Determination of the primary structure of peptides using fast atom bombardment mass spectrometry.

The determination of the amino acid composition and sequence of a peptide, using both conventional and tandem fast atom bombardment mass spectrometry, is presented. First a list of potential empirical formulae is generated using the accurate mass and isotopic peak intensity ratios from the molecular ion cluster. The formulae are mathematically analyzed to ensure that they correspond to linear peptides composed of 19 common amino acids. Then using the ions below m/z 160 Da, which are characteristic of the amino acid content of the peptide, the formulae are decomposed into possible amino acid compositions. From each composition sequences are generated and their predicted fragment ions are compared to ions present in the mass spectrum. A score based on the intensities and the occurrence of consecutive sequence fragments is calculated. Finally sequences with the ten highest scores are retained. Analyses performed on typical peptides with molecular weights below 1500 Da indicate that identification can generally be achieved using this approach.

[1]  B. Bentz,et al.  Characterization of organic dyes aided by hydrogen-deuterium exchange in liquid secondary ion mass spectrometry (liquid SIMS) , 1987 .

[2]  Dudley H. Williams Application of fast atom bombardment mass spectrometry to structural problems in organic chemistry , 1983 .

[3]  P. Thibault,et al.  Determination of the empirical formula of peptides by fast atom bombardment mass spectrometry. , 1987, Biomedical & environmental mass spectrometry.

[4]  P. Højrup,et al.  Evaluation of fast atom bombardment mass spectrometry for sequence determination of peptides , 1985 .

[5]  P. Thibault,et al.  Charge inversion spectra of the [M − H]− ions of Di- and polypeptides analyzed by fast atom bombardment mass spectrometry , 1986 .

[6]  J. C. Bill,et al.  Fast atom bombardment (FAB) mass spectrometry: a mass spectral investigation of some of the insulins. , 1984, Biomedical mass spectrometry.

[7]  W. V. Ligon,et al.  The secondary ion mass spectrum of glycerol-d5: Evidence for radical cation intermediates , 1983 .

[8]  T. Sakurai,et al.  Mass distribution of peptide molecular ions in the secondary ionization process , 1985 .

[9]  T. Sakurai,et al.  Improved PAAS, a computer program to determine possible amino acid sequences of peptides , 1983 .

[10]  S. Unger,et al.  Structure of the quinone antibiotic EM5519 and the behavior of quinones in fast atom bombardment mass spectrometry. , 1985, The Journal of antibiotics.

[11]  Dudley H. Williams,et al.  Aspects of the production of FAB and SIMS mass spectra , 1987 .

[12]  A. Burlingame,et al.  Secondary ion mass spectrometry with cesium ion primary beam and liquid target matrix for analysis of bioorganic compounds , 1982 .

[13]  K. Ishikawa,et al.  Computer-aided peptide sequencing by fast atom bombardment mass spectrometry , 1986 .

[14]  H. Beckey,et al.  Field desorption mass spectrometry of peptides. , 1972, Biochemical and biophysical research communications.

[15]  F. H. Field,et al.  Fast atom bombardment study of glycerol: mass spectra and radiation chemistry , 1982 .

[16]  Y. Shimonishi,et al.  Sequencing of peptide mixtures by Edman degradation and field-desorption mass spectrometry. , 1980, European journal of biochemistry.

[17]  P. Roepstorff,et al.  Proposal for a common nomenclature for sequence ions in mass spectra of peptides. , 1984, Biomedical mass spectrometry.

[18]  M. Waterfield,et al.  Quantitative Approach to the Sequential Degradation of Proteins and Peptides , 1969, Nature.

[19]  M. Barber,et al.  Fast atom bombardment mass spectrometry of the angiotensin peptides. , 1982, Biomedical mass spectrometry.

[20]  K. Biemann,et al.  A graphics display-oriented strategy for the amino acid sequencing of peptides by tandem mass spectrometry , 1987 .

[21]  Stephen A. Martin,et al.  Mass spectrometric determination of the amino acid sequence of peptides and proteins , 1987 .

[22]  K. Biemann,et al.  Determination of the amino acid sequence in oligopeptides by computer interpretation of their high-resolution mass spectra. , 1966, Journal of the American Chemical Society.

[23]  B. Musselman,et al.  Observation of solvent effects on abundance of polyhydrogen adducts (M + nH)+ in fast atom bombardment mass spectrometry. , 1987, Biomedical & environmental mass spectrometry.

[24]  K. Biemann,et al.  Quantitative amino acid analysis by mass spectrometry. , 1960 .

[25]  R. Macfarlane,et al.  252Cf-plasma desorption time-of-flight mass spectrometry☆ , 1976 .

[26]  M. Gross,et al.  Abundances of molecular ion species desorbed by fast atom bombardment: observation of (M + 2H)+.cntdot. and (M + 3H)+.cntdot. , 1985 .

[27]  L. Deterding,et al.  Design of a coaxial continuous flow fast atom bombardment probe , 1988 .

[28]  M. Goto,et al.  Direct coupling of micro high-performance liquid chromatography with fast atom bombardment mass spectrometry , 1985 .

[29]  F. McLafferty,et al.  Mass spectrometric studies of peptides. 3. Automated determination of amino acid sequences. , 1966, Journal of the American Chemical Society.

[30]  W. T. Moore,et al.  Microbore HPLC/mass spectrometry for the analysis of peptide mixtures using a continuous flow interface. , 1987, Biochemical and biophysical research communications.

[31]  L. Taylor,et al.  The use of signal averaging techniques for the quantitation and mass measurement of high molecular weight compounds using fast atom bombardment mass spectrometry , 1985 .

[32]  H. Naoki,et al.  Sequence analysis for an unknown peptide by molecular secondary ion mass spectrometry , 1985 .

[33]  F. Richards,et al.  Sequence analysis of complex protein mixtures by isotope dilution and mass spectrometry. , 1970, Biochemistry.

[34]  B. E. Amrani,et al.  Characterization of leucine and isoleucine by use of the FAB ionization method in tandem mass spectrometry , 1985 .

[35]  N Bauman,et al.  An efficient algorithm for sequencing peptides using fast atom bombardment mass spectral data. , 1988, Biomedical & environmental mass spectrometry.

[36]  P. Thibault,et al.  Mass spectrometry of domoic acid, a marine neurotoxin , 1989 .

[37]  R. Caprioli,et al.  Continuous-flow sample probe for fast atom bombardment mass spectrometry. , 1986, Analytical chemistry.

[38]  R. March,et al.  A hybrid BEQQ mass spectrometer for studies in gaseous ion chemistry , 1986 .

[39]  C. Koval,et al.  Circuit for optimally matching instrumental output voltage levels to the input voltage levels of analog-to-digital converters , 1985 .