Pediatric MDCT: towards assessing the diagnostic influence of dose reduction on the detection of small lung nodules.
暂无分享,去创建一个
Ehsan Samei | James G. Colsher | Donald P. Frush | David M. DeLong | Robert P. Jones | D. DeLong | E. Samei | J. Colsher | D. Frush | Xiang Li | Xiang Li | C. Hollingsworth | A. Gaca | C. Maxfield | Caroline L. Hollingsworth | Charles M. Maxfield | Ana Maria Gaca | Robert P. Jones
[1] K. Berbaum,et al. Satisfaction of search in diagnostic radiology. , 1989, Investigative radiology.
[2] Naichang Yu,et al. Simulating solid lung nodules in MDCT images for CAD evaluation: modeling, validation, and applications , 2007, SPIE Medical Imaging.
[3] R Kikinis,et al. Spiral CT of the chest: comparison of cine and film-based viewing. , 1995, Radiology.
[4] Williams Da,et al. A test for differences between treatment means when several dose levels are compared with a zero dose control. , 1971 .
[5] Rainer Raupach,et al. The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT , 2007, European Radiology.
[6] Takeshi Johkoh,et al. Reduced radiation dose helical chest CT: effect on reader evaluation of structures and lung findings. , 2004, Radiology.
[7] M. Absalon,et al. Pulmonary nodules discovered during the initial evaluation of pediatric patients with bone and soft‐tissue sarcoma , 2008, Pediatric blood & cancer.
[8] Ehsan Samei,et al. Comparison of patient size-based methods for estimating quantum noise in CT images of the lung. , 2009, Medical physics.
[9] A J Britten,et al. The addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain. , 2004, The British journal of radiology.
[10] B. J. Winer. Statistical Principles in Experimental Design , 1992 .
[11] Willi A Kalender,et al. An extensible software-based platform for reconstruction and evaluation of CT images. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.
[12] H. Kauczor,et al. Radiation dose reduction in chest CT: a review. , 2008, AJR. American journal of roentgenology.
[13] Bernd Hamm,et al. Low-dose spiral CT: applicability to paediatric chest imaging , 1999, Pediatric Radiology.
[14] W. Heindel,et al. Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT , 2004, European Radiology.
[15] Nevzat Karabulut,et al. Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules , 2002, European Radiology.
[16] M. M. Zhang,et al. Usefulness of low-dose CT in the detection of pulmonary metastasis of gestational trophoblastic tumours. , 2007, Clinical radiology.
[17] A R Feinstein,et al. Context bias. A problem in diagnostic radiology. , 1996, JAMA.
[18] H Rusinek,et al. Pulmonary nodule detection: low-dose versus conventional CT. , 1998, Radiology.
[19] Harold L. Kundel,et al. Handbook of Medical Imaging, Volume 1. Physics and Psychophysics , 2000 .
[20] C. Metz. ROC Methodology in Radiologic Imaging , 1986, Investigative radiology.
[21] E. Samei,et al. Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems. , 1999, Medical physics.
[22] K. Zou,et al. Multidetector CT of the paranasal sinus: potential for radiation dose reduction. , 2007, Radiology.
[23] K. Berbaum,et al. Receiver operating characteristic rating analysis. Generalization to the population of readers and patients with the jackknife method. , 1992, Investigative radiology.
[24] Jie Zhang,et al. Paediatric CT: the effects of increasing image noise on pulmonary nodule detection , 2008, Pediatric Radiology.
[25] Madan M. Rehani,et al. Effect of reduction in tube current on reader confidence in paediatric computed tomography. , 2005, Clinical radiology.
[26] D. A. Williams,et al. A test for differences between treatment means when several dose levels are compared with a zero dose control. , 1971, Biometrics.
[27] Denis Tack,et al. Multi-detector row CT pulmonary angiography: comparison of standard-dose and simulated low-dose techniques. , 2005, Radiology.
[28] A. Leung,et al. Simulated dose reduction in conventional chest CT: validation study. , 1997, Radiology.
[29] T M Yelbuz,et al. Pulmonary nodules: experimental and clinical studies at low-dose CT. , 1999, Radiology.
[30] Radiation dose in computed tomography of the chest. , 2004, JBR-BTR : organe de la Societe royale belge de radiologie (SRBR) = orgaan van de Koninklijke Belgische Vereniging voor Radiologie.
[31] E Samei,et al. Three-dimensional simulation of lung nodules for paediatric multidetector array CT. , 2009, The British journal of radiology.
[32] Hoen-oh Shin,et al. Insertion of virtual pulmonary nodules in CT data of the chest: development of a software tool , 2006, European Radiology.
[33] Kevin S. Berbaum,et al. Monte Carlo validation of a multireader method for receiver operating characteristic discrete rating data: split-plot experimental design , 1999, Medical Imaging.
[34] G. Enríquez,et al. Low-dose high-resolution CT of the chest in children and young adults: dose, cooperation, artifact incidence, and image quality. , 2000, AJR. American journal of roentgenology.
[35] Jiang Hsieh,et al. Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. , 2002, AJR. American journal of roentgenology.
[36] L. Tanoue. Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .