Determination of phenolic compounds by a polyphenol oxidase amperometric biosensor and artificial neural network analysis.

The determination of phenolic compounds is significant given its toxicity, even at very low concentration levels. Amperometric determination of phenols is a simple technique available. Direct oxidation of phenols can be used, but another possibility is the use of polyphenol oxidase (tyrosinase) enzyme biosensors that oxidises the phenolic compounds into their corresponding quinones. Reduction of the resulting quinones accomplishes the amplification of the amperometric signal, as long as the result of the reduction process is the corresponding cathecol, this being able to be oxidised again by the polyphenol oxidase immobilized on the surface of the biosensor. In this communication, simultaneous determination of different phenols was carried out combining biosensor measurements with chemometric tools, in what is known as electronic tongue. The departure information used was the overlapped reduction voltammogram generated with the amperometric biosensor based on polyphenol oxidase. Artificial Neural Networks (ANN) were used for extraction and quantification of each compound. Phenol, cathecol and m-cresol formed the three-analyte study case resolved in this work. Good prediction ability was attained, and so, the separate quantification of these three phenols was accomplished.

[1]  F. Céspedes,et al.  New materials for electrochemical sensing. II. Rigid carbon-polymer biocomposites , 2000 .

[2]  Natural neural networks for quantitative sensing of neurochemicals: an artificial neural network analysis , 2000 .

[3]  T. Heberer,et al.  Detection of more than 50 substituted phenols as their t-butyldimethylsilyl derivatives using gas chromatography−mass spectrometry , 1997 .

[4]  I. A. Borisov,et al.  Analysis of ethanol-glucose mixtures by two microbial sensors: application of chemometrics and artificial neural networks for data processing. , 2001, Biosensors & bioelectronics.

[5]  J M Pingarrón,et al.  Composite electrochemical biosensors: a comparison of three different electrode matrices for the construction of amperometric tyrosinase biosensors. , 2002, Biosensors & bioelectronics.

[6]  Rolf D. Schmid,et al.  A disposable multielectrode biosensor for rapid simultaneous detection of the insecticides paraoxon and carbofuran at high resolution , 1999 .

[7]  M. B. De Souza,et al.  Development of an alcohol fermentation control system based on biosensor measurements interpreted by neural networks , 2001 .

[8]  J. Pingarrón,et al.  Detection of phenolic compounds in flow systems based on tyrosinase-modified reticulated vitreous carbon electrodes. , 2001, Talanta.

[9]  J. Marty,et al.  Improved multianalyte detection of organophosphates and carbamates with disposable multielectrode biosensors using recombinant mutants of Drosophila acetylcholinesterase and artificial neural networks. , 2000, Biosensors & bioelectronics.

[10]  Marek Trojanowicz,et al.  Determination of Pesticides Using Electrochemical Enzymatic Biosensors , 2002 .

[11]  P. Hernández,et al.  An electronic tongue using potentiometric all-solid-state PVC-membrane sensors for the simultaneous quantification of ammonium and potassium ions in water , 2003, Analytical and bioanalytical chemistry.

[12]  María Cristina González,et al.  Analytical performance of commercially available and unavailable phenolic compounds using real samples by high-performance liquid chromatography–diode-array detection , 2002 .

[13]  L. Oniciu,et al.  Biosensors for phenol derivatives using biochemical signal amplification. , 2003, Talanta.

[14]  Miloslav Pravda,et al.  ROLE OF CHEMOMETRICS FOR ELECTROCHEMICAL SENSORS , 2002 .

[15]  David C. Cowell The detection and identification of metal and organic pollutants in potable water using enzyme assays suitable for sensor development , 1995 .

[16]  Bernd Hitzmann,et al.  Optical chemo- and biosensors for use in clinical applications , 1997 .

[17]  T. Scheper,et al.  Computational neural networks for the evaluation of biosensor FIA measurements , 1997 .