In order to test HP turbine stages under engine representative conditions on a heat transfer point of view, blow-down test rigs are often used. In these rigs the evolution of gas temperature, pressure, and density is similar to a step function. Hence, the use of hot-wires, which are sensitive to flow velocity, density, and temperature, is more difficult than in an incompressible flow at constant temperature. This investigation describes how the data reduction can be performed in such an environment in order to extract the velocity. The gas temperature is measured with a thermocouple and the gas density is derived from the measurement of the total pressure thanks to an iterative procedure. Once the velocity is derived, the turbulence can be computed. The effectiveness of the method is first demonstrated in a heated jet where both pressure and temperature are varied. Tests in the turbine facility are performed at turbine inlet temperatures of 480 K. Thus, overheat ratios up to 1.9 had to be used, leading to a very high temperature of the tungsten platinum coated wire. The aging of the probe was very fast, causing a drift in the voltage output between the successive tests. A technique is proposed to minimize the aging effect. It consists in adapting the calibration based on the resistance of the wire measured before each test. Measurements were carried out at the turbine inlet and rotor outlet. At the turbine inlet, velocity radial profiles are obtained together with measurements of the turbulence intensity. The time-averaged data is compared with pneumatic probe measurements. At the rotor exit, the time-resolved periodic velocity fluctuations are analyzed using a phase-locked average technique.
[1]
Leroy H. Smith,et al.
Wake Dispersion in Turbomachines
,
1966
.
[2]
F A Koch,et al.
Temperature effects on hot wire anemometer calibrations
,
1972
.
[3]
H. Hodson.
Measurements of wake-generated unsteadiness in the rotor passages of axial flow turbines
,
1985
.
[4]
Friedrich Kost,et al.
Investigation of the Unsteady Rotor Flow Field in a Single HP Turbine Stage
,
2000
.
[5]
J. Woisetschläger,et al.
Stereoscopic particle image velocimetry in a transonic turbine stage
,
2002
.
[6]
Ivor Day.
Stall inception in axial flow compressors
,
1993
.
[7]
H. H. Bruun.
Hot-wire anemometry
,
1995
.
[8]
Ian P. Castro,et al.
Some comments on heat-transfer laws for fine wires
,
1972,
Journal of Fluid Mechanics.
[9]
Cameron Tropea,et al.
On temperature compensation in hot-wire anemometry
,
1987
.
[10]
Collis Dc,et al.
Two-dimensional convection from heated wires at low Reynolds numbers
,
1959,
Journal of Fluid Mechanics.
[11]
Wing Ng,et al.
High‐frequency temperature and pressure probe for unsteady compressible flows
,
1983
.
[12]
C. Gibson,et al.
Detection of conductivity fluctuations in a turbulent flow field
,
1963,
Journal of Fluid Mechanics.
[13]
Louis Vessot King,et al.
On the Convection of Heat from Small Cylinders in a Stream of Fluid: Determination of the Convection Constants of Small Platinum Wires with Applications to Hot-Wire Anemometry
,
1914
.
[14]
Tony Arts,et al.
The VKI Compression Tube Annular Cascade Facility CT3
,
1992
.