An adaptive gyroscope-based algorithm for temporal gait analysis

Body-worn kinematic sensors have been widely proposed as the optimal solution for portable, low cost, ambulatory monitoring of gait. This study aims to evaluate an adaptive gyroscope-based algorithm for automated temporal gait analysis using body-worn wireless gyroscopes. Gyroscope data from nine healthy adult subjects performing four walks at four different speeds were then compared against data acquired simultaneously using two force plates and an optical motion capture system. Data from a poliomyelitis patient, exhibiting pathological gait walking with and without the aid of a crutch, were also compared to the force plate. Results show that the mean true error between the adaptive gyroscope algorithm and force plate was −4.5 ± 14.4 ms and 43.4 ± 6.0 ms for IC and TC points, respectively, in healthy subjects. Similarly, the mean true error when data from the polio patient were compared against the force plate was −75.61 ± 27.53 ms and 99.20 ± 46.00 ms for IC and TC points, respectively. A comparison of the present algorithm against temporal gait parameters derived from an optical motion analysis system showed good agreement for nine healthy subjects at four speeds. These results show that the algorithm reported here could constitute the basis of a robust, portable, low-cost system for ambulatory monitoring of gait.

[1]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[2]  Marco Parvis,et al.  Procedure for effortless in-field calibration of three-axial rate gyro and accelerometers , 1995 .

[3]  Jeffrey M. Hausdorff,et al.  Altered fractal dynamics of gait: reduced stride-interval correlations with aging and Huntington's disease. , 1997, Journal of applied physiology.

[4]  M H Granat,et al.  A practical gait analysis system using gyroscopes. , 1999, Medical engineering & physics.

[5]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[6]  R N Marshall,et al.  Algorithms to determine event timing during normal walking using kinematic data. , 2000, Journal of biomechanics.

[7]  Kamiar Aminian,et al.  Measurement of stand-sit and sit-stand transitions using a miniature gyroscope and its application in fall risk evaluation in the elderly , 2002, IEEE Transactions on Biomedical Engineering.

[8]  Kamiar Aminian,et al.  Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes. , 2002, Journal of biomechanics.

[9]  W. Art Chaovalitwongse,et al.  Adaptive epileptic seizure prediction system , 2003, IEEE Transactions on Biomedical Engineering.

[10]  A. Hof,et al.  Assessment of spatio-temporal gait parameters from trunk accelerations during human walking. , 2003, Gait & posture.

[11]  K. Aminian,et al.  Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement. , 2004, Gait & posture.

[12]  Catherine Dehollain,et al.  Gait assessment in Parkinson's disease: toward an ambulatory system for long-term monitoring , 2004, IEEE Transactions on Biomedical Engineering.

[13]  Angelo M. Sabatini,et al.  Assessment of walking features from foot inertial sensing , 2005, IEEE Transactions on Biomedical Engineering.

[14]  Jeffrey M. Hausdorff,et al.  Effect of gait speed on gait rhythmicity in Parkinson's disease: variability of stride time and swing time respond differently , 2005, Journal of NeuroEngineering and Rehabilitation.

[15]  R. Rangayyan,et al.  Biomedical Signal Analysis , 2015 .

[16]  J. Allum,et al.  Gait event detection using linear accelerometers or angular velocity transducers in able-bodied and spinal-cord injured individuals. , 2006, Gait & posture.

[17]  Philip de Chazal,et al.  A Patient-Adapting Heartbeat Classifier Using ECG Morphology and Heartbeat Interval Features , 2006, IEEE Transactions on Biomedical Engineering.

[18]  Ciara M O'Connor,et al.  Automatic detection of gait events using kinematic data. , 2007, Gait & posture.

[19]  P. Bonato,et al.  Wearable Wireless Sensor Network to Assess Clinical Status in Patients with Neurological Disorders , 2007, 2007 6th International Symposium on Information Processing in Sensor Networks.

[20]  Paola Catalfamo,et al.  Detection of gait events using an F-Scan in-shoe pressure measurement system. , 2008, Gait & posture.

[21]  Kwang Suk Park,et al.  Adaptive windowing for gait phase discrimination in Parkinsonian gait using 3-axis acceleration signals , 2009, Medical & Biological Engineering & Computing.

[22]  Adriano Ferrari,et al.  ‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors , 2009, Medical & Biological Engineering & Computing.

[23]  Adam Miller,et al.  Gait event detection using a multilayer neural network. , 2009, Gait & posture.

[24]  Brian Caulfield,et al.  SHIMMER: A new tool for temporal gait analysis , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Adrian Burns,et al.  SHIMMER™ – A Wireless Sensor Platform for Noninvasive Biomedical Research , 2010, IEEE Sensors Journal.

[26]  D Kotiadis,et al.  Inertial Gait Phase Detection for control of a drop foot stimulator Inertial sensing for gait phase detection. , 2010, Medical engineering & physics.