An investigation into the flexural characteristics of functionally graded cobalt chrome femoral stems manufactured using selective laser melting

In order to reduce the stress shielding of the femur following Total Hip Arthroplasty (THA), stiffness matching strategies between the host bone and femoral stem still need to be investigated. Additive Layer Manufacturing (ALM) technologies such as Selective Laser Melting (SLM) can produce components from a single alloy with varying mechanical properties, and hence, functionally graded parts. This work considers the flexural characteristics of laser melted cobalt chrome femoral stems, by using a combination of mechanical testing and finite element analysis. A functionally graded design methodology was considered in order to reduce the weight and stiffness of the femoral stems. Three separate functionally graded designs were investigated by incorporating square pore cellular structures of varying density. The results confirmed that selective laser melting can repeatedly manufacture a functionally graded femoral stem that is 48% lighter and 60% more flexible than a traditional fully dense stem. However, there are concerns associated with the repeatability of the manufacturing process for producing stems with cellular structures that incorporate strut sizes, which are equal to or less than 0.5 mm.

[1]  Yang Hao,et al.  Compression fatigue behavior of Ti-6Al-4V mesh arrays fabricated by electron beam melting , 2012 .

[2]  O. Harrysson,et al.  Direct metal fabrication of titanium implants with tailored materials and mechanical properties using electron beam melting technology , 2008 .

[3]  G. Lyritis,et al.  The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: a 10-year, prospective, randomized study. , 2004, The Journal of arthroplasty.

[4]  Fábio Pinto da Silva,et al.  Medical design: Direct metal laser sintering of Ti–6Al–4V , 2010 .

[5]  Mark Stanford,et al.  Evaluation of the stiffness characteristics of square pore CoCrMo cellular structures manufactured using laser melting technology for potential orthopaedic applications , 2013 .

[6]  S. Raman,et al.  A design for the additive manufacture of functionally graded porous structures with tailored mechanical properties for biomedical applications , 2011 .

[7]  L. Murr,et al.  Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays , 2010, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[8]  Carlo Kopp Electro-Optical Systems , 1984 .

[9]  Hans Jürgen Maier,et al.  Additively manufactured cellular structures: Impact of microstructure and local strains on the monotonic and cyclic behavior under uniaxial and bending load , 2013 .

[10]  Sergio Rivera,et al.  DEVELOPMENT OF DENSE AND CELLULAR SOLIDS IN CRCOMO ALLOY FOR ORTHOPAEDIC APPLICATIONS , 2011 .

[11]  Mikhail Rabinovich,et al.  Biomechanical properties of an intact, injured, repaired, and healed femur: an experimental and computational study. , 2012, Journal of the mechanical behavior of biomedical materials.

[12]  José A. Simões,et al.  Design of a composite hip femoral prosthesis , 2005 .

[13]  L. Whiteside,et al.  The effect of stem fit on bone hypertrophy and pain relief in cementless total hip arthroplasty. , 1989, Clinical orthopaedics and related research.

[14]  Ola L. A. Harrysson,et al.  Properties of Ti–6Al–4V non-stochastic lattice structures fabricated via electron beam melting , 2008 .

[15]  J. Gelin,et al.  Composite based on polyetheretherketone reinforced with carbon fibres, an alternative to conventional materials for femoral implant: Manufacturing process and resulting structural behaviour , 2012 .

[16]  T. J. Joyce,et al.  Taper junction failure in large-diameter metal-on-metal bearings , 2012, Bone & joint research.