Impedance-Based Interactions in Grid-Tied Three-Phase Inverters in Renewable Energy Applications

Impedance-ratio-based interaction analyses in terms of stability and performance of DC-DC converters is well established. Similar methods are applied to grid-connected three-phase converters as well, but the multivariable nature of the converters and the grid makes these analyses very complex. This paper surveys the state of the interaction analyses in the grid-connected three-phase converters, which are used in renewable-energy applications. The surveys show clearly that the impedance-ratio-based stability assessment are usually performed neglecting the cross-couplings between the impedance elements for reducing the complexity of the analyses. In addition, the interactions, which affect the transient performance, are not treated usually at all due to the missing of the corresponding analytic formulations. This paper introduces the missing formulations as well as explicitly showing that the cross-couplings of the impedance elements have to be taken into account for the stability assessment to be valid. In addition, this paper shows that the most accurate stability information can be obtained by means of the determinant related to the associated multivariable impedance ratio. The theoretical findings are also validated by extensive experimental measurements.

[1]  Friedrich W. Fuchs,et al.  Modeling of inverter output impedance for stability analysis in combination with measured grid impedances , 2015, 2015 IEEE 6th International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[2]  Tuomas Messo,et al.  MIMO-Identification Techniques for Rapid Impedance-Based Stability Assessment of Three-Phase Systems in DQ Domain , 2018, IEEE Transactions on Power Electronics.

[3]  Dongsheng Yang,et al.  Impact of Synchronization Phase Dynamics on DQ Impedance Measurement , 2018, 2018 IEEE 19th Workshop on Control and Modeling for Power Electronics (COMPEL).

[4]  F. Blaabjerg,et al.  Control of Power Converters in AC Microgrids , 2012, IEEE Transactions on Power Electronics.

[5]  Fred C. Lee,et al.  Impedance specifications for stable DC distributed power systems , 2002 .

[6]  Bo Wen,et al.  Small-Signal Stability Analysis of Three-Phase AC Systems in the Presence of Constant Power Loads Based on Measured d-q Frame Impedances , 2015, IEEE Transactions on Power Electronics.

[7]  Moshe Sitbon,et al.  Solar Irradiation Independent Expression for Photovoltaic Generator Maximum Power Line , 2017, IEEE Journal of Photovoltaics.

[8]  Frede Blaabjerg,et al.  Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System , 2014, IEEE Transactions on Power Electronics.

[9]  Pierluigi Siano,et al.  Constant power loads (CPL) with microgrids: problem definition, stability analysis and compensation techniques , 2017 .

[10]  Scott D. Sudhoff,et al.  Admittance space stability analysis of power electronic systems , 2000, IEEE Trans. Aerosp. Electron. Syst..

[11]  Frede Blaabjerg,et al.  Impedance-Based Analysis of DC-Link Voltage Dynamics in Voltage-Source Converters , 2019, IEEE Transactions on Power Electronics.

[12]  Fred C. Lee,et al.  A method of defining the load impedance specification for a stable distributed power system , 1993 .

[13]  Marta Molinas,et al.  Self-Synchronization of Wind Farm in an MMC-Based HVDC System: A Stability Investigation , 2017, IEEE Transactions on Energy Conversion.

[14]  R.D. Middlebrook,et al.  Low-Frequency Characterization of Switched dc-dc Converters , 1972, IEEE Transactions on Aerospace and Electronic Systems.

[15]  Frede Blaabjerg,et al.  Couplings in Phase Domain Impedance Modeling of Grid-Connected Converters , 2016, IEEE Transactions on Power Electronics.

[16]  Jing Wang,et al.  Design of a Generalized Control Algorithm for Parallel Inverters for Smooth Microgrid Transition Operation , 2015, IEEE Transactions on Industrial Electronics.

[17]  Lennart Harnefors,et al.  Passivity-Based Controller Design of Grid-Connected VSCs for Prevention of Electrical Resonance Instability , 2015, IEEE Transactions on Industrial Electronics.

[18]  Leon O. Chua,et al.  Nonlinear resistive maximum power theorem, with solar cell application , 1983 .

[19]  A. Kuperman,et al.  On the Similarity Between Low-frequency Equivalent Circuits of Photovoltaic and Wind Generators , 2015, IEEE Transactions on Energy Conversion.

[20]  Lennart Harnefors,et al.  Modeling of Three-Phase Dynamic Systems Using Complex Transfer Functions and Transfer Matrices , 2007, IEEE Transactions on Industrial Electronics.

[21]  Dylan Dah-Chuan Lu,et al.  Modeling and analysis of current harmonic distortion from grid connected PV inverters under different operating conditions , 2013 .

[22]  Hua Lin,et al.  Stability Analysis of Grid-Connected Converters with Different Implementations of Adaptive PR Controllers under Weak Grid Conditions , 2018 .

[23]  T. Suntio,et al.  Impedance-Based Stability and Transient-Performance Assessment Applying Maximum Peak Criteria , 2013, IEEE Transactions on Power Electronics.

[24]  Barry W. Williams,et al.  Wind Turbine Power Coefficient Analysis of a New Maximum Power Point Tracking Technique , 2013, IEEE Transactions on Industrial Electronics.

[25]  Enrico Santi,et al.  Comprehensive Review of Stability Criteria for DC Power Distribution Systems , 2014, IEEE Transactions on Industry Applications.

[26]  Alon Kuperman,et al.  Analytical Derivation of Electrical-Side Maximum Power Line for Wind Generators , 2017 .

[27]  R. D. Middlebrook The two extra element theorem , 1991, Proceedings Frontiers in Education Twenty-First Annual Conference. Engineering Education in a New World Order.

[28]  Jon Are Suul,et al.  Impedance-compensated grid synchronisation for extending the stability range of weak grids with voltage source converters , 2016 .

[29]  G. Agranovich,et al.  Comparison of photovoltaic and wind generators as dynamic input sources to power processing interfaces , 2016, 2016 2nd International Conference on Intelligent Energy and Power Systems (IEPS).

[30]  Tuomas Messo,et al.  Effect of Active Damping on Output Impedance of Three-Phase Grid-Connected Converter , 2017, IEEE Transactions on Industrial Electronics.

[31]  Chun Li,et al.  Unstable Operation of Photovoltaic Inverter From Field Experiences , 2018, IEEE Transactions on Power Delivery.

[32]  Jian Sun,et al.  Voltage Stability and Control of Offshore Wind Farms With AC Collection and HVDC Transmission , 2014, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[33]  Markus Fischer,et al.  Process and tools for optimising wind power projects connected to weak grids , 2017 .

[34]  Alon Kuperman,et al.  Grid-Forming-Mode Operation of Boost-Power-Stage Converter in PV-Generator-Interfacing Applications , 2017 .

[35]  Jian Sun,et al.  Adaptive Control of Grid-Connected Inverters Based on Online Grid Impedance Measurements , 2014, IEEE Transactions on Sustainable Energy.

[36]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[37]  Raymond A. DeCarlo,et al.  Linear Circuit Analysis , 1995 .

[38]  Jinjun Liu,et al.  Infinity-Norm of Impedance-Based Stability Criterion for Three-Phase AC Distributed Power Systems With Constant Power Loads , 2015, IEEE Transactions on Power Electronics.

[39]  Teuvo Suntio,et al.  Grid-connected PV power plant induced power quality problems — Experimental evidence , 2016, 2016 18th European Conference on Power Electronics and Applications (EPE'16 ECCE Europe).

[40]  Marta Molinas,et al.  Understanding the Origin of Oscillatory Phenomena Observed Between Wind Farms and HVdc Systems , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[41]  Bo Wen,et al.  Inverse Nyquist Stability Criterion for Grid-Tied Inverters , 2017, IEEE Transactions on Power Electronics.

[42]  Jose A. Cobos,et al.  Effect of Control Method on Impedance-Based Interactions in a Buck Converter , 2013, IEEE Transactions on Power Electronics.

[43]  J. J. Biess,et al.  Some design aspects concerning input filters for DC-DC converters , 1971 .

[44]  Teuvo Suntio,et al.  Issues on Solar-Generator Interfacing With Current-Fed MPP-Tracking Converters , 2010, IEEE Transactions on Power Electronics.

[45]  Nadarajah Mithulananthan,et al.  Identification of modal interaction and small signal stability in autonomous microgrid operation , 2018 .

[46]  Nadarajah Mithulananthan,et al.  Stability of Renewable Energy based Microgrid in Autonomous Operation , 2017 .

[47]  Remus Teodorescu,et al.  Harmonic current prediction by impedance modeling of grid-tied inverters: A 1.4 MW PV plant case study , 2017 .

[48]  C. Desoer,et al.  On the generalized Nyquist stability criterion , 1979, 1979 18th IEEE Conference on Decision and Control including the Symposium on Adaptive Processes.

[49]  T. Messo,et al.  An accurate small-signal model of a three-phase VSI-based photovoltaic inverter with LCL-filter , 2015, 2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia).

[50]  Friedrich W. Fuchs,et al.  Measurement results and performance analysis of the grid impedance in different low voltage grids for a wide frequency band to support grid integration of renewables , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[51]  I. Postlethwaite,et al.  The generalized Nyquist stability criterion and multivariable root loci , 1977 .

[52]  Jian Sun,et al.  Impedance-Based Stability Criterion for Grid-Connected Inverters , 2011, IEEE Transactions on Power Electronics.

[53]  R. D. Middlebrook,et al.  Input filter considerations in design and application of switching regulators. , 1976 .

[54]  A. E. Hammad,et al.  DC Transmission Terminating at Low Short Cirucit Ratio Locations , 1986, IEEE Transactions on Power Delivery.

[55]  Julian Blanchard,et al.  History of electrical resonance , 1941, Electrical Engineering.

[56]  Teuvo Suntio,et al.  Simple VSI-based single-phase inverter: Dynamical effect of photovoltaic generator and multiplier-based grid synchronization , 2011 .

[57]  Xiongfei Wang,et al.  General Rules of Using Bode Plots for Impedance-Based Stability Analysis , 2018, 2018 IEEE 19th Workshop on Control and Modeling for Power Electronics (COMPEL).

[58]  Wei Du,et al.  Voltage-Source Control of PV Inverter in a CERTS Microgrid , 2014, IEEE Transactions on Power Delivery.

[59]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[60]  Tuomas Messo,et al.  Frequency Response Analysis of Load Effect on Dynamics of Grid-Forming Inverter , 2018, 2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia).

[61]  Oriol Gomis-Bellmunt,et al.  Impedance Modelling and Parametric Sensitivity of a VSC-HVDC System: New Insights on Resonances and Interactions , 2018 .

[62]  Teuvo Suntio,et al.  Dynamic Profile of Switched-Mode Converter , 2009 .

[63]  Dushan Boroyevich,et al.  An algorithm and implementation system for measuring impedance in the D-Q domain , 2011, 2011 IEEE Energy Conversion Congress and Exposition.

[64]  A. Gole,et al.  Impact of Short-Circuit Ratio and Phase-Locked-Loop Parameters on the Small-Signal Behavior of a VSC-HVDC Converter , 2014, IEEE Transactions on Power Delivery.

[65]  H. Nyquist,et al.  The Regeneration Theory , 1954, Journal of Fluids Engineering.

[66]  Bo Wen,et al.  AC Stability Analysis and dq Frame Impedance Specifications in Power-Electronics-Based Distributed Power Systems , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[67]  Bo Wen,et al.  Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions , 2015, IEEE Transactions on Industrial Electronics.

[68]  Gianfranco Chicco,et al.  Experimental assessment of the waveform distortion in grid-connected photovoltaic installations , 2009 .

[69]  Bo Wen,et al.  Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters , 2014, IEEE Transactions on Power Electronics.

[70]  Young-Ho Cho,et al.  Impedance-based stability analysis in grid interconnection impact study owing to the increased adoption of converter-interfaced generators , 2017 .

[71]  Slobodan Cuk,et al.  A general unified approach to modelling switching-converter power stages , 1976, 1970 IEEE Power Electronics Specialists Conference.

[72]  Seppo Valkealahti,et al.  Effect of Photovoltaic Generator Components on the Number of MPPs Under Partial Shading Conditions , 2013, IEEE Transactions on Energy Conversion.

[73]  A. Iturregi,et al.  Review of grid connection requirements for generation assets in weak power grids , 2015 .

[74]  Maciejowsk Multivariable Feedback Design , 1989 .

[75]  Tuomas Messo,et al.  Generalized multivariable small-signal model of three-phase grid-connected inverter in DQ-domain , 2015, 2015 IEEE 16th Workshop on Control and Modeling for Power Electronics (COMPEL).

[76]  S. Adloff,et al.  Control of wind power plants utilizing voltage source converter in high impedance grids , 2012, 2012 IEEE Power and Energy Society General Meeting.

[77]  Josep M. Guerrero,et al.  Stability analysis of DC microgrids with constant power load under distributed control methods , 2017, Autom..

[78]  Lakshan Piyasinghe,et al.  Impedance-model-based MIMO analysis of power synchronization control , 2018 .

[79]  Xu Cai,et al.  Properties and physical interpretation of the dynamic interactions between voltage source converters and grid: electrical oscillation and its stability control , 2017 .

[80]  P.J.M. Heskes,et al.  Harmonic interaction between a large number of distributed power inverters and the distribution network , 2004, IEEE Transactions on Power Electronics.

[81]  Frede Blaabjerg,et al.  Unified Impedance Model of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Power Electronics.

[82]  Tuomas Messo,et al.  Negative output impedance in three-phase grid-connected renewable energy source inverters based on reduced-order model , 2011 .

[83]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[84]  R. D. Middlebrook,et al.  Null double injection and the extra element theorem , 1989 .

[85]  Innocent Kamwa,et al.  Oscillatory stability assessment of microgrid in autonomous operation with uncertainties , 2017 .