Coated blade spray: shifting the paradigm of direct sample introduction to MS.

Coated blade spray (CBS) is a solid-phase microextraction-based technology that can be directly coupled to MS to enable the rapid qualitative and quantitative analysis of complex matrices. The goal of this mini review is to concisely introduce CBS's operational fundamentals and to consider how it correlates/contrasts with existing direct-to-MS technologies suitable for bioanalytical applications. In addition, we provide a fair comparison of CBS to other existing solid-phase microextraction-to-MS approaches, as well as an overview of recent CBS applications/strategies that have been developed to analyze diverse compounds present in biofluids.

[1]  V. P. Miller SPE-MS analysis of absorption, distribution, metabolism and excretion assays: a tool to increase throughput and steamline workflow. , 2012, Bioanalysis.

[2]  J. Pawliszyn,et al.  High throughput quantification of prohibited substances in plasma using thin film solid phase microextraction. , 2014, Journal of chromatography. A.

[3]  J. Pawliszyn,et al.  Solid Phase Microextraction On-Fiber Derivatization Using a Stable, Portable, and Reusable Pentafluorophenyl Hydrazine Standard Gas Generating Vial. , 2016, Analytical chemistry.

[4]  J. Pawliszyn,et al.  Open Port Probe Sampling Interface for the Direct Coupling of Biocompatible Solid-Phase Microextraction to Atmospheric Pressure Ionization Mass Spectrometry. , 2017, Analytical chemistry.

[5]  Zheng Ouyang,et al.  Paper spray for direct analysis of complex mixtures using mass spectrometry. , 2010, Angewandte Chemie.

[6]  J. Pawliszyn,et al.  Rapid and Concomitant Analysis of Pharmaceuticals in Treated Wastewater by Coated Blade Spray Mass Spectrometry. , 2017, Environmental science & technology.

[7]  Janusz Pawliszyn,et al.  A study of thin film solid phase microextraction methods for analysis of fluorinated benzoic acids in seawater. , 2016, Journal of chromatography. A.

[8]  R. Zenobi,et al.  Direct Coupling of Solid-Phase Microextraction with Mass Spectrometry: Sub-pg/g Sensitivity Achieved Using a Dielectric Barrier Discharge Ionization Source. , 2016, Analytical chemistry.

[9]  D. Drexler,et al.  Coupling Laser Diode Thermal Desorption with Acoustic Sample Deposition to Improve Throughput of Mass Spectrometry–Based Screening , 2016, Journal of biomolecular screening.

[10]  A. Jarmusch,et al.  Ambient Ionization Mass Spectrometry for Point-of-Care Diagnostics and Other Clinical Measurements. , 2016, Clinical chemistry.

[11]  Abraham K. Badu-Tawiah,et al.  Direct Biofluid Analysis Using Hydrophobic Paper Spray Mass Spectrometry. , 2016, Analytical chemistry.

[12]  J. Shiea,et al.  Application of direct electrospray probe to analyze biological compounds and to couple to solid-phase microextraction to detect trace surfactants in aqueous solution. , 1999, Analytical chemistry.

[13]  Florin Marcel Musteata,et al.  Automated solid-phase microextraction and thin-film microextraction for high-throughput analysis of biological fluids and ligand–receptor binding studies , 2010, Nature Protocols.

[14]  J. Pawliszyn,et al.  Biocompatible Solid-Phase Microextraction Nanoelectrospray Ionization: An Unexploited Tool in Bioanalysis. , 2016, Analytical chemistry.

[15]  C. Yuan,et al.  Interfaces to connect thin-layer chromatography with electrospray ionization mass spectrometry. , 2003, Analytical chemistry.

[16]  Z. Takáts,et al.  Analysis of wastewater samples by direct combination of thin-film microextraction and desorption electrospray ionization mass spectrometry. , 2012, The Analyst.

[17]  J. Pawliszyn,et al.  Solid phase microextraction with thermal desorption using fused silica optical fibers , 1990 .

[18]  A. Venter,et al.  Mechanisms of real-time, proximal sample processing during ambient ionization mass spectrometry. , 2014, Analytical chemistry.

[19]  J. Pawliszyn,et al.  Ultrafast Screening and Quantitation of Pesticides in Food and Environmental Matrices by Solid-Phase Microextraction-Transmission Mode (SPME-TM) and Direct Analysis in Real Time (DART). , 2017, Analytical chemistry.

[20]  U. Gerhard,et al.  Direct ionization of solid-phase microextraction fibers for quantitative drug bioanalysis: from peripheral circulation to mass spectrometry detection. , 2015, Analytical chemistry.

[21]  Christopher J Welch,et al.  Overcoming "speed limits" in high throughput chromatographic analysis. , 2017, Journal of chromatography. A.

[22]  Tiangang Luan,et al.  Surface-coated wooden-tip electrospray ionization mass spectrometry for determination of trace fluoroquinolone and macrolide antibiotics in water. , 2017, Analytica chimica acta.

[23]  J. Pawliszyn,et al.  Introduction of solid-phase microextraction as a high-throughput sample preparation tool in laboratory analysis of prohibited substances. , 2014, Analytica chimica acta.

[24]  R. Cooks,et al.  Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization , 2004, Science.

[25]  Gangfeng Ouyang,et al.  Coupling solid-phase microextraction with ambient mass spectrometry: Strategies and applications , 2016 .

[26]  Chiara Cordero,et al.  Non-separative headspace solid phase microextraction-mass spectrometry profile as a marker to monitor coffee roasting degree. , 2013, Journal of agricultural and food chemistry.

[27]  J. Pawliszyn,et al.  Quantitative analysis of biofluid spots by coated blade spray mass spectrometry, a new approach to rapid screening , 2017, Scientific Reports.

[28]  M. Liechti,et al.  Development and validation of a rapid turboflow LC-MS/MS method for the quantification of LSD and 2-oxo-3-hydroxy LSD in serum and urine samples of emergency toxicological cases , 2015, Analytical and Bioanalytical Chemistry.

[29]  J. Pawliszyn,et al.  High-Throughput Screening and Quantitation of Target Compounds in Biofluids by Coated Blade Spray-Mass Spectrometry. , 2017, Analytical chemistry.

[30]  Nathaly Reyes-Garcés,et al.  Fast quantitation of opioid isomers in human plasma by differential mobility spectrometry/mass spectrometry via SPME/open-port probe sampling interface. , 2017, Analytica chimica acta.

[31]  J. Pawliszyn,et al.  Optimization of solid phase microextraction for non-lethal in vivo determination of selected pharmaceuticals in fish muscle using liquid chromatography-mass spectrometry. , 2012, Journal of chromatography. A.

[32]  X. Wang,et al.  Online coupling of in-tube solid-phase microextraction with direct analysis in real time mass spectrometry for rapid determination of triazine herbicides in water using carbon-nanotubes-incorporated polymer monolith. , 2014, Analytical chemistry.

[33]  Emanuela Gionfriddo,et al.  Towards on-site analysis of complex matrices by solid-phase microextraction-transmission mode coupled to a portable mass spectrometer via direct analysis in real time. , 2017, The Analyst.

[34]  Brian T Veach,et al.  RapidFire Mass Spectrometry with Enhanced Throughput as an Alternative to Liquid-Liquid Salt Assisted Extraction and LC/MS Analysis for Sulfonamides in Honey. , 2017, Analytical chemistry.

[35]  Dong Wei,et al.  Online and automated sample extraction. , 2015, Bioanalysis.

[36]  R. Cooks,et al.  Analysis of pesticide residues by leaf spray mass spectrometry , 2012 .

[37]  Barbara Bojko,et al.  SPME--quo vadis? , 2012, Analytica chimica acta.

[38]  Tiangang Luan,et al.  Surface-coated probe nanoelectrospray ionization mass spectrometry for analysis of target compounds in individual small organisms. , 2015, Analytical chemistry.

[39]  Wei Xu,et al.  Molecularly Imprinted Membrane Electrospray Ionization for Direct Sample Analyses. , 2017, Analytical chemistry.

[40]  Sergio C. Nanita,et al.  Emerging flow injection mass spectrometry methods for high-throughput quantitative analysis , 2015, Analytical and Bioanalytical Chemistry.

[41]  Wei Xu,et al.  Membrane electrospray ionization for direct ultrasensitive biomarker quantitation in biofluids using mass spectrometry. , 2015, Analytical chemistry.

[42]  Shenghong Hu,et al.  Rapid Identification of Unknown Organic Iodine in Small-Volume Complex Biological Samples Based on Nanospray Mass Spectrometry Coupled with in-Tube Solid Phase Microextraction. , 2017, Analytical chemistry.

[43]  J. Pawliszyn,et al.  Development of a Biocompatible In-Tube Solid-Phase Microextraction Device: A Sensitive Approach for Direct Analysis of Single Drops of Complex Matrixes. , 2016, Analytical chemistry.

[44]  J. Pawliszyn,et al.  Development of coated blade spray ionization mass spectrometry for the quantitation of target analytes present in complex matrices. , 2014, Angewandte Chemie.

[45]  Nicholas E. Manicke,et al.  Development of a Paper Spray Mass Spectrometry Cartridge with Integrated Solid Phase Extraction for Bioanalysis. , 2015, Analytical chemistry.

[46]  J. Pawliszyn,et al.  Fast Quantitation of Target Analytes in Small Volumes of Complex Samples by Matrix-Compatible Solid-Phase Microextraction Devices. , 2016, Angewandte Chemie.

[47]  J. Pawliszyn,et al.  Solid phase microextraction devices prepared on plastic support as potential single-use samplers for bioanalytical applications. , 2015, Analytical chemistry.

[48]  Nicholas E. Manicke,et al.  Analysis of biofluids by paper spray MS: advances and challenges. , 2016, Bioanalysis.

[49]  Sichun Zhang,et al.  Coupling a solid phase microextraction (SPME) probe with ambient MS for rapid enrichment and detection of phosphopeptides in biological samples. , 2015, The Analyst.

[50]  A. Jarmusch,et al.  Direct drug analysis from oral fluid using medical swab touch spray mass spectrometry. , 2015, Analytica chimica acta.

[51]  Nathaly Reyes-Garcés,et al.  Advances in Solid Phase Microextraction and Perspective on Future Directions. , 2018, Analytical chemistry.

[52]  E. Woolf,et al.  A device for dried blood microsampling in quantitative bioanalysis: overcoming the issues associated blood hematocrit. , 2015, Bioanalysis.

[53]  J. Mei Dried Blood Spot Sample Collection, Storage, and Transportation , 2014 .

[54]  T. V. van Beek,et al.  Biochip Spray: Simplified Coupling of Surface Plasmon Resonance Biosensing and Mass Spectrometry , 2017, Analytical chemistry.

[55]  Young-Mo Kim,et al.  SPE-IMS-MS: An automated platform for sub-sixty second surveillance of endogenous metabolites and xenobiotics in biofluids , 2016, Clinical mass spectrometry.

[56]  J. Pawliszyn,et al.  Ultra‐fast quantitation of voriconazole in human plasma by coated blade spray mass spectrometry , 2017, Journal of pharmaceutical and biomedical analysis.

[57]  J. Pawliszyn,et al.  Solid phase microextraction (SPME)-transmission mode (TM) pushes down detection limits in direct analysis in real time (DART). , 2014, Chemical communications.

[58]  J. Pawliszyn,et al.  In vivo and ex vivo SPME: a low invasive sampling and sample preparation tool in clinical bioanalysis. , 2014, Bioanalysis.

[59]  J. Pawliszyn,et al.  In vivo solid-phase microextraction for tissue bioanalysis. , 2012, Bioanalysis.

[60]  J. Pawliszyn,et al.  Solid-phase microextraction in metabolomics , 2014 .