Application of a ground source heat pump system with PCM‐embedded radiant wall heating for buildings

This paper deals with the utilization of a renewable energy‐based integrated system with the latent heat storage option for building thermal management systems. Both energy and exergy‐based assessments of the current combined system are conducted. For this purpose, phase change material (PCM)‐embedded radiant wall heating system using solar heating and ground source heat pump (GSHP) is studied thermodynamically. Heat is essentially stored within the PCMs as used in the panels to increase the effectiveness. The stored heat is released when the solar energy is not available. In the thermal energy storage analyses, four different PCMs are considered. The present results show that the overall first ‐ law (energy) and second ‐ law (exergy) efficiencies of the PCM‐free radiant heating system are much lower than the case with the PCM‐embedded radiant heating system. Therefore, it is confirmed that the energy efficiency increases from 62% to 87% while the exergy efficiency rises from 14% to 56% with the option where SP26E PCM is employed accordingly.

[1]  Hasan Köten,et al.  Energy, exergy and exergoeconomic analysis of solar-assisted vertical ground source heat pump system for heating season , 2018, Journal of Mechanical Science and Technology.

[2]  Ryozo Ooka,et al.  Exergy analysis of a hybrid ground-source heat pump system , 2017 .

[3]  Olcay Kincay,et al.  Exergy, exergoenvironmental and exergoeconomic evaluation of a heat pump-integrated wall heating system , 2016 .

[4]  Yi Xia,et al.  Experimental research on a double-layer radiant floor system with phase change material under heating mode , 2016 .

[5]  Bo Fan,et al.  Evaluation of operation and control in HVAC (heating, ventilation and air conditioning) system using exergy analysis method , 2015 .

[6]  Jing He,et al.  Thermal performance of a radiant floor heating system with different heat storage materials and heating pipes , 2015 .

[7]  Xing Fang,et al.  The method of evaluating operation performance of HVAC system based on exergy analysis , 2014 .

[8]  Ibrahim Dincer,et al.  Exergy analysis and optimization of a thermal management system with phase change material for hybrid electric vehicles , 2014 .

[9]  Ho-Young Kwak,et al.  Thermoeconomic analysis of ground‐source heat pump systems , 2014 .

[10]  Abhijit Date,et al.  In Press) A new house wall system for residential buildings , 2013 .

[11]  Javier Mazo,et al.  Modeling a radiant floor system with Phase Change Material (PCM) integrated into a building simulation tool: Analysis of a case study of a floor heating system coupled to a heat pump , 2012 .

[12]  Alberto Giretti,et al.  Radiant floors integrated with PCM for indoor temperature control , 2011 .

[13]  P. G. Luscuere,et al.  An exergy application for analysis of buildings and HVAC systems , 2010 .

[14]  Adriana Angelotti,et al.  Exergy analysis of renewable energy-based climatisation systems for buildings: A critical view , 2009 .

[15]  Dietrich Schmidt Low Exergy Systems for High-Performance Buildings and Communities , 2009 .

[16]  A. Hepbasli,et al.  Experimental investigation of the performance of a solar‐assisted ground‐source heat pump system for greenhouse heating , 2005 .

[17]  Ibrahim Dincer,et al.  Exergy as a Driver for Achieving Sustainability , 2004 .

[18]  J. Churton Thermal Insulation in Buildings , 1959, Royal Society of Health journal.