Radiofrequency perforation of the pulmonary valve: an efficient low cost solution

Abstract Objective The aim of the study was to assess the feasibility of using commonly available catheterization laboratory equipment for radiofrequency perforation of the pulmonary valve in patients with pulmonary atresia and intact ventricular septum. Methods The system (off-label use for all items) is made up of a co-axial telescopic arrangement consisting of a 0.014" PT2 ™ coronary guidewire, for insulation inside a 2.7-F microcatheter which has an inner lumen of 0.021". The microcatheter was passed via a standard 4-F right coronary catheter to just below the atretic pulmonary valve. Radiofrequency (RF) energy was delivered using a standard electrosurgical system. In vitro testing had been performed and indicated that 5-10 W for 2-5 s would be sufficient for valve perforation. Results Radiofrequency perforation was successfully performed in all (n = 5, 100%) patients at a median age of 3 days (range: 1-36) and weight 2.7 kg (range 2.3-3.0). In one patient the pericardium was entered during the initial attempt; the generator was put on coagulation mode during retrieval of the guidewire and no haemopericardium occurred. The pulmonary valve was dilated in all; in three patients (n = 3) the ductus arteriosus was stented during the same session. Conclusion Results of the study show that it is feasible to perforate the pulmonary valve safely using this system. Availability, simplicity and cost are noteworthy benefits.

[1]  V. Konda,et al.  Electrosurgical generators. , 2013, Gastrointestinal endoscopy.

[2]  H. Samion,et al.  Pulmonary atresia with intact septum: the use of Conquest Pro coronary guidewire for perforation of atretic valve and subsequent interventions , 2012, Cardiology in the Young.

[3]  S. Qureshi,et al.  Long-term outcome following catheter valvotomy for pulmonary atresia with intact ventricular septum. , 2012, Journal of the American College of Cardiology.

[4]  F. Pinto,et al.  Percutaneous treatment of pulmonary atresia with intact ventricular septum: pulmonary valve perforation using radiofrequency energy and arterial duct stenting. , 2011, Revista Portuguesa de Cardiologia.

[5]  G. Pongiglione,et al.  Long-term results of catheter-based treatment of pulmonary atresia and intact ventricular septum , 2009, Heart.

[6]  S. Abadir,et al.  Transcatheter perforation followed by pulmonary valvuloplasty in neonates with pulmonary atresia and ventricular septal defect. , 2009, Archives of cardiovascular diseases.

[7]  B. Eyskens,et al.  Use of a microcatheter in a telescopic system to reach difficult targets in complex congenital heart disease , 2009, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[8]  L. Benson,et al.  Radiofrequency perforation of the right ventricular outflow tract as a palliative strategy for pulmonary atresia with ventricular septal defect , 2007, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[9]  P. Savard,et al.  Radio frequency perforation of cardiac tissue: Modelling and experimental results , 2000, Medical and Biological Engineering and Computing.

[10]  L. Benson,et al.  Radiofrequency applications in congenital heart disease , 2004, Expert review of cardiovascular therapy.

[11]  W. Williams,et al.  Percutaneous Balloon Valvotomy in Pulmonary Atresia With Intact Ventricular Septum: Impact on Patient Care , 2003, Circulation.

[12]  L. Benson,et al.  Radiofrequency perforation in the treatment of congenital heart disease , 2002, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[13]  Yih-Sharng Chen,et al.  Outcomes of transcatheter valvotomy in patients with pulmonary atresia and intact ventricular septum. , 1999, The American journal of cardiology.

[14]  I. Michel-Behnke,et al.  Transcatheter radiofrequency perforation and stent implantation for palliation of pulmonary atresia in a 3060-g infant. , 1995, Catheterization and cardiovascular diagnosis.

[15]  S. Qureshi,et al.  Radiofrequency-assisted balloon dilatation in patients with pulmonary valve atresia and an intact ventricular septum. , 1993, British heart journal.