Comparison of sparse domain approaches for 4D SPECT dynamic image reconstruction

PURPOSE Dynamic imaging (DI) provides additional diagnostic information in emission tomography in comparison to conventional static imaging at the cost of being computationally more challenging. Dynamic single photon emission computed tomography (SPECT) reconstruction is particularly difficult because of the limitations in the sampling geometry present in most existing scanners. We have developed an algorithm Spline Initialized Factor Analysis of Dynamic Structures (SIFADS) that is a matrix factorization method for reconstructing the dynamics of tracers in tissues and blood directly from the projections in dynamic cardiac SPECT, without first resorting to any 3D reconstruction. METHODS SIFADS is different from "pure" factor analysis in dynamic structures (FADS) in that it employs a dedicated spline-based pre-initialization. In this paper, we analyze the convergence properties of SIFADS and FADS using multiple metrics. The performances of the two approaches are evaluated for numerically simulated data and for real dynamic SPECT data from canine and human subjects. RESULTS For SIFADS, metrics analyzed for reconstruction algorithm convergence show better features of the metric curves vs iterations. In addition, SIAFDS provides better tissue segmentations than that from pure FADS. Measured computational times are also typically better for SIFADS implementations than those with pure FADS. CONCLUSION The analysis supports the utility of the pre-initialization of a factorization algorithm for better dynamic SPECT image reconstruction.

[1]  H. Sebastian Seung,et al.  Learning the parts of objects by non-negative matrix factorization , 1999, Nature.

[2]  G. Gullberg,et al.  Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  Osamu Okazaki,et al.  Long fasting is effective in inhibiting physiological myocardial 18F-FDG uptake and for evaluating active lesions of cardiac sarcoidosis , 2014, EJNMMI Research.

[4]  G. Gullberg,et al.  4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior. , 2001, Physics in medicine and biology.

[5]  Yongyi Yang,et al.  Effects of motion, attenuation, and scatter corrections on gated cardiac SPECT reconstruction. , 2011, Medical physics.

[6]  Grant T Gullberg,et al.  Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation , 2015, Journal of Nuclear Cardiology.

[7]  H. S. Khare,et al.  Compartmental Modeling of Technetium-99m—Labeled Teboroxime with Dynamic Single-Photon Emission Computed Tomography: Comparison with Static Thallium-201 in a Canine Model , 2001, Investigative radiology.

[8]  Grant T Gullberg,et al.  Image reconstruction in higher dimensions: myocardial perfusion imaging of tracer dynamics with cardiac motion due to deformation and respiration , 2015, Physics in medicine and biology.

[9]  Debasis Mitra,et al.  Reconstruction of 4-D Dynamic SPECT Images From Inconsistent Projections Using a Spline Initialized FADS Algorithm (SIFADS) , 2015, IEEE Transactions on Medical Imaging.

[10]  E. Levitan,et al.  A Maximum a Posteriori Probability Expectation Maximization Algorithm for Image Reconstruction in Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[11]  Grant T Gullberg,et al.  A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT , 2017, Journal of Nuclear Cardiology.

[12]  Michael Elad,et al.  Sparse and Redundant Modeling of Image Content Using an Image-Signature-Dictionary , 2008, SIAM J. Imaging Sci..

[13]  Debasis Mitra,et al.  Clustering-Initiated Factor Analysis Application for Tissue Classification in Dynamic Brain Positron Emission Tomography , 2015, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[14]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[15]  S. Eberl,et al.  Optimized acquisition time and image sampling for dynamic SPECT of Tl-201 , 1998, IEEE Transactions on Medical Imaging.

[16]  Mahmoud Abdalah 4D Dynamic Image Reconstruction for Cardiac SPECT , 2014 .

[17]  Ronald H. Huesman,et al.  Correction for ambiguous solutions in factor analysis using a penalized least squares objective , 2002, IEEE Transactions on Medical Imaging.

[18]  M. King,et al.  Reconstruction of dynamic gated cardiac SPECT. , 2006 .

[19]  A. Celler,et al.  Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing activity changes. , 2000, Physics in medicine and biology.

[20]  W. Rogers,et al.  Compartmental analysis of technetium-99m-teboroxime kinetics employing fast dynamic SPECT at rest and stress. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  Grant T Gullberg,et al.  Dynamic single photon emission computed tomography—basic principles and cardiac applications , 2010, Physics in medicine and biology.

[22]  R. Huesman,et al.  Direct least-squares estimation of spatiotemporal distributions from dynamic SPECT projections using a spatial segmentation and temporal B-splines , 2000, IEEE Transactions on Medical Imaging.

[23]  Lei Wang,et al.  Avoiding full corrections in dynamic SPECT images impacts the performance of SPECT myocardial blood flow quantitation , 2017, Journal of Nuclear Cardiology.

[24]  E R Carson,et al.  Use of kinetic analysis and mathematical modeling in the study of metabolic pathways in vivo: applications to hepatic organic anion metabolism (second of two parts). , 1979, The New England journal of medicine.

[25]  Brian F. Hutton,et al.  What are the necessary corrections for dynamic cardiac SPECT? , 2016, Journal of Nuclear Cardiology.

[26]  A. Celler,et al.  Simultaneous assessment of cardiac perfusion and function using 5-dimensional imaging with Tc-99m teboroxime , 2006, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[27]  Wen-Sheng Huang,et al.  Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease , 2014, European Journal of Nuclear Medicine and Molecular Imaging.

[28]  Adam M. Oberman,et al.  Anisotropic Total Variation Regularized L^1-Approximation and Denoising/Deblurring of 2D Bar Codes , 2010, 1007.1035.

[29]  Wen-Sheng Huang,et al.  Feasibility and operator variability of myocardial blood flow and reserve measurements with 99mTc-sestamibi quantitative dynamic SPECT/CT imaging , 2014, Journal of Nuclear Cardiology.

[30]  Debasis Mitra,et al.  SinoCor: Inter-frame and intra-frame motion correction tool , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[31]  Jones Ea,et al.  Use of Kinetic Analysis and Mathematical Modeling in the Study of Metabolic Pathways in Vivo: Applications to Hepatic Organic Anion Metabolism , 1979 .

[32]  Denis Mariano-Goulart,et al.  SPECT Myocardial Perfusion Reserve in Patients with Multivessel Coronary Disease: Correlation with Angiographic Findings and Invasive Fractional Flow Reserve Measurements , 2015, The Journal of Nuclear Medicine.

[33]  Lei Zhang,et al.  Sparsity-based image denoising via dictionary learning and structural clustering , 2011, CVPR 2011.

[34]  W. Segars,et al.  4D XCAT phantom for multimodality imaging research. , 2010, Medical physics.

[35]  Grant T Gullberg,et al.  Myocardial blood flow measurement with a conventional dual-head SPECT/CT with spatiotemporal iterative reconstructions - a clinical feasibility study. , 2013, American journal of nuclear medicine and molecular imaging.

[36]  Kazufumi Ito,et al.  A Regularization Parameter for Nonsmooth Tikhonov Regularization , 2011, SIAM J. Sci. Comput..

[37]  P. Slomka,et al.  Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study , 2013, The Journal of Nuclear Medicine.

[38]  J. Branham,et al.  Alternatives to least squares , 1982 .

[39]  E R Carson,et al.  Use of kinetic analysis and mathematical modeling in the study of metabolic pathways in vivo. Applications to hepatic organic anion metabolism. (First of two parts). , 2010, The New England journal of medicine.

[40]  H. Zaidi,et al.  Tracer Kinetic Modeling in Nuclear Medicine: Theory and Applications , 2006 .

[41]  Ran Klein,et al.  Dynamic SPECT Measurement of Absolute Myocardial Blood Flow in a Porcine Model , 2014, The Journal of Nuclear Medicine.

[42]  G. Gullberg,et al.  Factor analysis with a priori knowledge--application in dynamic cardiac SPECT. , 2000, Physics in medicine and biology.

[43]  G. Gullberg,et al.  Fast direct estimation of the blood input function and myocardial time activity curve from dynamic SPECT projections via reduction in spatial and temporal dimensions. , 2013, Medical physics.

[44]  R. Huesman,et al.  Removal of liver activity contamination in teboroxime dynamic cardiac SPECT imaging with the use of factor analysis , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[45]  Grant T Gullberg,et al.  Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies , 2012, Physics in medicine and biology.

[46]  A. Celler,et al.  Dynamic SPECT imaging using a single camera rotation (dSPECT) , 1999 .

[47]  D. Okada,et al.  Myocardial clearance of technetium-99m-teboroxime in reperfused injured canine myocardium , 2014, EJNMMI Research.

[48]  R. Huesman,et al.  Effects of temporal modelling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections , 2002 .