A noncontact intraocular pressure measurement device using a micro reflected air pressure sensor for the prediagnosis of glaucoma

This study investigates a novel, portable tonometer using a micro reflected air pressure sensor for the prediagnosis of glaucoma. Because glaucoma progresses slowly and is not painful, glaucoma patients require a portable prediagnosis system to periodically measure intraocular pressure at home. Conventionally, intraocular pressure is measured by an air-puff tonometer whereby the cornea is deformed by a short pulse of air pressure and the magnitude of the corneal deformation is measured by optic systems such as a combination of laser- and photodiodes. In this study, a micro reflected air pressure sensor was designed, fabricated, and tested in order to measure the magnitude of corneal deformation without optic systems. In an experimental study, artificial eyes with different internal pressures were fabricated and these pressures were measured by the aforementioned system.

[1]  F. Grehn,et al.  Intraocular Pressure Measurement-Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry , 2005 .

[2]  Kazuyuki Sasaki,et al.  Central corneal thickness, radius of the corneal curvature and intraocular pressure in normal subjects using non-contact techniques: Reykjavik Eye Study. , 2002, Acta ophthalmologica Scandinavica.

[3]  Rohit Varma,et al.  Implantable micromechanical parylene-based pressure sensors for unpowered intraocular pressure sensing , 2007 .

[4]  Makoto Kaneko,et al.  Dynamic Sensing of Human Eye , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[5]  R. Rössler,et al.  Tono-Pen, a new tonometer , 2005, International Ophthalmology.

[6]  R. W. Spencer,et al.  Tonography in the clinical management of glaucoma. , 1956, Transactions of the American Ophthalmological Society.

[7]  W. Chien,et al.  LARGE DEFLECTION OF A CIRCULAR CLAMPED PLATE UNDER UNIFORM PRESSURE , 1947 .

[8]  D. Shin,et al.  Comparison of the Tono-Pen to the Goldmann applanation tonometer. , 1988, Archives of ophthalmology.

[9]  D. Pye,et al.  Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo , 1999, Bulletin of mathematical biology.

[10]  David P Piñero,et al.  Corneal diameter measurements by corneal topography and angle‐to‐angle measurements by optical coherence tomography: Evaluation of equivalence , 2008, Journal of cataract and refractive surgery.

[11]  David C. Pye,et al.  Young’s Modulus in Normal Corneas and the Effect on Applanation Tonometry , 2008, Optometry and vision science : official publication of the American Academy of Optometry.

[12]  P. Tracqui,et al.  Optimization of poly-di-methyl-siloxane (PDMS) substrates for studying cellular adhesion and motility , 2008 .

[13]  D. Albert,et al.  Principles and practice of ophthalmology , 1999 .