Harmonic Reduction in Variable Frequency Drives Using Active Power Filter

In this paper Voltage Source Inverter (VSI) is used to supply a variable frequency variable voltage to a three phase induction motor drive in a variable speed application. One important complication is that, Voltage Source Inverter (VSI) used in VFD causes non-sinusoidal output voltage and current due to presence of harmonics. Shunt active filter with VSI topology is proposed for current harmonic elimination. The current control scheme proposed for SAPF is Synchronous Reference Frame theory applied to SVPWM. The reference current can be calculated by using Reference Frame Transformation, reference current are transformed from a−b−c stationary frame to d−q rotating frame. In SVPWM technique, the Active Power Filter reference voltage is generated and desired Active Power Filter output voltage is generated by SVPWM. The analysis of simulation results are carried out in MATLAB/SIMULINK model.

[1]  H.A. Toliyat,et al.  A hybrid converter system for high-performance large induction motor drives , 2005, IEEE Transactions on Energy Conversion.

[2]  Manjari Mehrotra Harmonics Analysis of VSI Fed Induction Motor Drive , 2012 .

[3]  Nisha G. K. Harmonic Elimination of Space Vector Modulated Three Phase Inverter , 2012 .

[4]  Venu Gopala Rao Mannam,et al.  ANALYSIS OF DISCRETE & SPACE VECTOR PWM CONTROLLED HYBRID ACTIVE FILTERS FOR POWER QUALITY ENHANCEMENT , 2011 .

[5]  Narayan Prasad Gupta,et al.  Harmonic Mitigation using Shunt Active Filter at Utility end in grid connected to Renewable Source of Energy , 2012 .

[6]  V. C. Veera Reddy,et al.  Design of Shunt Active Power Filter to eliminate the harmonic cur- rents and to compensate the reactive power under distorted and/or imbalanced source voltages in steady state , 2011 .

[7]  K. Mounika,et al.  Sinusoidal and Space Vector Pulse Width Modulation for Inverter , 2013 .

[8]  M. SUNITHA,et al.  Elimination of Harmonics Using Active Power Filter Based on DQ Reference Frame Theory , 2013 .

[9]  Friedrich W. Fuchs,et al.  DC link harmonics of three phase voltage source converters influenced by the pulse width modulation strategy-an analysis , 2005 .

[10]  G. Joos,et al.  A current-source inverter fed induction motor drive system with reduced losses , 1995, IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting.

[11]  V. T. Ranganathan,et al.  A novel CSI-fed induction motor drive , 2006, IEEE Transactions on Power Electronics.