Mitral Annular Dynamics in Myxomatous Valve Disease: New Insights With Real-Time 3-Dimensional Echocardiography

Background— Mitral annulus is a complex structure of poorly understood physiology. Full-volume real-time 3-dimensional transesophageal echocardiography offers a unique opportunity to completely image and quantify mitral annulus size and motion. Methods and Results— Real-time 3-dimensional transesophageal echocardiography of the mitral valve was acquired in 32 patients with myxomatous valve disease (MVD) and moderate to severe regurgitation, 15 normal control subjects, and 10 patients with ischemic mitral regurgitation of identical body surface area. Mitral annular dimensions (circumference, area, anteroposterior and intercommissural diameters, height, and ratio of height to intercommissural diameter ratio, which appraises annular saddle-shape depth) were measured throughout the cardiac cycle with dedicated quantification software. Compared with direct surgical measurement, 3-dimensional anterior annular dimension provided reliable measurements (mean difference, 0.1±0.1 mm; P=0.73; 95% confidence interval, ±4.4 mm). Annular dimensions were larger in MVD patients compared with control subjects in diastole (all P<0.05). Normal annulus displayed early-systolic anteroposterior (P<0.001) and area (P=0.04) contraction, increased height (P<0.001), and deeper saddle shape (ratio of height to intercommissural diameter, 15±1% to 21±1%; P<0.001), whereas intercommissural diameter was unchanged (P=0.30). In contrast, MVD showed early-systolic intercommissural dilatation (P=0.02) and no area contraction (P=0.99), height increase (P=0.11), or saddle-shape deepening (P=0.35). Late-systolic MVD annular saddle shape deepened but annular area excessively enlarged (P<0.04) as a result of persistent intercommissural widening (P<0.02). MVD annulus also contrasts with ischemic mitral regurgitation annulus, which, despite similar anteroposterior enlargement, is narrower and essentially adynamic. After MVD repair, the annulus remained dynamic without systolic saddle-shape accentuation (P=0.30). Conclusions— Real-time 3-dimensional transesophageal echocardiography provides insights into normal, dynamic mitral annulus function with early-systolic area contraction and saddle-shape deepening contributing to mitral competency. MVD annulus is also dynamic but considerably different with loss of early-systolic area contraction and saddle-shape deepening despite similar magnitude of ventricular contraction, suggestive of ventricular-annular decoupling. Subsequent area enlargement may contribute to mitral incompetence. After mitral repair, MVD annulus remains dynamic without systolic saddle-shape accentuation. Thus, real-time 3-dimensional transesophageal echocardiography provides new insights that allow the refining of mitral pathophysiology concepts and repair strategies.

[1]  R. Levine,et al.  In Vivo Measurement of Mitral Leaflet Surface Area and Subvalvular Geometry in Patients With Asymmetrical Septal Hypertrophy: Insights Into the Mechanism of Outflow Tract Obstruction , 2010, Circulation.

[2]  P. D. del Nido,et al.  In Vitro Characterization of the Mechanisms Responsible for Functional Tricuspid Regurgitation , 2011, Circulation.

[3]  G. Hutchins,et al.  The association of floppy mitral valve with disjunction of the mitral annulus fibrosus. , 1986, The New England journal of medicine.

[4]  Ischemic Mitral Regurgitation Long-Term Outcome and Prognostic Implications With Quantitative Doppler Assessment , 2001 .

[5]  C. Herzog,et al.  Survival of Kidney Transplantation Patients in the United States After Cardiac Valve Replacement , 2010, Circulation.

[6]  J. Marshall,et al.  Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse. , 1989, Circulation.

[7]  Victor Mor-Avi,et al.  Characterization of Degenerative Mitral Valve Disease Using Morphologic Analysis of Real-Time Three-Dimensional Echocardiographic Images: Objective Insight Into Complexity and Planning of Mitral Valve Repair , 2011, Circulation. Cardiovascular imaging.

[8]  M. Enriquez-Sarano,et al.  Mitral Valve Diseases , 2007 .

[9]  J. Gummert,et al.  Survival Comparison of the Ross Procedure and Mechanical Valve Replacement With Optimal Self-Management Anticoagulation Therapy: Propensity-Matched Cohort Study , 2011, Circulation.

[10]  D. Attias,et al.  Prevalence, Characteristics, and Outcomes of Patients Presenting With Cardiogenic Unilateral Pulmonary Edema , 2010, Circulation.

[11]  Reconsideration of echocardiographic standards for mitral valve prolapse: lack of association between leaflet displacement isolated to the apical four chamber view and independent echocardiographic evidence of abnormality. , 1988, Journal of the American College of Cardiology.

[12]  M. Enriquez-Sarano,et al.  Survival advantage and improved durability of mitral repair for leaflet prolapse subsets in the current era. , 2006, The Annals of thoracic surgery.

[13]  R. Levine,et al.  Relief of Mitral Leaflet Tethering Following Chronic Myocardial Infarction by Chordal Cutting Diminishes Left Ventricular Remodeling , 2010, Circulation. Cardiovascular imaging.

[14]  T. Denney,et al.  Chymase Inhibition Prevents Fibronectin and Myofibrillar Loss and Improves Cardiomyocyte Function and LV Torsion Angle in Dogs With Isolated Mitral Regurgitation , 2010, Circulation.

[15]  Jeroen J. Bax,et al.  Cardiac Resynchronization Therapy as a Therapeutic Option in Patients With Moderate-Severe Functional Mitral Regurgitation and High Operative Risk , 2011, Circulation.

[16]  R C Gorman,et al.  Dynamic three-dimensional imaging of the mitral valve and left ventricle by rapid sonomicrometry array localization. , 1996, The Journal of thoracic and cardiovascular surgery.

[17]  C. Tei,et al.  Size and Motion of the Mitral Valve Annulus in Man: I. A Two‐dimensional Echocardiographic Method and Findings in Normal Subjects , 1981, Circulation.

[18]  J. Cheatham,et al.  Short-Term Performance of the Transcatheter Melody Valve in High-Pressure Hemodynamic Environments in the Pulmonary and Systemic Circulations , 2011, Circulation. Cardiovascular interventions.

[19]  Neil B. Ingels,et al.  Annular Height-to-Commissural Width Ratio of Annulolasty Rings In Vivo , 2005, Circulation.

[20]  R. Virmani,et al.  Pathological Healing Response of Explanted MitraClip Devices , 2011, Circulation.

[21]  C. Tei,et al.  Size and Motion of the Mitral Valve Annulus in Man: II. Abnormalities in Mitral Valve Prolapse , 1982, Circulation.

[22]  Ronen Gurvitch,et al.  Transcatheter Valve-in-Valve Implantation for Failed Bioprosthetic Heart Valves , 2010, Circulation.

[23]  S. Yun,et al.  Early Surgery Versus Conventional Treatment in Asymptomatic Very Severe Aortic Stenosis , 2010, Circulation.

[24]  S. Göktepe,et al.  Anterior Mitral Leaflet Curvature During the Cardiac Cycle in the Normal Ovine Heart , 2010, Circulation.

[25]  J. Llorca,et al.  Combined Mitral and Tricuspid Valve Repair in Rheumatic Valve Disease: Fewer Reoperations With Prosthetic Ring Annuloplasty , 2010, Circulation.

[26]  B. Chow,et al.  Effects of Mitral Valve Surgery on Myocardial Energetics in Patients With Severe Mitral Regurgitation , 2010, Circulation. Cardiovascular imaging.

[27]  B. Griffin,et al.  Glycosaminoglycan profiles of myxomatous mitral leaflets and chordae parallel the severity of mechanical alterations. , 2003, Journal of the American College of Cardiology.

[28]  T. Sundt,et al.  Spectrum and Outcome of Reoperations After the Ross Procedure , 2010, Circulation.

[29]  A. Bolger,et al.  Geometric determinants of ischemic mitral regurgitation. , 1997, Circulation.

[30]  A. Taylor,et al.  Features of Carcinoid Heart Disease Identified by 2- and 3-Dimensional Echocardiography and Cardiac MRI , 2010, Circulation. Cardiovascular imaging.

[31]  A. Carpentier,et al.  Cardiac valve surgery--the "French correction". , 1983, The Journal of thoracic and cardiovascular surgery.

[32]  K. Hirata,et al.  Dobutamine-Induced Improvement in Inferior Myocardial Contractile Function Predicts Reduction in Functional Mitral Regurgitation: A Study Using Tissue Doppler Strain Rate Imaging , 2010, Circulation. Cardiovascular imaging.

[33]  M. Enriquez-Sarano,et al.  Left Atrial Size Is a Potent Predictor of Mortality in Mitral Regurgitation Due to Flail Leaflets: Results From a Large International Multicenter Study , 2011, Circulation. Cardiovascular imaging.

[34]  W Ameling,et al.  Analysis of shape and motion of the mitral annulus in subjects with and without cardiomyopathy by echocardiographic 3-dimensional reconstruction. , 2000, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[35]  T. Akasaka,et al.  Three-dimensional analysis of configuration and dynamics in patients with an annuloplasty ring by multiplane transesophageal echocardiography: comparison between flexible and rigid annuloplasty rings. , 1995, The Journal of heart valve disease.

[36]  G Bashein,et al.  Three-dimensional echocardiographic assessment of annular shape changes in the normal and regurgitant mitral valve. , 2000, American heart journal.

[37]  W. Manning,et al.  Mitral valve abnormalities identified by cardiovascular magnetic resonance represent a primary phenotypic expression of hypertrophic cardiomyopathy , 2010, Circulation.

[38]  F. Bowen,et al.  Effect of Annular Shape on Leaflet Curvature in Reducing Mitral Leaflet Stress , 2002, Circulation.

[39]  M. Enriquez-Sarano,et al.  Very Long-Term Survival and Durability of Mitral Valve Repair for Mitral Valve Prolapse , 2001, Circulation.

[40]  J. Oh,et al.  Echocardiographic Variables After Left Ventricular Assist Device Implantation Associated With Adverse Outcome , 2011, Circulation. Cardiovascular imaging.

[41]  S. Balasundaram,et al.  Surgical Approaches to the Mitral Valve , 1990, Journal of cardiac surgery.

[42]  W. Strohsnitter,et al.  Anomalous Mitral Arcade in Twin-Twin Transfusion Syndrome , 2010, Circulation.

[43]  A. Bolger,et al.  Most ovine mitral annular three-dimensional size reduction occurs before ventricular systole and is abolished with ventricular pacing. , 1997, Circulation.

[44]  Richard B Devereux,et al.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardio , 2005, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[45]  C Di Mario,et al.  Coronary stenting after rotational atherectomy in calcified and complex lesions. Angiographic and clinical follow-up results. , 1997, Circulation.

[46]  R. Levine,et al.  Mechanism of Recurrent Ischemic Mitral Regurgitation After Annuloplasty: Continued LV Remodeling as a Moving Target , 2004, Circulation.

[47]  M. Bourgeois,et al.  Size and motion of the mitral valve annulus in anesthetized intact dogs. , 1971, Journal of applied physiology.

[48]  L. Pierard,et al.  Exercise Pulmonary Hypertension in Asymptomatic Degenerative Mitral Regurgitation , 2010, Circulation.

[49]  R. Siegel,et al.  Mechanisms of Acute Mitral Regurgitation in Patients With Takotsubo Cardiomyopathy: An Echocardiographic Study , 2011, Circulation. Cardiovascular imaging.

[50]  D. Ross,et al.  Direct Transthoracic Access to the Left Ventricle for Catheter Ablation of Ventricular Tachycardia , 2010, Circulation. Arrhythmia and electrophysiology.

[51]  J B Seward,et al.  Determinants of the Degree of Functional Mitral Regurgitation in Patients With Systolic Left Ventricular Dysfunction: A Quantitative Clinical Study , 2000, Circulation.

[52]  Daniel B Ennis,et al.  Changes in Mitral Annular Geometry and Dynamics With &bgr;-Blockade in Patients With Degenerative Mitral Valve Disease , 2010, Circulation. Cardiovascular imaging.

[53]  B. Popescu,et al.  Effect of Hydroxymethylglutaryl Coenzyme-A Reductase Inhibitors on the Long-Term Progression of Rheumatic Mitral Valve Disease , 2010, Circulation.

[54]  Robert C Gorman,et al.  The effect of regional ischemia on mitral valve annular saddle shape. , 2004, The Annals of thoracic surgery.