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes. , 2005, International journal of radiation oncology, biology, physics.

[25]  David A. Jaffray,et al.  Towards a One-Step Scan and Treat Process for Palliative Radiotherapy - a Potential Application for Cone Beam Computerized Tomography (CBCT) , 2005 .

[26]  L Xing,et al.  Motion correction for improved target localization with on-board cone-beam computed tomography , 2006, Physics in medicine and biology.

[27]  L. Xing,et al.  Overview of image-guided radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[28]  George Starkschall,et al.  Displacement-based binning of time-dependent computed tomography image data sets. , 2006, Medical physics.

[29]  Uwe Oelfke,et al.  Linac-integrated 4D cone beam CT: first experimental results , 2006, Physics in medicine and biology.

[30]  Lei Xing,et al.  Evaluation of on-board kV cone beam CT (CBCT)-based dose calculation , 2007, Physics in medicine and biology.