Detection of sulfur in the reinforced concrete structures using a dual pulsed LIBS system

Abstract In concrete structures, an excessive amount of sulfate ions can cause severe damage to the strength and the stability of the building structures and hence a sensitive and reliable technique for sulfate ion detection in concrete is highly desirable. Laser-induced breakdown spectroscopy (LIBS) is one of the most reliable and sensitive techniques to identify the presence of potentially dangerous sulfur in the concrete structure. The atomic emission lines of sulfur lying in the 200–900 nm region are mostly singly ionized states and hence inherently very weak. In order to enhance the sensitivity of the conventional LIBS system, we employed a dual pulsed LIBS system for detection of weak spectral line of sulfur in concrete using the S II peak at 545.38 nm as a marker for quantifying sulfur content in the concrete. The 1064 nm fundamental and 266 nm fourth harmonic of the Nd:YAG laser in conjunction with Spectrograph/gated ICCD camera are the core factors in improvement of sensitivity. Furthermore, the dual pulsed LIBS system and the fine maneuvering of the gate parameters and interpulse delay yielded improvement in the sensitivity, and resulted in a systematic correlation of the LIBS signal with the concentration of sulfur in the concrete sample. In order to quantify the sulfur content in concrete, a calibration curve was also drawn by recording the LIBS spectra of sample having sulfur in various concentrations. The limit of detection achieved with our dual pulsed LIBS system is approximately 38 μg/g.

[1]  R. Wiens,et al.  Laser-Induced Breakdown Spectroscopy for Mars surface analysis: capabilities at stand-off distances and detection of chlorine and sulfur elements , 2004 .

[2]  Zulfiqar Ahmed,et al.  Detection of contaminants in ore samples using laser-induced breakdown spectroscopy , 2007, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.

[3]  Harvey H. Haynes,et al.  Concrete Deterioration From Phusical Attack By Salts , 1996 .

[4]  Z. Yamani,et al.  Detection of heavy metals in Arabian crude oil residue using laser induced breakdown spectroscopy. , 2006, Talanta.

[5]  J. Javier Laserna,et al.  Laser-induced plasma spectrometry: truly a surface analytical tool , 2004 .

[6]  G. Galbács,et al.  Multi-pulse laser-induced plasma spectroscopy using a single laser source and a compact spectrometer , 2005 .

[7]  R. Noll,et al.  Laser-induced breakdown spectrometry — applications for production control and quality assurance in the steel industry , 2001 .

[8]  Stewart Clegg,et al.  Strategies for Mars remote Laser-Induced Breakdown Spectroscopy analysis of sulfur in geological samples , 2011 .

[9]  G. Asimellis,et al.  New near-infrared LIBS detection technique for sulfur , 2006, Analytical and bioanalytical chemistry.

[10]  J. D. Winefordner,et al.  Variables Influencing the Precision of Laser-Induced Breakdown Spectroscopy Measurements , 1998 .

[11]  Z. Yamani,et al.  The role of various binding materials for trace elemental analysis of powder samples using laser-induced breakdown spectroscopy. , 2007, Talanta.

[12]  F. Colao,et al.  Laser ablation of copper based alloys by single and double pulse laser induced breakdown spectroscopy , 2006 .

[13]  W. C. Martin,et al.  Atomic Spectra Database , 1999 .

[14]  S. Angel,et al.  Dual-Pulse LIBS Using a Pre-Ablation Spark for Enhanced Ablation and Emission , 2000 .

[15]  F. Weritz,et al.  Detailed depth profiles of sulfate ingress into concrete measured with laser induced breakdown spectroscopy , 2009 .

[16]  T. Zaremba,et al.  Properties of the wastes produced in the semi-dry FGD installation , 2008 .

[17]  M. Gondal,et al.  Monitoring and assessment of toxic metals in Gulf War oil spill contaminated soil using laser-induced breakdown spectroscopy , 2007, Environmental monitoring and assessment.

[18]  M. Gondal,et al.  Determination of poisonous metals in wastewater collected from paint manufacturing plant using laser-induced breakdown spectroscopy. , 2007, Talanta.

[19]  Heinz Falk,et al.  Application of vacuum ultraviolet laser-induced breakdown spectrometry for steel analysis — comparison with spark-optical emission spectrometry figures of merit , 2001 .

[20]  Z. Yamani,et al.  Study of hazardous metals in iron slag waste using laser induced breakdown spectroscopy , 2007, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.

[21]  F. Weritz,et al.  Quantitative determination of sulfur content in concrete with laser-induced breakdown spectroscopy ☆ , 2005 .

[22]  Stewart Clegg,et al.  Optimization of laser-induced breakdown spectroscopy for rapid geochemical analysis , 2010 .

[23]  M. Sabsabi,et al.  Enhanced laser-induced breakdown spectroscopy using the combination of fourth-harmonic and fundamental Nd:YAG laser pulses , 2002 .

[24]  Z. Yamani,et al.  Determination of trace elements in volcanic rock samples collected from cenozoic lava eruption sites using LIBS , 2009, Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering.

[25]  S. N. Isakov,et al.  Time-resolved spectroscopy and imaging diagnostics of single pulse and collinear double pulse laser induced plasma from a glass sample , 2008 .

[26]  Dietmar K. Schneider INCREASING PRODUCTION AND PROFITS WITH HOT CONCRETE , 1973 .

[27]  G. Wilsch,et al.  Laser-induced breakdown spectroscopy for on-line sulfur analyses of minerals in ambient conditions , 2009 .

[28]  J. Winefordner,et al.  Microchip laser ablation of metals: investigation of the ablation process in view of its application to laser-induced breakdown spectroscopy , 2005 .

[29]  S. Angel,et al.  Emission enhancement mechanisms in dual-pulse LIBS. , 2006, Analytical chemistry.

[30]  R. Russo,et al.  PrefaceFourth International Conference on Laser Induced Plasma Spectroscopy and Applications (LIBS 2006) , 2007 .

[31]  V. Lazic,et al.  A comparison of single and double pulse laser-induced breakdown spectroscopy of aluminum samples , 2002 .

[32]  Leon J. Radziemski,et al.  Handbook of Laser-Induced Breakdown Spectroscopy , 2006 .

[33]  Significance of pre-existing cracks on nucleation of secondary ettringite in steam cured cement paste , 1994 .

[34]  S. Michael Angel,et al.  Effect of Pulse Delay Time on a Pre-Ablation Dual-Pulse LIBS Plasma , 2001 .

[35]  Stefano Legnaioli,et al.  Spectroscopic and shadowgraphic analysis of laser induced plasmas in the orthogonal double pulse pre-ablation configuration , 2006 .

[36]  P. S. Banks,et al.  Double-pulse machining as a technique for the enhancement of material removal rates in laser machining of metals , 2005 .

[37]  Gerd Wilsch,et al.  Detector comparison for sulfur and chlorine detection with laser induced breakdown spectroscopy in the near-infrared-region ☆ , 2007 .

[38]  Israel Schechter,et al.  Laser-induced breakdown spectroscopy (LIBS) : fundamentals and applications , 2006 .

[39]  R. Niessner,et al.  Microanalysis by laser-induced plasma spectroscopy in the vacuum ultraviolet. , 2004, Analytical chemistry.

[40]  M. Gondal,et al.  Spectroscopic detection of health hazardous contaminants in lipstick using Laser Induced Breakdown Spectroscopy. , 2010, Journal of hazardous materials.

[41]  S. N. Isakov,et al.  Analysis of lead and sulfur in environmental samples by double pulse laser induced breakdown spectroscopy , 2009 .