ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detecting stenoses.

OBJECTIVE The aim of this study was to investigate image quality and diagnostic accuracy in detecting coronary artery lesions using a 16-MDCT scanner. MATERIALS AND METHODS Thirty-seven patients (28 men, nine women) underwent unenhanced helical CT and MDCT angiography of the coronary arteries. After patients received oral beta-blocker medication, CT scans were obtained during a single breath-hold with a 16-MDCT scanner using ECG-gating (0.75-mm collimation, 2.8-mm table feed/rotation, 0.42-sec rotation time). The image quality was assessed in terms of artifacts and segment visibility by two reviewers. Stenosis severity was compared with the results of conventional invasive coronary angiography. RESULTS The data evaluation of the image quality was based on a total of 488 segments, of which 380 segments were considered to have diagnostic image quality. One hundred eight segments (22.1%) could not be sufficiently evaluated because of severe calcifications (35 segments) and motion artifacts (73 segments). The mean calcium score (Agatston score equivalent [ASE]) was 524.3 +/- 807.6. Twenty-eight (75.7%) of the 37 patients had an ASE of less than 1,000 (mean ASE, 90.8 +/- 152.3 [SD]), and nine (24.3%) patients had an ASE of 1,000 or greater (mean ASE, 1,761.0 +/- 637.6). For detecting lesions 50% or greater (without any exclusion criteria), the overall sensitivity, specificity, positive predictive value, and negative predictive value were 59%, 87%, 61%, and 87%, respectively. When limiting the number of patients to those with a calcium score of less than 1,000 ASE, the threshold-corrected sensitivity for lesions 50% or greater was 93%; specificity, 94%; positive predictive value, 68%; and negative predictive value, 99%. CONCLUSION In patients with no or moderate coronary calcification, MDCT of coronary arteries using 16-MDCT technology allows the reliable detection of coronary artery stenoses with high diagnostic accuracy. Obtaining an initial unenhanced scan was found to be mandatory to avoid performing useless examinations in patients with severe calcifications.

[1]  K. Engelmann,et al.  Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. , 2002, Radiology.

[2]  Gabriel P. Krestin,et al.  Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris , 2006, European Radiology.

[3]  J Simon,et al.  New Technical Developments in Multislice CT, Part 2: Sub-Millimeter 16-Slice Scanning and Increased Gantry Rotation Speed for Cardiac Imaging , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[4]  S. Achenbach,et al.  Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions. , 1998, The New England journal of medicine.

[5]  A. Küttner,et al.  MDCT: cardiology indications , 2003, European Radiology.

[6]  C. Becker,et al.  [Assessment of the effective dose for routine protocols in conventional CT, electron beam CT and coronary angiography]. , 1999, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[7]  Matthijs Oudkerk,et al.  Coronary angiography with multi-slice computed tomography , 2001, The Lancet.

[8]  Xiaochuan Pan,et al.  Region-of-interest reconstruction of motion-contaminated data using a weighted backprojection filtration algorithm. , 2006, Medical physics.

[9]  M F Reiser,et al.  Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gating. , 2000, AJR. American journal of roentgenology.

[10]  C. White,et al.  Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenoses. , 2001, The American journal of cardiology.

[11]  W. Bautz,et al.  Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar Reconstruction , 2003, Circulation.

[12]  C Georg,et al.  Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. , 2001, Radiology.

[13]  R. Morin,et al.  Computed tomographic angiography of the coronary arteries: techniques and applications. , 2006, Seminars in ultrasound, CT, and MR.

[14]  S. Neubauer,et al.  Three-dimensional MR coronary angiography using the navigator technique compared with conventional coronary angiography. , 1999, AJR. American journal of roentgenology.

[15]  M. Reiser,et al.  Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience. , 2000, Radiology.

[16]  E. Halpern,et al.  Sixty-four-slice multidetector computed tomography: the future of ED cardiac care. , 2007, The American journal of emergency medicine.

[17]  P. Mølstad,et al.  Limited usefulness of non-invasive coronary angiography with 16-detector multislice computer tomography at a community hospital , 2006, Scandinavian cardiovascular journal : SCJ.

[18]  J. Remy,et al.  Coronary artery imaging during preoperative CT staging: preliminary experience with 64-slice multidetector CT in 99 consecutive patients , 2007, European Radiology.

[19]  R. Frye,et al.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. , 1975, Circulation.

[20]  C. Higgins,et al.  Coronary artery stenoses: assessment with contrast-enhanced electron-beam CT and axial reconstructions. , 1998, Radiology.

[21]  M F Reiser,et al.  Current development of cardiac imaging with multidetector-row CT. , 2000, European journal of radiology.

[22]  S. Miura,et al.  Clinical significance of the coronary calcification score by multidetector row computed tomography for the evaluation of coronary stenosis in Japanese patients. , 2006, Circulation journal : official journal of the Japanese Circulation Society.

[23]  J. Debatin,et al.  [Comparison of gradient-echo and steady state free precession sequences for 3D-navigator MR angiography of coronary arteries]. , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[24]  M. Kantarci,et al.  How image quality can be improved: our experience with multidetector computed tomography coronary angiography. , 2007, Clinical imaging.

[25]  C. Claussen,et al.  Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography: experience in 94 patients. , 2002, Clinical imaging.

[26]  P. Serruys,et al.  Usefulness of multislice computed tomography for detecting obstructive coronary artery disease. , 2002, The American journal of cardiology.

[27]  C. Claussen,et al.  [Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experiences]. , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[28]  K Nikolaou,et al.  Navigator echo-based respiratory gating for three-dimensional MR coronary angiography: results from healthy volunteers and patients with proximal coronary artery stenoses. , 1999, AJR. American journal of roentgenology.

[29]  J. Debatin,et al.  Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT. , 2003, Radiology.

[30]  Stephan Achenbach,et al.  Computed tomography coronary angiography. , 2006, Journal of the American College of Cardiology.

[31]  S Schaller,et al.  Subsecond multi-slice computed tomography: basics and applications. , 1999, European journal of radiology.

[32]  Werner Moshage,et al.  Detection of Coronary Artery Stenoses by Contrast-Enhanced, Retrospectively Electrocardiographically-Gated, Multislice Spiral Computed Tomography , 2001, Circulation.

[33]  P. Hunold,et al.  Vergleich von Gradienten-Echo und steady state free precession Sequenzen zur 3D-Navigator-MR-Koronarangiographie , 2002 .

[34]  U. Mödder,et al.  Radiation exposure in multi-slice CT of the heart. , 2001, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[35]  K. Wong,et al.  The Frequency and Determinants of Calcification in Intracranial Arteries in Chinese Patients Who Underwent Computed Tomography Examinations , 2006, Cerebrovascular Diseases.

[36]  C. Claussen,et al.  Non-invasive coronary angiography with 16-slice spiral computed tomography: image quality in patients with high heart rates , 2006, European Radiology.

[37]  J. Remy,et al.  Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients , 2007, European Radiology.

[38]  Sanjiv Sharma,et al.  16-MDCT in the evaluation of coronary cameral fistula. , 2006, AJR. American journal of roentgenology.

[39]  Stefan Wesarg,et al.  Facilitating coronary artery evaluation in MDCT using a 3D automatic vessel segmentation tool , 2006, European Radiology.

[40]  G D Rubin,et al.  Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. , 2000, Radiology.

[41]  E. Wenkel,et al.  Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection. , 2002, AJR. American journal of roentgenology.

[42]  A. Kopp,et al.  Darstellung der Herzkranzgefäße im CT mittels neuer 16-Zeilen-Technologie und reduzierter Rotationszeit: Erste Erfahrungen , 2002 .

[43]  J. Remy,et al.  Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients , 2006, European Radiology.

[44]  Pedro A. Lemos,et al.  Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed Tomography , 2002, Circulation.

[45]  B. Gerber,et al.  Diagnostic accuracy of 16-slice multidetector-row CT for detection of in-stent restenosis vs detection of stenosis in nonstented coronary arteries , 2006, European Radiology.

[46]  C D Claussen,et al.  Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating. , 2003, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[47]  K Bachmann,et al.  Coronary artery stenoses: three-dimensional imaging with electrocardiographically triggered, contrast agent-enhanced, electron-beam CT. , 1995, Radiology.