Pyrolysis combustion flow calorimetry

Abstract A method for evaluating the combustibility of milligram samples is described. Pyrolysis-combustion flow calorimetry (PCFC) separately reproduces the solid state and gas phase processes of flaming combustion in a nonflaming test by controlled pyrolysis of the sample in an inert gas stream followed by high temperature oxidation of the volatile pyrolysis products. Oxygen consumption calorimetry is used to measure the heat of combustion of the pyrolysis products. The maximum amount of heat released per unit mass per degree of temperature (J g−1 K−1) is a material property that appears to be a good predictor of flammability.

[1]  Richard E. Lyon,et al.  Solid-State Thermochemistry of Flaming Combustion , 1999 .

[2]  C. F. Cullis,et al.  The combustion of organic polymers , 1981 .

[3]  A. Tewarson Generation of Heat and Chemical Compounds in Fires , 2002 .

[4]  Vytenis Babrauskas Comparative Rates of Heat Release from Five Different Types of Test Apparatuses , 1986 .

[5]  Ronald A. Susott,et al.  Thermal Behavior of Conifer Needle Extractives , 1980 .

[6]  Archibald Tewarson,et al.  Experimental Evaluation of Flammability Parameters of Polymeric Materials , 1982 .

[7]  W. Deng,et al.  XV. The relation of oxygen to the heat of combustion of organic compounds , 1917 .

[8]  I. Reshetnikov,et al.  Oxidation kinetic of volatile polymer degradation products , 1999 .

[9]  Richard E. Lyon,et al.  Heats of combustion of high temperature polymers , 2000 .

[10]  William Parker,et al.  Prediction Of The Heat Release Rate Of Wood , 1986 .

[11]  T. Brill,et al.  T-Jump/FT-IR Spectroscopy: A New Entry into the Rapid, Isothermal Pyrolysis Chemistry of Solids and Liquids , 1992 .

[12]  B. Eling,et al.  Laser pyrolysis/time-of-flight mass spectrometry studies pertinent to the behaviour of flame-retarded polymers in real fire situations , 1999 .

[13]  R. N. Walters,et al.  Molar group contributions to polymer flammability , 2003 .

[14]  V. Babrauskas,et al.  The phi meter: A simple, fuel‐independent instrument for monitoring combustion equivalence ratio , 1994 .

[15]  F. H. Prager,et al.  Cone calorimetry—a review of tests carried out on plastics for the association of plastic manufacturers in Europe , 1991 .

[16]  Takashi Kashiwagi,et al.  Effects of sample mounting on flammability properties of intumescent polymers , 1993 .

[17]  W. Wendlandt Thermal methods of analysis , 1964 .

[18]  Richard D. Peacock,et al.  Heat release rate: The single most important variable in fire hazard☆ , 1990 .

[19]  Charles A. Wilkie,et al.  Fire retardancy of polymeric materials , 2000 .

[20]  F. Shafizadeh,et al.  Quantitative Thermal Analysis Technique for Combustible Gas Detection , 1979 .

[21]  Clayton Huggett,et al.  Estimation of rate of heat release by means of oxygen consumption measurements , 1980 .

[22]  A. Tewarson,et al.  Flammability of plastics—I. Burning intensity , 1976 .

[23]  G. E. Parks,et al.  Studies of methane-oxidation kinetics , 1977 .

[24]  E. Turi,et al.  Thermal characterization of polymeric materials , 1981 .

[25]  Marc Janssens,et al.  Measuring rate of heat release by oxygen consumption , 1991 .

[26]  J. Liggat Products of Thermal Degradation of Polymers , 1999 .

[27]  Joseph H. Flynn,et al.  General Treatment of the Thermogravimetry of Polymers. , 1966, Journal of research of the National Bureau of Standards. Section A, Physics and chemistry.

[28]  R. Lyon Pyrolysis kinetics of char forming polymers , 1998 .

[29]  Leonard Y. Cooper,et al.  The Role of Aircraft Panel Materials in Cabin Fires and Their Properties. , 1985 .

[30]  V. Babrauskas Heat Release In Fires , 1990 .

[31]  D. V. Krevelen Properties of Polymers , 1990 .

[32]  R. Susott Characterization of the thermal properties of forest fuels by combustible gas analysis , 1982 .

[33]  Richard E. Lyon,et al.  An Integral Method of Nonisothermal Kinetic Analysis. , 1997 .

[34]  Richard E. Lyon,et al.  Heat release kinetics , 2000 .

[35]  R. G. Hill,et al.  Evaluation of aircraft interior panels under full-scale cabin fire test conditions , 1985 .