Indoor air quality in green buildings: A case-study in a residential high-rise building in the northeastern United States

Improved indoor air quality (IAQ) is one of the critical components of green building design. Green building tax credit (e.g., New York State Green Building Tax Credit (GBTC)) and certification programs (e.g., Leadership in Energy & Environmental Design (LEED)) require indoor air quality measures and compliance with allowable maximum concentrations of common indoor air pollutants. It is not yet entirely clear whether compliance with these programs results in improved IAQ and ultimately human health. As a case in point, annual indoor air quality measurements were conducted in a residential green high-rise building for five consecutive years by an industrial hygiene contractor to comply with the building's GBTC requirements. The implementation of green design measures resulted in better IAQ compared to data in references of conventional homes for some parameters, but could not be confirmed for others. Relative humidity and carbon dioxide were satisfactory according to existing standards. Formaldehyde levels during four out of five years were below the most recent proposed exposure limits found in the literature. To some degree, particulate matter (PM) levels were lower than that in studies from conventional residential buildings. Concentrations of Volatile Organic Compounds (VOCs) with known permissible exposure limits were below levels known to cause chronic health effects, but their concentrations were inconclusive regarding cancer health effects due to relatively high detection limits. Although measured indoor air parameters met all IAQ maximum allowable concentrations in GBTC and applicable LEED requirements at the time of sampling, we argue that these measurements were not sufficient to assess IAQ comprehensively because more sensitive sampling/analytical methods for PM and VOCs are needed; in addition, there is a need for a formal process to ensure rigor and adequacy of sampling and analysis methods. Also, we suggest that a comprehensive IAQ assessment should include mixed mode thermal comfort models, semi-volatile organic compounds, assessment of new chemicals, and permissible exposure levels of many known indoor VOCs and bioaerosols. Plus, the relationship between energy consumption and IAQ, and tenant education on health effects of indoor pollutants and their sources may need more attention in IAQ investigations in green buildings.

[1]  Executive Summary,et al.  Mobile-Source Air Toxics : A Crit ical Review of the Literature on Exposure and Health Effects , 1999 .

[2]  Deborah H Bennett,et al.  Origin, occurrence, and source emission rate of acrolein in residential indoor air. , 2007, Environmental science & technology.

[3]  J. Heerwagen,et al.  The human factors of sustainable building design: post occupancy evaluation of the Philip Merrill Environmental Center , 2005 .

[4]  Peder Wolkoff,et al.  Cancer effects of formaldehyde: a proposal for an indoor air guideline value , 2010, Archives of Toxicology.

[5]  C. Weisel,et al.  Indoor air VOC concentrations in suburban and rural New Jersey. , 2008, Environmental science & technology.

[6]  Arthur M Winer,et al.  Relationships of Indoor, Outdoor, and Personal Air (RIOPA). Part I. Collection methods and descriptive analyses. , 2005, Research report.

[7]  Philipp Lirk,et al.  Mass spectrometric profile of exhaled breath—field study by PTR-MS , 2005, Respiratory Physiology & Neurobiology.

[8]  Chunrong Jia,et al.  Concentrations and emissions of polybrominated diphenyl ethers from U.S. houses and garages. , 2009, Environmental science & technology.

[9]  Warren L. Paul,et al.  A comparison of occupant comfort and satisfaction between a green building and a conventional building , 2008 .

[10]  Sonja N Sax,et al.  Differences in source emission rates of volatile organic compounds in inner-city residences of New York City and Los Angeles , 2004, Journal of Exposure Analysis and Environmental Epidemiology.

[11]  Na Li,et al.  Maximizing Information from Residential Measurements of Volatile Organic Compounds , 2013 .

[12]  R L Corsi,et al.  Reflections on the state of research: indoor environmental quality. , 2011, Indoor air.

[13]  Kimberly M. Fowler,et al.  Re-Assessing Green Building Performance: A Post Occupancy Evaluation of 22 GSA Buildings , 2010 .

[14]  W. Fisk,et al.  Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance , 2012, Environmental health perspectives.

[15]  Victoria Klug,et al.  COOKING APPLIANCE USE IN CALIFORNIA HOMES DATA COLLECTED FROM A WEB-BASED SURVEY , 2012 .

[16]  Rob Adams,et al.  Indoor environment quality and occupant productivity in the CH2 building , 2008 .

[17]  Qing Yu Meng,et al.  Fine organic particulate matter dominates indoor-generated PM2.5 in RIOPA homes , 2006, Journal of Exposure Science and Environmental Epidemiology.

[18]  Richard de Dear,et al.  Green occupants for green buildings: The missing link? , 2012 .

[19]  P. Koutrakis,et al.  Characterization of indoor particle sources: A study conducted in the metropolitan Boston area. , 1999, Environmental health perspectives.

[20]  M. Röösli,et al.  Fine particulate matter measurements in Swiss restaurants, cafés and bars: what is the effect of spatial separation between smoking and non-smoking areas? , 2010, Indoor air.

[21]  D. Hun,et al.  Formaldehyde in residences: long-term indoor concentrations and influencing factors. , 2010, Indoor air.

[22]  Gail Brager,et al.  Operable windows, personal control and occupant comfort. , 2004 .

[23]  Peder Wolkoff,et al.  Non-cancer effects of formaldehyde and relevance for setting an indoor air guideline. , 2010, Environment international.

[24]  George V. Alexeeff,et al.  Office of Environmental Health Hazard Assessment , 2013 .

[25]  Jeffrey M . Keeton The Road to Platinum: Using the USGBC's LEED-EB® Green Building Rating System to Retrofit the U.S. Environmental Protection Agency's Region 10 Park Place Office Building , 2010 .

[26]  J. Samet,et al.  Ventilation rates and health: multidisciplinary review of the scientific literature. , 2011, Indoor air.

[27]  Joon-Yeob Lee,et al.  Indoor and outdoor levels of respirable particulates (PM10) and Carbon Monoxide (CO) in high-rise apartment buildings , 2006 .

[28]  H. Bolt,et al.  New results on formaldehyde: the 2nd International Formaldehyde Science Conference (Madrid, 19–20 April 2012) , 2012, Archives of Toxicology.

[29]  Leah Zagreus,et al.  Occupant satisfaction with indoor environmental quality in green buildings , 2006 .

[30]  Edward Arens,et al.  Data Collection Methods for Assessing Adaptive Comfort in Mixed-Mode Buildings and Personal Comfort Systems , 2012 .

[31]  Nasim A. Mullen,et al.  Impact of Natural Gas Appliances on Pollutant Levels in California Homes , 2014 .

[32]  Shuncheng Lee,et al.  Investigation of indoor air quality at residential homes in Hong Kong - Case study , 2002 .

[33]  Naresh Kumar,et al.  Health Effects of Air Quality Regulations in Delhi, India. , 2011, Atmospheric environment.

[34]  B. Turpin,et al.  Estimating contributions of indoor and outdoor sources to indoor carbonyl concentrations in three urban areas of the United States , 2006 .

[35]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[36]  J M Logue,et al.  Hazard assessment of chemical air contaminants measured in residences. , 2010, Indoor air.

[37]  E. Ferrannini Of Microbes and Men , 2015, Diabetes Care.

[38]  Tunga Salthammer,et al.  Organic Indoor Air Pollutants. Occurrence, Measurement, Evaluation , 1999 .

[39]  Steven N Chillrud,et al.  Exposures to multiple air toxics in New York City. , 2002, Environmental health perspectives.

[40]  K. Kannan,et al.  Comparative assessment of human exposure to phthalate esters from house dust in China and the United States. , 2011, Environmental science & technology.

[41]  Robert Golden,et al.  Identifying an indoor air exposure limit for formaldehyde considering both irritation and cancer hazards , 2011, Critical reviews in toxicology.

[42]  P. J. Callahan,et al.  Residential environmental measurements in the National Human Exposure Assessment Survey (NHEXAS) pilot study in Arizona: preliminary results for pesticides and VOCs , 1999, Journal of Exposure Analysis and Environmental Epidemiology.

[43]  Susan Roaf Innovative approaches to the natural ventilation of buildings: the imperative for change , 2012 .