Fault Analysis and Fault-Tolerant Method of Dual Active Bridge Converter under Triple Phase Shift Control

The open circuit fault on switches serious threat safe operation of DAB converter. In this paper, the fault phenomena of different switches during various operation condition under triple phase shift control is presented. Based on those analysis, the advanced fault diagnose which uses midpoint voltage as diagnosis criteria. It can ensure fast detect and accurate locate failure switch. After the failure switch is located, fault-tolerant is presented to maintain power transmission ability of DAB converter and ensure safe operation. Experimental result of proposed open circuit fault performance, fault diagnose method and fault-tolerant method is validated with experimental result.

[1]  Bimal K. Bose,et al.  Investigation of fault modes of voltage-fed inverter system for induction motor drive , 1992, Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting.

[2]  Yong Kang,et al.  Open-Circuit Fault Diagnosis and Fault-Tolerant Strategies for Full-Bridge DC–DC Converters , 2012, IEEE Transactions on Power Electronics.

[3]  E. Ribeiro,et al.  Fault analysis of dual active bridge converters , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.

[4]  Xinglai Ge,et al.  Open-Circuit Fault Diagnosis of Dual Active Bridge DC-DC Converter Based on Residual Analysis , 2018, 2018 IEEE International Power Electronics and Application Conference and Exposition (PEAC).

[5]  Huiqing Wen,et al.  Reactive Power and Soft-Switching Capability Analysis of Dual-Active-Bridge DC-DC Converters with Dual-Phase-Shift Control , 2015 .

[6]  Dawei Xiang,et al.  An Industry-Based Survey of Reliability in Power Electronic Converters , 2011, IEEE Transactions on Industry Applications.

[7]  Jun Huang,et al.  Unified Triple-Phase-Shift Control to Minimize Current Stress and Achieve Full Soft-Switching of Isolated Bidirectional DC–DC Converter , 2016, IEEE Transactions on Industrial Electronics.

[8]  Weidong Xiao,et al.  Nonactive Power Loss Minimization in a Bidirectional Isolated DC–DC Converter for Distributed Power Systems , 2014, IEEE Transactions on Industrial Electronics.

[9]  Weidong Xiao,et al.  Design and performance evaluation of a bidirectional isolated dc-dc converter with extended dual-phaseshift scheme , 2013 .

[10]  Huiqing Wen,et al.  Minimum-Backflow-Power Scheme of DAB-Based Solid-State Transformer With Extended-Phase-Shift Control , 2018, IEEE Transactions on Industry Applications.

[11]  Jie Chen,et al.  Minimum-Reactive-Power Scheme of Dual-Active-Bridge DC–DC Converter With Three-Level Modulated Phase-Shift Control , 2017, IEEE Transactions on Industry Applications.

[12]  Laureano Piris-Botalla,et al.  Semi-conductors faults analysis in dual active bridge DC–DC converter , 2016 .

[13]  Huiqing Wen,et al.  Reactive Power Minimization in Bidirectional DC–DC Converters Using a Unified-Phasor-Based Particle Swarm Optimization , 2018, IEEE Transactions on Power Electronics.