Dipole source localization in the study of EP generators: a critique.

(1) The decision to solve the inverse problem in terms of one or more localized generators implies the assumption of a particular generator model. This assumption permits carrying out inverse dipole estimation. However, it is perilous to justify the procedure on the basis of the result. (2) Goodness of fit is a necessary but not sufficient criterion of model adequacy. A particular quantitative inverse solution has meaning only if it is accompanied by consideration of sensitivity to small changes in all of the free modeling parameters and estimates of perturbing factors including noise and forward calculation uncertainties.

[1]  J. P. Ary,et al.  Location of Sources of Evoked Scalp Potentials: Corrections for Skull and Scalp Thicknesses , 1981, IEEE Transactions on Biomedical Engineering.

[2]  C. C. Wood APPLICATION OF DIPOLE LOCALIZATION METHODS TO SOURCE IDENTIFICATION OF HUMAN EVOKED POTENTIALS * , 1980, Annals of the New York Academy of Sciences.

[3]  R D Sidman,et al.  A reliable method for localizing deep intracranial sources of the EEG , 1985, Neurology.

[4]  C C Wood,et al.  Electrical sources in human somatosensory cortex: identification by combined magnetic and potential recordings. , 1985, Science.

[5]  R D Sidman,et al.  A method for localization of sources of human cerebral potentials evoked by sensory stimuli. , 1978, Sensory processes.

[6]  Yoshiwo Okamoto,et al.  Limitation of the Inverse Problem in Body Surface Potential Mapping , 1983, IEEE Transactions on Biomedical Engineering.

[7]  F. Roberge,et al.  Moving Dipole Inverse ECG and EEG Solutions , 1984, IEEE Transactions on Biomedical Engineering.

[8]  H. Helmholtz Ueber einige Gesetze der Vertheilung elektrischer Ströme in körperlichen Leitern mit Anwendung auf die thierisch‐elektrischen Versuche , 1853 .

[9]  P. Nunez,et al.  The brain's magnetic field: some effects of multiple sources on localization methods. , 1986, Electroencephalography and clinical neurophysiology.

[10]  S. Butler,et al.  Cortical generators of the CI component of the pattern-onset visual evoked potential. , 1987, Electroencephalography and clinical neurophysiology.

[11]  U. Mitzdorf Current source-density method and application in cat cerebral cortex: investigation of evoked potentials and EEG phenomena. , 1985, Physiological reviews.

[12]  C. C. Wood,et al.  Task-dependent field potentials in human hippocampal formation , 1989, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[13]  M. Scherg,et al.  Evoked dipole source potentials of the human auditory cortex. , 1986, Electroencephalography and clinical neurophysiology.

[14]  D H Fender,et al.  Methods for the localization of electrical sources in the human brain. , 1980, Progress in brain research.