Nonlinear analysis of arterial oscillated flow in experimental stenosis and microsurgical anastomosis.

BACKGROUND Thrombotic vascular occlusion is one of the main complications that can occur during microsurgical anastomosis and is frequent when the blood becomes turbulent. The aim of this ex vivo study was to test the use of nonlinear mathematical tools to detect turbulence flow upstream and downstream of an arterial stenosis and of a microsurgical anastomosis technique in arteries with diameters in the range of microsurgical practice. MATERIALS AND METHODS Rat carotid arteries (0.8 to 1.2 mm diameter) were transferred to a flow chamber and perfused with Krebs solution. An oscillated vascular flow was initiated with a peristaltic pump and a transit time flowmeter was used to measure flow with two probes. An arterial stenosis was created by a ligature and progressively increased ranging from 0 to 95%. For each flow signal three nonlinear analytical procedures were applied: time-delayed procedures, correlation dimension, and computing of the largest Lyapunov exponent. RESULTS Our results indicated that the level of turbulence flow is correlated with the area reduction stenosis. In the range of 60-95% area reduction stenosis, we noted an experimental increase of turbulence flow. We also founded that a classical end-to-end anastomosis technique induced an increase of the turbulence flow in comparison with a control artery. CONCLUSIONS Thus nonlinear analysis can be useful in characterizing the complexity of an oscillated flow in small arteries submitted to stenosis or microsurgical anastomosis and may have clinical uses in detecting high level turbulent flow after microsurgery.

[1]  David Ruelle,et al.  Strange attractors , 1980 .

[2]  W. Shaw,et al.  Comparison of continuous and interrupted suture techniques in microvascular anastomosis. , 1982, Surgery, gynecology & obstetrics.

[3]  Henry D. I. Abarbanel,et al.  Analysis of Observed Chaotic Data , 1995 .

[4]  F. Takens Detecting strange attractors in turbulence , 1981 .

[5]  K. Hutchison Doppler ultrasound spectral shape downstream of significant arterial stenosis in vivo. , 1995, Ultrasound in medicine & biology.

[6]  L. Glass,et al.  Understanding Nonlinear Dynamics , 1995 .

[7]  D. Edwards,et al.  Integration of non-linear cellular mechanisms regulating microvascular perfusion , 1999, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  T. M. Griffith,et al.  Modulation of chaotic pressure oscillations in isolated resistance arteries by EDRF. , 1993, European heart journal.

[9]  P. Grassberger,et al.  Measuring the Strangeness of Strange Attractors , 1983 .

[10]  P B Persson,et al.  Chaos in blood pressure control. , 1996, Cardiovascular research.

[11]  M. Hahn,et al.  Nonlinear analysis of blood flux in human vessels. , 1999, Physics in medicine and biology.

[12]  H. Kantz,et al.  Nonlinear time series analysis , 1997 .

[13]  J. Blackburn,et al.  Inverting chaos: Extracting system parameters from experimental data. , 1996, Chaos.

[14]  D. Parthimos,et al.  Comparison of chaotic and sinusoidal vasomotion in the regulation of microvascular flow. , 1996, Cardiovascular research.

[15]  Simon C Watkins,et al.  Pulsatile perfusion system for ex vivo investigation of biochemical pathways in intact vascular tissue. , 1996, The American journal of physiology.

[16]  J. Siebert,et al.  Transient Postoperative Stenosis in Small-Vessel Anastomoses , 1995, Annals of Plastic Surgery.

[17]  W. Shaw,et al.  Simultaneous comparison of pre‐ and post‐microanastomotic hemodynamic profiles using a Tandem Doppler Probe , 1991, Microsurgery.

[18]  L Glass,et al.  Time series analysis of complex dynamics in physiology and medicine. , 1993, Medical progress through technology.

[19]  James Theiler,et al.  Testing for nonlinearity in time series: the method of surrogate data , 1992 .

[20]  O E Jensen,et al.  Chaotic oscillations in a simple collapsible-tube model. , 1992, Journal of biomechanical engineering.

[21]  W. Welch,et al.  Validation of miniature ultrasonic transit-time flow probes for measurement of renal blood flow in rats. , 1995, The American journal of physiology.

[22]  F. Takens,et al.  Occurrence of strange AxiomA attractors near quasi periodic flows onTm,m≧3 , 1978 .

[23]  A. Groisman,et al.  Elastic turbulence in a polymer solution flow , 2000, Nature.

[24]  T J Pedley Nonlinear pulse wave reflection at an arterial stenosis. , 1983, Journal of biomechanical engineering.

[25]  G. Nilsson,et al.  Laser-Doppler perfusion imaging of microvascular blood flow in rabbit tenuissimus muscle. , 1995, The American journal of physiology.

[26]  F. Takens,et al.  On the nature of turbulence , 1971 .

[27]  C. Gaudin,et al.  Validation of 1- and 2-mm transit-time ultrasound flow probes on mesenteric artery and aorta of rats. , 1995, The American journal of physiology.

[28]  A. Wolf,et al.  Determining Lyapunov exponents from a time series , 1985 .

[29]  P B Persson,et al.  Nonlinear chaotic dynamics of arterial blood pressure and renal blood flow. , 1995, The American journal of physiology.

[30]  A Garfinkel,et al.  Controlling cardiac chaos. , 1992, Science.

[31]  Jacques Padet Fluides en écoulement , 1990 .

[32]  G Cloutier,et al.  Changes in ultrasonic Doppler backscattered power downstream of concentric and eccentric stenoses under pulsatile flow. , 1995, Ultrasound in medicine & biology.

[33]  T. Griffith,et al.  Temporal chaos in the microcirculation. , 1996, Cardiovascular research.