DC Fault Identification in Multiterminal HVDC Systems Based on Reactor Voltage Gradient

With the increasing number of renewable generations, the prospects of long-distance bulk power transmission impels the expansion of point-to-point High Voltage Direct Current (HVDC) grid to an emerging Multi-terminal high-voltage Direct Current (MTDC) grid. The DC grid protection with faster selectivity enhances the operational continuity of the MTDC grid. Based on the reactor voltage gradient (RVG), this paper proposes a fast and reliable fault identification technique with precise discrimination of internal and external DC faults. Considering the voltage developed across the modular multilevel converter (MMC) reactor and DC terminal reactor, the RVG is formulated to characterise an internal and external DC fault. With a window of four RVG samples, the fault is detected and discriminated by the proposed main protection scheme amidst a period of five sampling intervals. Depending on the reactor current increment, a backup protection scheme is also proposed to enhance the protection reliability. The performance of the proposed scheme is validated in a four-terminal MTDC grid. The results under meaningful fault events show that the proposed scheme is capable to identify the DC fault within millisecond. Moreover, the evaluation of the protection sensitivity and robustness reveals that the proposed scheme is highly selective for a wide range of fault resistances and locations, higher sampling frequencies, and irrelevant transient events. Furthermore, the comparison results exhibit that the proposed RVG method improves the discrimination performance of the protection scheme and thereby, proves to be a better choice for future DC fault identification.

[1]  Mehedi Hassan,et al.  Impact of Meshed HVDC Grid Operation and Control on the Dynamics of AC/DC Systems , 2021, IEEE Systems Journal.

[2]  Mohammad Farshad,et al.  A Pilot Protection Scheme for Transmission Lines of Half-Bridge MMC-HVDC Grids Using Cosine Distance Criterion , 2021, IEEE Transactions on Power Delivery.

[3]  Wang Xiang,et al.  An Improved DC Fault Protection Algorithm for MMC HVDC Grids Based on Modal-Domain Analysis , 2020, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[4]  Oliver Cwikowski,et al.  HVDC Circuit Breakers–A Review , 2020, IEEE Access.

[5]  Yutian Liu,et al.  Accurate and Efficient Estimation of Short-Circuit Current for MTDC Grids Considering MMC Control , 2020, IEEE Transactions on Power Delivery.

[6]  Jinyu Wen,et al.  An Adaptive Fault Current Limiting Control for MMC and Its Application in DC Grid , 2020, IEEE Transactions on Power Delivery.

[7]  Peter Palensky,et al.  A Fast Protection of Multi-Terminal HVDC System Based on Transient Signal Detection , 2020, IEEE Transactions on Power Delivery.

[8]  Xianggen Yin,et al.  A Novel Integrated Protection for VSC-HVDC Transmission Line Based on Current Limiting Reactor Power , 2020, IEEE Transactions on Power Delivery.

[9]  Dirk Van Hertem,et al.  Systematic Approach to HVDC Circuit Breaker Sizing , 2020, IEEE Transactions on Power Delivery.

[10]  Jun Liang,et al.  A Model-Based DC Fault Location Scheme for Multi-Terminal MMC-HVDC Systems Using a Simplified Transmission Line Representation , 2020, IEEE Transactions on Power Delivery.

[11]  Rakibuzzaman Shah,et al.  Frequency regulation of multiple asynchronous grids using adaptive droop in high‐voltage direct current system , 2020, IET Generation, Transmission & Distribution.

[12]  Qiang Huang,et al.  Single‐ended line protection for MMC‐MTDC grids , 2019, IET Generation, Transmission & Distribution.

[13]  Qiang Huang,et al.  A Pilot Protection Scheme of DC Lines for Multi-Terminal HVDC Grid , 2019, IEEE Transactions on Power Delivery.

[14]  Zhao Xu,et al.  DC Fault Detection in MTDC Systems Based on Transient High Frequency of Current , 2019, IEEE Transactions on Power Delivery.

[15]  Jinyu Wen,et al.  A Transient Voltage-Based DC Fault Line Protection Scheme for MMC-Based DC Grid Embedding DC Breakers , 2019, IEEE Transactions on Power Delivery.

[16]  Abhisek Ukil,et al.  Experimental Validation of Fault Identification in VSC-Based DC Grid System , 2018, IEEE Transactions on Industrial Electronics.

[17]  Hui Pang,et al.  Research on Key Technology and Equipment for Zhangbei 500kV DC Grid , 2018, 2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia).

[18]  Aniruddha M. Gole,et al.  A Fast DC Fault Detection Method Using DC Reactor Voltages in HVdc Grids , 2018, IEEE Transactions on Power Delivery.

[19]  Mike Barnes,et al.  Stability and control of mixed AC–DC systems with VSC-HVDC: a review , 2018 .

[20]  Abhisek Ukil,et al.  Analysis and validation of wavelet transform based DC fault detection in HVDC system , 2017, Appl. Soft Comput..

[21]  Liangzhong Yao,et al.  DC Fault Detection and Location in Meshed Multiterminal HVDC Systems Based on DC Reactor Voltage Change Rate , 2017, IEEE Transactions on Power Delivery.

[22]  Nengling Tai,et al.  Transient-Voltage-Based Protection Scheme for DC Line Faults in the Multiterminal VSC-HVDC System , 2017, IEEE Transactions on Power Delivery.

[23]  Weinan Wang,et al.  Research and application on multi-terminal and DC grids based on VSC-HVDC technology in China , 2017 .

[24]  Shenxing Shi,et al.  A Directional Protection Scheme for HVDC Transmission Lines Based on Reactive Energy , 2016, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[25]  Jun Liang,et al.  Hvdc Grids: For Offshore and Supergrid of the Future , 2016 .

[26]  Cora Petino,et al.  Application of multilevel full bridge converters in HVDC multiterminal systems , 2016 .

[27]  Athula D. Rajapakse,et al.  Fault Detection and Interruption in an Earthed HVDC Grid Using ROCOV and Hybrid DC Breakers , 2015, IEEE Transactions on Power Delivery.

[28]  Simone Schweitzer,et al.  Multi Terminal Direct Current Grids Modeling Analysis And Control , 2016 .