High-resolution functional vascular assessment with ultrasound

In order to improve the resolution of contrast-assisted imaging systems, we have created a high-frequency destruction/contrast replenishment imaging system with a spatial resolution of 160 /spl mu/m /spl times/ 160 /spl mu/m. The system utilizes a 1-MHz cylindrically focused transducer for destruction and a 25-MHz spherically focused transducer for pulse/echo imaging. Speckle tracking and a clutter filter are applied across frames to remove the challenging physiologic motion artifacts that are obtained when imaging with a mechanically scanned transducer. Using a new estimation technique, flow constants proportional to absolute flow rate were estimated from B-mode time-intensity curves (TICs). The in vitro results indicate a correlation between the actual flow velocity and the estimated rate constant. In vivo images are presented showing blood perfusion in the ciliary processes and iris of the rabbit eye. The regions of interest (ROIs) from the ciliary processes yielded slower perfusion compared with the iris, as expected from vascular casts of the microcirculation in this region. Potential applications of this system include high-resolution perfusion assessment in small animals.

[1]  R E Lenkinski,et al.  Renal perfusion in humans: MR imaging with spin tagging of arterial water. , 1995, Radiology.

[2]  Helmut Ermert,et al.  Ultrasonic assessment of perfusion conditions in the brain and in the liver , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[3]  M. Nicolela,et al.  A comparative study of the effects of timolol and latanoprost on blood flow velocity of the retrobulbar vessels. , 1996, American journal of ophthalmology.

[4]  G. Michelson,et al.  Blood velocity in the ophthalmic artery in normal subjects and patients with endophthalmitis. , 1990, Investigative ophthalmology & visual science.

[5]  K.W. Ferrara,et al.  A new high resolution color flow system using an eigendecomposition-based adaptive filter for clutter rejection , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  Paul A. Dayton,et al.  Optical observation of contrast agent destruction , 2000 .

[7]  D. A. Christopher,et al.  40-MHZ echocardiography scanner for cardiovascular assessment of mouse embryos. , 1998, Ultrasound in medicine & biology.

[8]  R. Y. Chiao,et al.  Subharmonic Imaging with Microbubble Contrast Agents: Initial Results , 1999, Ultrasonic imaging.

[9]  K. Ferrara,et al.  High frequency ultrasound with an eigen-decomposition filter to assess the effect of laser cyclophotocoagulation treatment on blood flow , 2002, 2002 IEEE Ultrasonics Symposium, 2002. Proceedings..

[10]  Foster Fs,et al.  ULTRASOUND BIOMICROSCOPY: High-Frequency Ultrasound Imaging of the Eye at Microscopic Resolution , 1998 .

[11]  L From,et al.  A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging. , 1995, Ultrasound in medicine & biology.

[12]  F. Stuart Foster,et al.  High-frequency color flow imaging of the microcirculation , 2000 .

[13]  B G Zagar,et al.  Ultrasonic mapping of the microvasculature: signal alignment. , 1998, Ultrasound in medicine & biology.

[14]  R. Weinreb,et al.  The effect of topical beta-adrenoceptor blocking agents on pulsatile ocular blood flow , 1995, Eye.

[15]  F. Lizzi,et al.  High-resolution ultrasonic imaging and characterization of the ciliary body. , 2001, Investigative ophthalmology & visual science.

[16]  M. G. Bucci,et al.  Color Doppler assessment of normal ocular blood flow , 1993, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[17]  A. Ho,et al.  Color Doppler imaging of the ocular ischemic syndrome. , 1992, Ophthalmology.

[18]  Susannah H Bloch,et al.  Contrast-assisted Destruction-replenishment Ultrasound for the Assessment of Tumor Microvasculature in a Rat Model , 2002, Technology in cancer research & treatment.

[19]  K. Nightingale,et al.  A preliminary evaluation of the effects of primary and secondary radiation forces on acoustic contrast agents , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  P. Dayton,et al.  Threshold of fragmentation for ultrasonic contrast agents. , 2001, Journal of biomedical optics.

[21]  F Forsberg,et al.  Ultrasonic characterization of the nonlinear properties of contrast microbubbles. , 2000, Ultrasound in medicine & biology.

[22]  W. C. Stewart,et al.  Beta-blocker-induced complications and the patient with glaucoma. Newer treatments to help reduce systemic adverse events. , 1998, Archives of internal medicine.

[23]  M. Garwood,et al.  Imaging blood flow in brain tumors using arterial spin labeling , 2000, Magnetic resonance in medicine.

[24]  Michael F. Insana,et al.  Optimization of real-time high-frequency ultrasound for blood flow imaging in the microcirculation , 2001, SPIE Medical Imaging.

[25]  David E Goertz,et al.  High-frequency Doppler ultrasound monitors the effects of antivascular therapy on tumor blood flow. , 2002, Cancer research.

[26]  M. Dewhirst,et al.  Magnetic resonance imaging applications in the evaluation of tumor angiogenesis. , 2001, Seminars in radiation oncology.

[27]  P. Molinoff,et al.  Distribution and properties of beta-adrenergic receptors in human iris-ciliary body. , 1987, Investigative ophthalmology & visual science.

[28]  R. Silverman,et al.  Ultrasound measurement of the effect of temperature on microperfusion in the eye. , 2002, Ultrasound in medicine & biology.

[29]  E. Wisner,et al.  Subharmonic phase-inversion for tumor perfusion estimation , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[30]  W E Reddick,et al.  MR imaging of tumor microcirculation: Promise for the new millenium , 1999, Journal of magnetic resonance imaging : JMRI.

[31]  W. Castelli,et al.  Systemic side effects of topical beta‐adrenergic blockers , 1996, Clinical cardiology.

[32]  R. J. Fornaris,et al.  A swept-scanning mode for estimation of blood velocity in the microvasculature , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  P. Burns,et al.  Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[34]  T. Williamson,et al.  Ocular blood flow measurement. , 1994, The British journal of ophthalmology.

[35]  P. Dayton,et al.  Mechanisms of contrast agent destruction , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[36]  R. Sergott,et al.  Color Doppler imaging. A new noninvasive technique to diagnose and monitor carotid cavernous sinus fistulas. , 1991, Archives of ophthalmology.

[37]  Jens M. Hovem,et al.  Experimental observation of subharmonic oscillations in Infoson bubbles , 1996 .

[38]  R. Silverman,et al.  High-resolution ultrasonic imaging of blood flow in the anterior segment of the eye. , 1999, Investigative ophthalmology & visual science.

[39]  A R Jayaweera,et al.  Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. , 1998, Circulation.

[40]  Wenwu Cao,et al.  High frequency properties of passive materials for ultrasonic transducers , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[41]  J. Evelhoch,et al.  Deuterium NMR tissue perfusion measurements using the tracer uptake approach: II. comparison with microspheres in tumors , 1999, Magnetic resonance in medicine.