Monte Carlo simulation of novel breast imaging modalities based on coherent x-ray scattering

We present upgraded versions of MC-GPU and penEasy_Imaging, two open-source Monte Carlo codes for the simulation of radiographic projections and CT, that have been extended and validated to account for the effect of molecular interference in the coherent x-ray scatter. The codes were first validation by comparison between simulated and measured energy dispersive x-ray diffraction (EDXRD) spectra. A second validation was by evaluation of the rejection factor of a focused anti-scatter grid. To exemplify the capabilities of the new codes, the modified MC-GPU code was used to examine the possibility of characterizing breast tissue composition and microcalcifications in a volume of interest inside a whole breast phantom using EDXRD and to simulate a coherent scatter computed tomography (CSCT) system based on first generation CT acquisition geometry. It was confirmed that EDXRD and CSCT have the potential to characterize tissue composition inside a whole breast. The GPU-accelerated code was able to simulate, in just a few hours, a complete CSCT acquisition composed of 9758 independent pencil-beam projections. In summary, it has been shown that the presented software can be used for fast and accurate simulation of novel breast imaging modalities relying on scattering measurements and therefore can assist in the characterization and optimization of promising modalities currently under development.

[1]  M. Säbel,et al.  Recent developments in breast imaging. , 1996, Physics in medicine and biology.

[2]  M. Poletti,et al.  X-ray scattering from human breast tissues and breast-equivalent materials. , 2002, Physics in medicine and biology.

[3]  R. D. Luggar,et al.  Recent developments in industrial applications of elastic scatter X-ray inspection , 1999 .

[4]  R D Speller,et al.  Characterization of breast tissue using energy-dispersive X-ray diffraction computed tomography. , 2010, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[5]  D M Cunha,et al.  Evaluation of scatter-to-primary ratio, grid performance and normalized average glandular dose in mammography by Monte Carlo simulation including interference and energy broadening effects , 2010, Physics in medicine and biology.

[6]  Aldo Badano,et al.  Accelerating Monte Carlo simulations of photon transport in a voxelized geometry using a massively parallel graphics processing unit. , 2009, Medical physics.

[7]  U Neitzel,et al.  X-ray diffraction computed tomography. , 1987, Medical physics.

[8]  M. Morgan,et al.  Phosphocitrate Inhibits Calcium Hydroxyapatite Induced Mitogenesis and Upregulation of Matrix Metalloproteinase-1, Interleukin-1β and Cyclooxygenase-2 mRNA in Human Breast Cancer Cell Lines , 2003, Breast Cancer Research and Treatment.

[9]  R D Speller,et al.  X-ray scatter signatures for normal and neoplastic breast tissues. , 1999, Physics in medicine and biology.

[10]  Geoffrey Harding,et al.  Coherent X-ray scatter imaging and its applications in biomedical science and industry , 1999 .

[11]  G T Barnes,et al.  Contrast and scatter in x-ray imaging. , 1991, Radiographics : a review publication of the Radiological Society of North America, Inc.

[12]  D E Peplow,et al.  Measured molecular coherent scattering form factors of animal tissues, plastics and human breast tissue. , 1998, Physics in medicine and biology.

[13]  M. Groza,et al.  Test of thick pixelated orbotech detectors with and without steering grids , 2006, SPIE Optics + Photonics.

[14]  Kyle J Myers,et al.  X-ray properties of an anthropomorphic breast phantom for MRI and x-ray imaging. , 2011, Physics in medicine and biology.

[15]  J. Sempau,et al.  PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport , 2009 .

[16]  Lingyun Chen,et al.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study. , 2008, Medical physics.

[17]  P C Johns,et al.  X-ray coherent scattering form factors of tissues, water and plastics using energy dispersion. , 2011, Physics in medicine and biology.

[18]  Matthew C. Veale,et al.  Energy dispersive X-ray diffraction computed tomography of breast-simulating phantoms and a tissue sample , 2013, Medical Imaging.

[19]  Ian A Cunningham,et al.  Bone-composition imaging using coherent-scatter computed tomography: assessing bone health beyond bone mineral density. , 2006, Medical physics.

[20]  Robert J LeClair,et al.  A semianalytic model to extract differential linear scattering coefficients of breast tissue from energy dispersive x-ray diffraction measurements. , 2005, Medical physics.

[21]  Loick Verger,et al.  Effect of grain size on stability of X-ray diffraction patterns used for threat detection , 2012 .

[22]  D. A. Bradley,et al.  X-ray fluorescence and energy dispersive X-ray diffraction for the characterisation of breast tissue , 2004 .

[23]  J. H. Hubbell,et al.  Atomic form factors, incoherent scattering functions, and photon scattering cross sections , 1975 .

[24]  D. Bradley,et al.  X-ray fluorescence and energy dispersive x-ray diffraction for the quantification of elemental concentrations in breast tissue. , 2004, Physics in medicine and biology.

[25]  Ricardo Tadeu Lopes,et al.  Coherent scattering characteristics of normal and pathological breast human tissues , 2004 .

[26]  J. Kosanetzky,et al.  Energy-dispersive X-ray diffraction tomography , 1990 .

[27]  O. Gonçalves,et al.  Coherent and incoherent scattering of 17.44 and 6.93 keV x-ray photons scattered from biological and biological-equivalent samples: characterization of tissues , 2002 .

[28]  A Taibi,et al.  Updating of form factor tabulations for coherent scattering of photons in tissues. , 2002, Physics in medicine and biology.

[29]  Geoffrey Harding Effective density and atomic number determined from diffraction profiles , 2006, SPIE Optics + Photonics.

[30]  E. Ryan,et al.  Breast tissue classification using x-ray scattering measurements and multivariate data analysis , 2007, Physics in medicine and biology.

[31]  M. Poletti,et al.  Identification of neoplasias of breast tissues using a powder diffractometer. , 2008, Journal of radiation research.

[32]  A Tomal,et al.  Optimization of x-ray spectra in digital mammography through Monte Carlo simulations , 2012, Physics in medicine and biology.

[33]  A Fenster,et al.  Tomographic imaging of the angular-dependent coherent-scatter cross section. , 1997, Medical physics.