Time-lapse electrical impedance spectroscopy for monitoring the cell cycle of single immobilized S. pombe cells

As a complement and alternative to optical methods, wide-band electrical impedance spectroscopy (EIS) enables multi-parameter, label-free and real-time detection of cellular and subcellular features. We report on a microfluidics-based system designed to reliably capture single rod-shaped Schizosaccharomyces pombe cells by applying suction through orifices in a channel wall. The system enables subsequent culturing of immobilized cells in an upright position, while dynamic changes in cell-cycle state and morphology were continuously monitored through EIS over a broad frequency range. Besides measuring cell growth, clear impedance signals for nuclear division have been obtained. The EIS system has been characterized with respect to sensitivity and detection limits. The spatial resolution in measuring cell length was 0.25 μm, which corresponds to approximately a 5-min interval of cell growth under standard conditions. The comprehensive impedance data sets were also used to determine the occurrence of nuclear division and cytokinesis. The obtained results have been validated through concurrent confocal imaging and plausibilized through comparison with finite-element modeling data. The possibility to monitor cellular and intracellular features of single S. pombe cells during the cell cycle at high spatiotemporal resolution renders the presented microfluidics-based EIS system a suitable tool for dynamic single-cell investigations.

[1]  R. Zare,et al.  Microfluidic platforms for single-cell analysis. , 2010, Annual review of biomedical engineering.

[2]  Charlotte Schubert,et al.  Single-cell analysis: The deepest differences , 2011, Nature.

[3]  D. Marshall,et al.  Microfluidics for single cell analysis. , 2012, Current opinion in biotechnology.

[4]  Fabian Rudolf,et al.  Microfluidic single-cell cultivation chip with controllable immobilization and selective release of yeast cells. , 2012, Lab on a chip.

[5]  P. Fantes Control of cell size and cycle time in Schizosaccharomyces pombe. , 1977, Journal of cell science.

[6]  S. Gawad,et al.  Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing. , 2001, Lab on a chip.

[7]  Min Cheol Park,et al.  High-throughput single-cell quantification using simple microwell-based cell docking and programmable time-course live-cell imaging. , 2011, Lab on a chip.

[8]  Andreas Hierlemann,et al.  Characterization of subcellular morphology of single yeast cells using high frequency microfluidic impedance cytometer. , 2014, Lab on a chip.

[9]  J. Skotheim,et al.  Cell Size Control in Yeast , 2012, Current Biology.

[10]  Paul Nurse,et al.  Genetic control of cell size at cell division in yeast , 1975, Nature.

[11]  A. Marble,et al.  Impedance spectroscopy: An accurate method of differentiating between viable and ischaemic or infarcted muscle tissue , 2002, Medical and Biological Engineering and Computing.

[12]  C. chou,et al.  Is green fluorescent protein toxic to the living cells? , 1999, Biochemical and biophysical research communications.

[13]  Xin Zhang,et al.  Real-time monitoring primary cardiomyocyte adhesion based on electrochemical impedance spectroscopy and electrical cell-substrate impedance sensing. , 2008, Analytical chemistry.

[14]  John J. Tyson,et al.  Modeling the fission yeast cell cycle : Quantized cycle times in wee 1 2 cdc 25 D mutant cells , 2000 .

[15]  S. Gawad,et al.  Single cell dielectric spectroscopy , 2007 .

[16]  S. Bodovitz,et al.  Single cell analysis: the new frontier in 'omics'. , 2010, Trends in biotechnology.

[17]  Hywel Morgan,et al.  Continuous differential impedance spectroscopy of single cells , 2009, Microfluidics and nanofluidics.

[18]  Hywel Morgan,et al.  Single-cell microfluidic impedance cytometry: a review , 2010 .

[19]  Robert C. Wolpert,et al.  A Review of the , 1985 .

[20]  Junjie Li,et al.  Single cell optical imaging and spectroscopy. , 2013, Chemical reviews.

[21]  Dino Di Carlo,et al.  Dynamic single-cell analysis for quantitative biology. , 2006, Analytical chemistry.

[22]  Yu Sun,et al.  High-throughput biophysical measurement of human red blood cells. , 2012, Lab on a chip.

[23]  B. Novák,et al.  The size control of fission yeast revisited. , 1996, Journal of cell science.

[24]  Pierre O. Bagnaninchi,et al.  Real-time label-free monitoring of adipose-derived stem cell differentiation with electric cell-substrate impedance sensing , 2011, Proceedings of the National Academy of Sciences.

[25]  Jian Xu,et al.  Single-cell bioelectrical impedance platform for monitoring cellular response to drug treatment , 2011, Physical biology.

[26]  P. Nurse,et al.  Growth in cell length in the fission yeast Schizosaccharomyces pombe. , 1985, Journal of cell science.

[27]  Kwang-Seok Yun,et al.  Single-cell manipulation on microfluidic chip by dielectrophoretic actuation and impedance detection , 2010 .

[28]  Luke P. Lee,et al.  Dynamic single cell culture array. , 2006, Lab on a chip.

[29]  Matsuhiko Nishizawa,et al.  Monitoring impedance changes associated with motility and mitosis of a single cell. , 2010, Lab on a chip.

[30]  Klaus Eyer,et al.  A microchamber array for single cell isolation and analysis of intracellular biomolecules. , 2012, Lab on a chip.

[31]  A. van den Berg,et al.  Gene transfer and protein dynamics in stem cells using single cell electroporation in a microfluidic device. , 2008, Lab on a chip.

[32]  A. Folch,et al.  Large-scale single-cell trapping and imaging using microwell arrays. , 2005, Analytical chemistry.

[33]  Jun Zhou,et al.  Cytotoxicity of red fluorescent protein DsRed is associated with the suppression of Bcl‐xL translation , 2011, FEBS letters.

[34]  Ellen C. Jensen* Use of Fluorescent Probes: Their Effect on Cell Biology and Limitations , 2012, Anatomical record.

[35]  Ling-Sheng Jang,et al.  Integration of single-cell trapping and impedance measurement utilizing microwell electrodes. , 2011, Biosensors & bioelectronics.

[36]  David K. Wood,et al.  Single cell trapping and DNA damage analysis using microwell arrays , 2010, Proceedings of the National Academy of Sciences.

[37]  B G Schutt The promise in practice. , 1967, The American journal of nursing.

[38]  J. Tyson,et al.  Modeling the fission yeast cell cycle: quantized cycle times in wee1- cdc25Delta mutant cells. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[39]  H. Morgan,et al.  Microfluidic lysis of human blood for leukocyte analysis using single cell impedance cytometry. , 2012, Analytical chemistry.

[40]  C. Hansen,et al.  Microfluidic single cell analysis: from promise to practice. , 2012, Current opinion in chemical biology.

[41]  Andreas Hierlemann,et al.  Real-time monitoring of immobilized single yeast cells through multifrequency electrical impedance spectroscopy , 2014, Analytical and Bioanalytical Chemistry.

[42]  Urban Seger,et al.  Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations. , 2004, Lab on a chip.

[43]  Andrew G. Glen,et al.  APPL , 2001 .

[44]  Peter Wiktor,et al.  Single cells and intracellular processes studied by a plasmonic-based electrochemical impedance microscopy. , 2011, Nature chemistry.

[45]  Jaehoon Chung,et al.  Highly-efficient single-cell capture in microfluidic array chips using differential hydrodynamic guiding structures. , 2011, Applied physics letters.

[46]  Tien Anh Nguyen,et al.  Microfluidic chip with integrated electrical cell-impedance sensing for monitoring single cancer cell migration in three-dimensional matrixes. , 2013, Analytical chemistry.

[47]  L. Strukova,et al.  A monomeric red fluorescent protein with low cytotoxicity , 2012, Nature Communications.

[48]  Mary L. Bouxsein,et al.  Theoretical and Practical Considerations , 2001 .

[49]  I. Tolic-Nørrelykke,et al.  Growth pattern of single fission yeast cells is bilinear and depends on temperature and DNA synthesis. , 2009, Biophysical journal.

[50]  Yi Wang,et al.  A microfluidic impedance flow cytometer for identification of differentiation state of stem cells. , 2013, Lab on a chip.

[51]  Sungjae Ha,et al.  Electric impedance microflow cytometry for characterization of cell disease states. , 2013, Lab on a chip.