Peak skin and eye lens radiation dose from brain perfusion CT: CTDIvol and Monte Carlo based estimations.

[1]  Qing Liang,et al.  Estimating Patient Organ Dose with Computed Tomography: A Review of Present Methodology and Required DICOM Information A Joint Report of AAPM Task Group 246 and the European Federation of Organizations for Medical Physics (EFOMP) , 2019 .

[2]  Ernst J. Rummeny,et al.  Radiation dose reduction in perfusion CT imaging of the brain using a 256-slice CT: 80 mAs versus 160 mAs. , 2018, Clinical imaging.

[3]  Konstantin Nikolaou,et al.  Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature. , 2016, Journal of neuroradiology. Journal de neuroradiologie.

[4]  R. Joemai,et al.  Perfusion CT of the Brain and Liver and of Lung Tumors: Use of Monte Carlo Simulation for Patient Dose Estimation for Examinations With a Cone-Beam 320-MDCT Scanner. , 2016, AJR. American journal of roentgenology.

[5]  G. Brix,et al.  Radiation protection issues in dynamic contrast-enhanced (perfusion) computed tomography. , 2015, European journal of radiology.

[6]  M. Arreola,et al.  Determining Organ Doses from CT with Direct Measurements in Postmortem Subjects: Part 1--Methodology and Validation. , 2015, Radiology.

[7]  William Pavlicek,et al.  How I do it: managing radiation dose in CT. , 2014, Radiology.

[8]  Hilde Bosmans,et al.  Implementing the complete beam hardening effect of the bowtie filter versus scaling beam intensities: effects on dosimetric applications in computed tomography , 2014, Journal of medical imaging.

[9]  K. Chakrabarti,et al.  Experimental estimates of peak skin dose and its relationship to the CT dose index using the CTDI head phantom. , 2013, Radiation protection dosimetry.

[10]  Ehsan Samei,et al.  Estimation of radiation exposure for brain perfusion CT: standard protocol compared with deviations in protocol. , 2013, AJR. American journal of roentgenology.

[11]  R. Padovani,et al.  Radiation doses in cerebral perfusion computed tomography: patient and phantom study. , 2013, Radiation protection dosimetry.

[12]  Cynthia H McCollough,et al.  Peak skin and eye lens radiation dose from brain perfusion CT based on Monte Carlo simulation. , 2012, AJR. American journal of roentgenology.

[13]  J H Hendry,et al.  ICRP PUBLICATION 118: ICRP Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs — Threshold Doses for Tissue Reactions in a Radiation Protection Context , 2012, Annals of the ICRP.

[14]  H. Bosmans,et al.  Effective dose range for dental cone beam computed tomography scanners. , 2012, European journal of radiology.

[15]  H. Bosmans,et al.  Excess radiation and organ dose in chest and abdominal CT due to CT acquisition beyond expected anatomical boundaries , 2012, European Radiology.

[16]  F. Diekmann,et al.  Dose Exposure of Patients Undergoing Comprehensive Stroke Imaging by Multidetector-Row CT: Comparison of 320-Detector Row and 64-Detector Row CT Scanners , 2010, American Journal of Neuroradiology.

[17]  S. Furui,et al.  Lens Exposure during Brain Scans Using Multidetector Row CT Scanners: Methods for Estimation of Lens Dose , 2010, American Journal of Neuroradiology.

[18]  M Wintermark,et al.  FDA Investigates the Safety of Brain Perfusion CT , 2010, American Journal of Neuroradiology.

[19]  Cynthia H McCollough,et al.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations. , 2009, Medical physics.

[20]  M Cohnen,et al.  Radiation exposure of patients in comprehensive computed tomography of the head in acute stroke. , 2006, AJNR. American journal of neuroradiology.

[21]  I. Kawrakow,et al.  History by history statistical estimators in the BEAM code system. , 2002, Medical physics.